• Title/Summary/Keyword: Acoustic parameters

Search Result 849, Processing Time 0.026 seconds

An experimental study on triaxial failure mechanical behavior of jointed specimens with different JRC

  • Tian, Wen-Ling;Yang, Sheng-Qi;Dong, Jin-Peng;Cheng, Jian-Long;Lu, Jia-wei
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.181-195
    • /
    • 2022
  • Roughness and joint inclination angle are the important factors that affect the strength and deformation characteristics of jointed rock mass. In this paper, 3D printer has been employed to make molds firstly, and casting the jointed specimens with different joint roughness coefficient (JRC), and different joint inclination angle (α). Conventional triaxial compression tests were carried out on the jointed specimens, and the influence of JRC on the strength and deformation parameters was analyzed. At the same time, acoustic emission (AE) testing system has been adopted to reveal the AE characteristic of the jointed specimens in the process of triaxial compression. Finally, the morphological of the joint surface was observed by digital three-dimensional video microscopy system, and the relationship between the peak strength and JRC under different confining pressures has been discussed. The results indicate that the existence of joint results in a significant reduction in the strength of the joint specimen, JRC also has great influence on the morphology, quantity and spatial distribution characteristics of cracks. With the increase of JRC, the triaxial compressive strength increase, and the specimen will change from brittle failure to ductile failure.

Optimizing Wavelet in Noise Canceler by Deep Learning Based on DWT (DWT 기반 딥러닝 잡음소거기에서 웨이블릿 최적화)

  • Won-Seog Jeong;Haeng-Woo Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.113-118
    • /
    • 2024
  • In this paper, we propose an optimal wavelet in a system for canceling background noise of acoustic signals. This system performed Discrete Wavelet Transform(DWT) instead of the existing Short Time Fourier Transform(STFT) and then improved noise cancellation performance through a deep learning process. DWT functions as a multi-resolution band-pass filter and obtains transformation parameters by time-shifting the parent wavelet at each level and using several wavelets whose sizes are scaled. Here, the noise cancellation performance of several wavelets was tested to select the most suitable mother wavelet for analyzing the speech. In this study, to verify the performance of the noise cancellation system for various wavelets, a simulation program using Tensorflow and Keras libraries was created and simulation experiments were performed for the four most commonly used wavelets. As a result of the experiment, the case of using Haar or Daubechies wavelets showed the best noise cancellation performance, and the mean square error(MSE) was significantly improved compared to the case of using other wavelets.

Study for Correlation between Objective and Subjective Voice Parameters in Patients with Dysphonia (발성장애 환자에서 주관적 음성검사와 객관적 음성검사의 연관성 연구)

  • Park, Jung Woo;Kim, Boram;Oh, Jae Hwan;Kang, Tae Kyu;Kim, Dong Young;Woo, Joo Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.118-123
    • /
    • 2019
  • Background and Objectives Voice evaluation is classified into subjective tests such as auditory perception and self-measurement, and objective tests such as acoustic and aerodynamic analysis. When evaluating dysphonia, subjective and objective test results do not always match. The purpose of this study was to analyze the relationship between subjective and objective evaluation in patients with dysphonia and to identify meaningful parameters by disease. Materials and Method The total of 322 patients who visited voice clinic from May 2017 to May 2018 were included in this study. Laryngeal lesions were identified using stroboscopy. Pearson correlation test was performed to analyse correlation between subjective tests including GRBAS scale and voice handicap index, and objective tests including jitter, shimmer, noise to harmonic ratio (NHR), cepstral peak prominence (CPP), maximal phonation time (MPT), mean flow rate, and subglottic pressure. Results In vocal nodule and sulcus vocalis, among GRBAS system, grade and breathiness showed good correlation with CPP, and roughness showed good correlation with jitter or shimmer. In unilateral vocal cord paralysis (UVCP), grade and breathiness showed a very good correlation with CPP, and also good correlation with jitter, shimmer, NHR, and MPT. Also asthenia showed good correlation with CPP and MPT. Vocal polyp has a limited association with other diseases. Conclusion In patients with dysphonia, grade and breathiness showed good correlation with CPP, jitter, and shimmer, and reflect the state of voice change well especially in UVCP, CPP, and MPT.

Lamb Wave Technique for Ultrasonic Nonlinear Characterization in Elastic Plates (판재의 초음파 비선형 특성평가를 위한 Lamb Wave 기법)

  • Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.458-463
    • /
    • 2010
  • Since the acoustic nonlinearity is sensitive to the minute variation of material properties, the nonlinear ultrasonic technique(NUT) has been considered as a promising method to evaluate the material degradation or fatigue. However, there are certain limitations to apply the conventional NUT using the bulk wave to thin plates. In case of plates, the use of Lamb wave can be considered, however, the propagation characteristics of Lamb wave are completely different with the bulk wave, and thus the separate study for the nonlinearity of Lamb wave is required. For this work, this paper analyzed first the conditions of mode pair suitable for the practical application as well as for the cumulative propagation of quadratic harmonic frequency and summarized the result in for conditions; (1) phase matching, (2) non-zero power flux, (3) group velocity matching, and (4) non-zero out-of-plane displacement. Experimental results in aluminum plates showed that the amplitude of the secondary Lamb wave and nonlinear parameter growed up with increasing propagation distance at the mode pair satisfying the above all conditions and that the ration of nonlinear parameters measured in Al6061-T6 and Al1100-H15 was closed to the ratio of the absolute nonlinear parameters.

Study on the Fatigue Crack Behavior by the Stress Intensity Factor and AE Parameters (응력확대계수와 음향방출 변수를 이용한 피로균열 거동 연구)

  • Yoon, Dong-Jin;Jeong, Jung-Chae;Park, Phi-Lip;Kim, Ki-Bok;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.412-423
    • /
    • 2000
  • By using the relation between stress intensity factor and AE parameter, new approach method for assessing the crack length and detectability of crack was proposed. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. As a result, the features of specific parameter such as the length of crack growth the AE energy, the AE peak amplitude, and the cumulative AE hits, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a larger number of AE counts. If we can get more reliable database for the relation between AE parameters and stress intensity factor, this approach will provide a good information for evaluating both the existence of crack and the minimum detectable size of crack.

  • PDF

Gas Hydrate Exploration Using LWD/MWD in the Ulleung Basin, the East Sea of Korea (LWD/MWD를 이용한 동해 울릉분지 가스하이드레이트 탐사)

  • Kim, Gil-Young;Yoo, Dong-Geun;Kim, Won-Sik;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.263-270
    • /
    • 2008
  • The Gas Hydrate Research and Development Organization (KGHDO) of Korea accomplished successfully geophysical logging (LWD: Logging While Drilling, MWD: Measurement While Drilling) for five sites in 2007, in order to investigate the presence of gas hydrate in the Ulleung Basin, the East Sea of Korea. The togging parameters acquired from LWD/MWD dre electrical resistivity, acoustic velocity, neutron density and porosity, and natural gamma. In addition, pressure, temperature, and diameter of borehole were measured. LWD/MWD data showed several evidences indicating the presence of gas hydrate. Based on LWD/MWD data, three coring sites were selected for sampling of gas hydrate. Subsequently, various gas hydrate samples were collected directly from three sites. Therefore. the presence of gas hydrates was verified by coring. LWD/MWD data will be significantly used to estimate the amount of gas hydrate. Also, they will provide important information to elucidate about sedimentologic characteristics of gas-hydrate bearing formation and sedimentary environment of the Ulleung Basin.

Inverse Estimation of Geoacoustic Parameters in Shallow Water Using tight Bulb Sound Source (천해환경에서 전구음원을 이용한 지음향인자의 역추정)

  • 한주영;이성욱;나정열;김성일
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.8-16
    • /
    • 2004
  • An inversion method is presented for the determination of the compressional wave speed, compressional wave attenuation, thickness of the sediment layer and density as a function of depth for a horizontally stratified ocean bottom. An experiment for estimating those properties was conducted in the shallow water of South Sea in Korea. In the experiment, a light bulb implosion and the propagating sound were measured using a VLA (vertical line array). As a method for estimating the geoacoustic properties, a coherent broadband matched field processing combined with Genetic Algorithm was employed. When a time-dependent signal is very short, the Fourier transform results are not accurate, since the frequency components are not locatable in time and the windowed Fourier transform is limited by the length of the window. However, it is possible to do this using the wavelet transform a transform that yields a time-frequency representation of a signal. In this study, this transform is used to identify and extract the acoustic components from multipath time series. The inversion is formulated as an optimization problem which maximizes the cost function defined as a normalized correlation between the measured and modeled signals in the wavelet transform coefficient vector. The experiments and procedures for deploying the light bulbs and the coherent broadband inversion method are described, and the estimated geoacoustic profile in the vicinity of the VLA site is presented.

Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements (현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.329-337
    • /
    • 2017
  • In USA and UK, the standards of both reverberation time and background noise level have been established for the appropriate aural environment in classrooms. In order to realize this, guidelines for architectural planning and interior finishing have been also suggested. However, in Korea, there has hardly been any guidelines for satisfying background noise criteria and investigation about sound insulation performance of current walls of classrooms. The present study investigates the structure of outer wall and walls between classrooms of two middle schools in order to analyze the sound insulation performance against both exterior and interior noises. Acoustic parameters including transmission loss, standardized sound level difference, and signal to noise ratio have been measured and analyzed for sound insulation performance of walls and flanking noises. As a result, concerning the walls in between classrooms, it was found that walls of dry construction have greater sound insulation performance rather than the walls of wet construction especially in mid and high frequency bands. Also, It was revealed that thermopane, insulated pair glass, of outer walls, has greater sound insulation performance than the double window consisted of two single pane glass. Regarding flanking noises, the standards were exceeded when all windows, or windows and doors front onto corridor were opened. It denotes that students could be disturbed with the sound transmission by the interior noises.

The Efficacy of Percutaneous Steroid Injection via Cricothyroid Membrane for Reinke's Edema (라인케씨 부종 환자에서 경윤상 갑상막 접근을 통한 성대 내 스테로이드 주입술의 효용)

  • Nam, Woojoo;Kim, Sun Woo;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.101-106
    • /
    • 2019
  • Background and Objectives Reinke's edema is a benign vocal fold disease caused by an edematous laryngeal superficial layer of lamina propria. The first line treatment is cessation of smoking and laryngeal microsurgery. The aim of the study is to evaluate the feasibility and efficacy of percutaneous steroid injection via cricothyroid membrane in patients with Reinke's edema. Materials and Method From Jan 2010 to July 2018, 33 Patients with Reinke's edema managed by vocal fold steroid injection via the cricothyroid membrane were included in this study. We compared medical records of laryngoscopy, stroboscopy and Multi-Dimensional Voice Program analysis at pre-treatment and post-treatment. Subjective voice improvement was evaluated using Voice Handicap Index-30 (VHI-30). Results 75.7% of the patients showed partial response and 6.06% showed complete response. 93.94% were present smokers and only 4 patients ceased smoking after the treatment. In acoustic analysis, the pre-treatment mean value of jitter, shimmer, and noise to harmonic ratio was 2.30±3.21, 9.34±10.37, 1.11±2.90 each. The post-treatment value was 2.20±1.89, 6.96±5.30, 0.20±0.09 respectively and none of the parameters were statistically significant. For subjective symptom improvement, 25 (75.8%) patients showed a better score on post-treatment VHI-30 compared to pre-treatment. Conclusion According to our study, steroid injection is a relatively safe and effective procedure for patients with Reinke's edema. A vocal fold steroid injection via the cricothyroid membrane can be an alternative treatment option for those who are not able to undergo conventional laryngeal microscopic surgery, however cessation of smoking is necessary for effective treatment.

Magnitudes of the Harmonic Components Emitted from Utrasonic Contrast Agents in Response to a Diagnostic Utrasound: Theoretical Consideration (진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기: 이론적 고찰)

  • Kang Gwan Suk;Yu Ji Chul;Paeng Dong Guk;Rhim Sung Min;Choi Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.78-86
    • /
    • 2005
  • This study considers the magnitude of the harmonic components radiated from the ultrasonic contrast agents (UCA) activated by a typical diagnostic ultrasound. The nonlinear dynamic response of UCA to a 2 MHz diagnostic ultrasound pulse was predicted using Gilmore Model. The elastic property of the shell membrane of the UCA was ignored in the numerical model. Simulation was carried out for the UCA varying from 1 - 9 $\mu$m in its initial radius and the driving diagnostic ultrasound whose mechanical index (MI) ranges from 0.125 to 8. The powers of the sub. ultra and second harmonics of the acoustic signal from the UCA activated were compared with that of the fundamental component. The results show that. if the UCA is bigger than its resonant size (2 $\mu$m in radius for the present case) the sub harmonic power was much bigger than the fundamental. In particular, the 2nd harmonic component currently used as an imaging parameter for the harmonic imaging, was predicted to be lower in power than both the sub and the ultra harmonic component. This study indicates that, for obtaining harmonic imaging with UCA, the sub or ultra harmonics could be taken as imaging parameters better than the 2nd harmonic component.