• Title/Summary/Keyword: Acoustic Resonance

Search Result 431, Processing Time 0.043 seconds

Study on Smart Cooling Technology by Acoustic Streaming Generated by Ultrasonic Vibration Using 3D PIV (3차원 PIV를 활용한 초음파 진동에 의해 발생된 음향 유동을 이용한 스마트 냉각법 연구)

  • Lee, Dong-Ryul;Loh, Byoung-Gook;Kwon, Ki-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1078-1088
    • /
    • 2010
  • In order to analyze the quantitative characteristics of acoustic streaming, experimental setup of 3-D stereoscopic PIV(particle imaging velocimetry) was designed and quantitative ultrasonic flow fields in the gap between the ultrasonic vibrator and heat source were measured. Utilizing acoustic streaming induced by ultrasonic vibration, surface temperature drop of cooling object was also measured. The study on smart cooling method by acoustic streaming induced by ultrasonic vibration was performed due to the empirical relations of flow pattern, average flow velocity, different gaps, and enhancement on cooling rates in the gap. Average velocity fields and maximum acoustic streaming velocity in the open gap between the stationary cylindrical heat source and ultrasonic vibrator were experimentally measured at no vibration, resonance, and non-resonance. It was clearly observed that the enhancement of cooling rates existed owing to the acoustic air flow in the gap at resonance and non-resonance induced by ultrasonic vibration. The ultrasonic wave propagating into air in the gap creates steady-state secondary eddy called acoustic streaming which enhances heat transfer from the heat source to encompassing air. The intensity of the acoustic streaming induced by ultrasonic vibration experimentally depended upon the gap between the heat source and ultrasonic vibrator. The ultrasonic vibration at resonance caused the increase of the acoustic streaming velocity and convective heat transfer augmentation when the flow fields by 3D stereoscopic PIV and temperature drop of the heat source were measured experimentally. The acoustic streaming velocity of air enhancement on cooling rates in the gap is maximal when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which is specifically 12 mm.

A new method for extracting resonance information in acoustic wave resonance scattering (음향파 공명 산란의 새로운 해석방법)

  • 이희남;박영진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.504-509
    • /
    • 1998
  • A new method is proposed for the isolation of resonances from scattered waves for acoustic wave resonance scattering problems. The resonance scattering function consisting purely of resonance information is defined. Acoustic wave scattering from a variety of submerged bodies is numerically analyzed. The classical resonance scattering theory (RST) and the new method compute identical magnitude of the resonance from each scattered partial wave, however, the phases are significantly different. The exact .pi.-radians phase shifts through the resonance and anti-resonance show that the proposed method properly extracts the vibrational resonance information of the scatterer. Due to the difference in the phase of each, partial wave, the new method and RST generate different total resonance spectra.

  • PDF

A Case Study on the Reduction of Noise and Vibration at the Backpass Heat Surface in the Power Plant Boiler (발전용 보일러 후부 전열면 소음진동 저감에 관한 연구)

  • Lee, Gyong-Soon;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.54-59
    • /
    • 2008
  • The resonance of boiler is caused by exciting force in the gas path and it generates the vibration by the harmony of boiler's dimensional factor. According to trending toward the boiler of increasing capacity and a bigger size, it has a problem of the vibration at back-pass heating surfaces. We can predict such vibrations as comparison between vortex frequency and gas column's natural frequency. We can't rely on the method for the past decades because of changing parameters, such as an allowable error, gas temperature, gas velocity, Strouhal number. We can reduce the vibration to use the seasoning effect and change the operating condition in coal fired boiler but it's not essential solution. When the vibration occurred in the model boiler, we must measures the acoustic pressure and frequency of places for considering the means. So far, we confirmed the problem from field measures and theoretical analysis about the acoustic vibration of boiler. We installed anti-acoustic baffle in a existing boiler to change the acoustic natural frequency at the cavity, which results in reducing the acoustic vibration. The first, we prove that the acoustic resonance is caused by harmonizing vortex shedding frequency of tube heat surface with acoustic natural frequency of cavity in the range of 650~750 MW loads. The second, the acoustic resonance at the back-pass heating surface has the third order of acoustic natural frequency at the second economizer. We install five anti-acoustic baffles at the second economizer to reducing the resonance. We confirm considerably reducing the acoustic vibration of boiler during the commercial boiler.

  • PDF

Experimental Study on Flame-Vortex Interactions in Turbulent Hydrogen Non-premixed Flames with Coaxial Air (동축공기 수소확산 화염에서의 화염과 와류의 상호작용 실험연구)

  • Kim, Mun-Ki;Oh, Jeong-Suk;Choi, Young-Il;Yoon, Young-Bin
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.86-94
    • /
    • 2006
  • This paper investigates the effects of acoustic forcing on NOx emissions and mixing process in the near field region of turbulent hydrogen nonpremixed flames. The resonance frequency was selected to force the coaxial air jet acoustically, because the resonance frequency is effective to amplify the forcing amplitude and reduce NOx emissions. When the resonance frequency is acoustically excited, a streamwise vortex is formed in the mixing layer between the coaxial air jet and coflowing air. As the vortex develops downstream, it entrains both ambient air and combustion products into the coaxial air jet to mix well. In addition, the strong vortex pulls the flame surface toward the coaxial air jet, causing intense chemical reaction. Acoustic excitation also causes velocity fluctuations of coaxial air jet as well as fuel jet but, the maximum value of centerline fuel velocity fluctuation occurs at the different phases of $\Phi$=$180^{\circ}$ for nonreacting case and $\Phi$=$0^{\circ}$ for reacting case. Since acoustic excitation enhances the mixing rate of fuel and air, the line of the stoichiometric mixture fraction becomes narrow. Finally, acoustic forcing at the resonance frequency reduces the normalized flame length by 15 % and EINOx by 25 %, compared to the flame without acoustic excitation.

  • PDF

Acoustic Resonance Reduction Technique in HID-lamps by the FM Driving Signal for the Inverter (인버터 구동신호의 주파수 변조에 의한 HID 램프의 음향 공명 감소 기법)

  • Park, Chong-Yun;Choe, Hyueon-Hui;Lim, Ki-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1981-1987
    • /
    • 2008
  • This paper proposed one of various acoustic resonance reduction technique for three kinds of ceramic lamps (CDM-150, HCI-150, CMH-150). To reduce the acoustic resonance in the HID lamps, the researched results showed that the frequency modulated signal with the triangle waveform is very effective in order to drive th LCC type half-bridge inverter for HID lamp. Experimental results proved that the acoustic resonance could be rejected, if the adequate switching frequency band is selected and the driving signal frequency is modulated with a triangle waveform.

Resonance Mode Anlaysis in a Single Can-type Combustor through 3D Thermo-acoustic Analysis based on Helmholtz Solver (헬름홀츠 솔버 기반의 3차원 열음향해석을 통한 발전용 단일 캔 연소기에서의 공진 모드 분석)

  • Junwoo Jung;Daesik Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2024
  • This study conducted a 3D thermo-acoustic analysis based on the helmholtz solver to analyze the major resonance modes causing combustion instability in a single-can combustor. The experimental investigations were carried out on a test rig designed by the Korea Institute of Machinery & Materials (KIMM) under various conditions of hydrogen co-firing and fuel staging. Through these experiments, two primary unstable frequencies were identified. To determine the resonance modes of these frequencies, a 3D thermo-acoustic analysis was conducted using temperature information from the test rig. The results confirmed that the unstable frequencies observed in the experiments were all longitudinal modes. Additionally, the mode shapes identified in the analysis facilitated a simplification of the exit geometry for the low-order network model, confirming that this did not significantly affect the fundamental resonance modes.

A Study on Electronic Ballast for 1[kW] Metal-Halide Lamp Developed by Eliminating Acoustic Resonance using Frequency Modulation Method (주파수 변조 기법을 이용하여 음향공명 현상을 제거한 1[kW] 메탈 핼라이드 램프용 전자식 안정기 개발)

  • Park, Chong-Yun;Lee, Bong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.10-18
    • /
    • 2008
  • This paper presents the design and imelementation of an electronic ballast with a passive PFC structure from which acoustic resonance of the metal halide lamp was removed by introducing the frequency modulation(FM) method. The proposed ballast consists of an EMI filter, passive PFC circuit full-bridge inverter, LC resonance type igniter and a circuit for removing acoustic resonance. The FM method solved two problems associated with single frequency driving: variation of the acoustic resonance range according to lamp aging and the acoustic resonance range discrepancy caused by different materials sealed inside the arc tube and their pressures for arc tubes of identical sizes from different manufacturers. Performance of the prototype developed for this study of the electronic ballast for 1[kW] metal halide lamp was verified by evaluating its optical conversion efficiency, input PF, input current THD and power conversion efficiency.

Resonance Condition of the Resonance Cavity and Air Gap in the Sacred Bell of the Great King Seongdeok (성덕대왕신종의 명동과 간극의 공명조건)

  • Kim, Seock-Hyun;Jeong, Won-Tae;Kang, Yun-June
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.223-230
    • /
    • 2011
  • Korean bell is hung with some air gap between the bell bottom and the ground. In addition, it has a peculiar acoustic element, so called resonance cavity below the bell. A proper design of the air gap and cavity size dramatically amplifies the bell sound by resonance effect. Bell interior cavity, air gap and resonance cavity consist of an acoustic cavity system. When the acoustic cavity frequency coincides with the natural frequency of the bell body, the frequency component is significantly amplified. On the Sacred Bell of the Great King Seongdeok, this study proposes a resonance condition of the cavity system considering air gap effect for the first time. With the exact dimension of the bell, boundary element analysis is performed using SYSNOISE. Finally, this study reveals how the temperature in season influences the resonance condition and proposes a concept of variable type resonance cavity. By using the variable type resonance cavity, the cavity size is controlled on site and exact resonance is available regardless of temperature difference in season.

Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W) (고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소)

  • 김기정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2001
  • MetalHalid lamps have good efficiency, good color rendition and good focusing capability. But the shortcoming of metalhalid lamps is blown as acoustic resonance phenomena in the arc tube. Such acoustic resonance produce annoying fluctuations in the intensity and distribution of the emitted light, they can raise the voltage to the point where the arc is extinguished and they can move the arc close enough to the wall to cause local overheating and tube cracking. The objective of this research is to reduce acoustic resonance in the arc tube of the Pulse Start MetaIHaide lamp(MH200[W]). To reduce the acoustic resonance phenomena the electronic ballast was designed for high frequency operation with the constant frequency sinusoidal wave of 89[kHz] in the 84.6[kHz]∼94.2[kHz] range. Experimental results show that the acoustic resonance phenomena are not in the arc tube of Pulse Start MetalHalide lamp (MH200[W]) .

  • PDF

Study on Acoustic Resonance of Air-conditioner Fan BLDC Motor (에어컨 홴 BLDC 전동기의 음향공진에 관한 연구)

  • Lee, Hong-Joo;Kwon, Joong-Hak;Lee, Chang-Min;Hwang, Gun-Yong;Hwang, Sang-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.863-869
    • /
    • 2009
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. This paper analyzes noise characteristics of a brushless DC motor for air-conditioner fan, and proves that the test motor noise originates from acoustic modes of airspace in the motor. The motor noise sensitivity analysis by design of experiments reveals that the noise characteristics are closely related to switching frequency and frame thickness.