• Title/Summary/Keyword: Acoustic Fluid

Search Result 303, Processing Time 0.022 seconds

An Experimental Study on Vehicle Exhaust System Components in Spark-Ignition Engines (SI엔진 배기시스템 성분들에 관한 실험적 연구)

  • Song, Chang-Hoon;Lee, Hae-Chul;Seog, Bong-Hyun;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.757-763
    • /
    • 2000
  • In vehicle exhaust systems the sound attenuation and the reduction of flow losses are often two competing demands. The present study considers a fully vehicle exhaust system and investigates experimentally both the sound attenuation and the flow performance of production configurations including the catalyst, the resonator, and the muffler. Dynamometer experiments have been This study is on the development of a new muffler composed of a valve system using an elasticity of spring. The valve system conducted with the daewoo 1500cc Lanos engine with speeds ranging from 1000 to 5000 rpm. Measurements include the flow rates, the temperatures and the absolute dynamic pressures of the hot exhaust gases at point locations. The present study describes the experimental aspects of an ongoing effort to validate and use the nonlinear fluid dynamic models in the time-domain for the prediction of the acoustic and power performance of firing internal combustion engines with full production exhaust systems.

  • PDF

An Experimental Study of enhancing heat transfer by Ultrasonic Vibration (초음파 가진에 따른 열전달 향상에 관한 연구)

  • Youn, Joung-Hwan;Oh, Yool-Kwon;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.235-240
    • /
    • 2001
  • This study presents experimental work on phase change heat transfer, in order to increase heat transfer rate, ultrasonic vibrations were introduced. Solid-liquid phase change occurs in a number of situations of practical interest. This study reveal that ultrasonic vibrations accompany the effects like agitation, acoustic streaming, cavitation, and oscillating fluid motion. Such effects are a prime mechanism in the overall melting process when ultrasonic vibrations are applied. Some common examples include the melting of edible oil, metallurgical process such as casting and welding, and materials science applications such as crystal growth. Therefore, this study presented the effective way to enhance phase change heat transfer.

  • PDF

Smart Suction Muffler for a Reciprocating Compressor (왕복동 압축기에서의 고효율, 저소음 흡입머플러 개발)

  • Ju, Jae-Man;Choe, Jin-Gyu;O, Sang-Gyeong;Park, Seong-U
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1429-1436
    • /
    • 2000
  • Suction muffler is one of the important component of a compressor for low noise level and high efficiency. The suction muffler which has the complicated flow path gives the higher transmission loss of sound, but lower efficiency of compressor results from the superheating effect and flow loss in suction flow path. It is shown that the computational analysis of fluid dynamics are very popular methods for designing of high performance and low noise suction muffler. To reduce the thermodynamic and flow loss in suction process, the flow path of suction muffler was estimated by FVM(Finite Volume Method) and verified by experiments. And to enlarge the transmission loss of sound, the acoustic properties inside the suction muffler was analyzed by FEM(Finite Element Method) and experiments. The smart muffler which gives a good efficiency and low noise character was developed by using those methods, and the effect was evaluated in compressor by experiment.

  • PDF

Hydraulic Efficiency measurement of small turbine and example of it's analysis (소수력수차의 효율측정과 분석사례)

  • Kim, Eung-Tae;Jung, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.748-756
    • /
    • 2005
  • The Purpose of this writing is a presentation of small turbine efficiency measuring method, applicable new technology, and several analysis result for real turbine. Measurement methods of hydraulic efficiency written in here are extracted from small turbine applicable international code(IEC, ASME). It includes brief synopsis of 'Current meter method' and 4 other methods and ASFM as a new small turbine applicable technology. And several analysis of test result are for recently performed domestic small turbine result in korea. Through this presentation of extracted code, I hope that it make other small turbine concerner be familiar to perform an efficiency test. for small turbine. And, some analysis of that, make other to feel the importance of efficiency test.

  • PDF

Acoustic Analysis of Plenum Fan using Kirchhoff-BEM (Kirchhoff-BEM 을 이용한 Plenum Fan 소음해석)

  • Song, W.-S.;Jang, G. J.;Lee, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.89-93
    • /
    • 2004
  • To numerically construct the sound fields by a plenum fan mostly found in Air-Handling Unit (AHU), the Kirchhoff-BEM approach was applied to the near-field data of a turbo fan. The scattering effects were found to be significant by the plenum box structure for high-frequency components of source. The directivity petterns and sound pressure levels were also dependent upon the helmholts number which must be considered of the design stage for sound reduction program.

  • PDF

Development of a Low Noise and High Efficiency Rotary Compressor by a New Muffler (신규 저소음 및 고효율 머플러 적용 회전식 압축기 개발)

  • Jarng, In-Sun;Kim, Bong-Jun;Youn, Young;Sung, Choon-Mo;Lee, Seung-Gap
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.533-539
    • /
    • 2004
  • The rotary compressor is widely used for the air conditioner because it is efficient and compact. In recent, the need for silent and efficient compressors is much stronger than the past. The new type muffler was invented to reduce noise level and to improve efficiency. The new type muffler that has two side discharge holes and dome shape represents much lower overall noise level, especially noise levels around 1kHz than the old type one that has one center discharge hole In acoustic spectra. Also it has higher air conditioner efficiency by lower oil discharging amount of a compressor than old type one that has rectangular shape and two side discharge holes. The noise reduction and efficiency improvement effects of the new type muffler were verified by tests for rotary compressors and air conditioners.

  • PDF

Acoustic Analysis of Unevenly Pitched Fan of Automobile Cooling Pack System (자동차 Cooling Fan용 비등각 축류홴 소음해석)

  • Song, W.-S.;Lee, J.-S.;Kim, J.-Y.;Lee, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.567-571
    • /
    • 2004
  • The 2-dimensional unsteady flows on and around the cambered airfoils were computed by applying LES with the deductive dynamic SGS model. The unsteady flow field were used as inputs to compute the far-field sounds and directivity patterns from rotating blades by a hybrid approach that exploits Farassat's formula. The BEM (Boundary Element Method) was applied to predict the frequency characteristics from the rotating blades for the cases of even- and uneven-pitched fans. The BEM results suggested that the unevenly pitched fan have less pronounced discrete peaks at BEF frequencies, which was confirmed by the experiment.

  • PDF

Detection of Noise Sources in a Cavitation Tunnel by using Beam-Forming Method (빔형성 기법을 이용한 공동수조 내부의 소음원 탐지)

  • 이정학;서종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.749-754
    • /
    • 2003
  • In this paper, we introduce the measurement of the underwater noise with 32channel hydrophone array of Samsung CAvitation Tunnel (SCAT) and the detection technique of noise sources by using the beam-forming method. Measurement and way signal Processing under fluid flow are essential works for the underwater acoustics, especially for the detection of noise sources. As the acoustic impedance of the water is relatively high and the tunnel is an enclosed system, we have to consider the interaction between tunnel and water together with the reflection of noise in the beam-forming technique. Also, for a hydrophone array system that is fixed on one side of tunnel wall as done in SCAT is liable to suffer from some limitations in the detection of the noise sources with the array, we discuss these limitations particularly on the frequency range and spacing of noise sources.

  • PDF

Mean Flow Velocity Measurement Using the Sound Field Reconstruction (음장 재구성에 의한 관내 평균유속 측정)

  • Kim, Kun-Soon;Cheung, Wan-Sup;Kwon, Hyu-Sang;Park, Kyung-Am;Paik, Jong-Seung;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.924-929
    • /
    • 2000
  • This paper addresses a new technique of measuring the mean flow velocity over the cross sectional area of the pipe using sound field reconstruction. When fluid flows in the pipe and two plane waves propagate oppositely through the medium, the flow velocity causes the change of wave number of the plane waves. The wave number of the positive going plane wave decreases and that of negative going one increases in comparison to static medium in the pipe. Theoretical backgrounds of this method are introduced in detail and the measurement of mean flow velocity using the sound field reconstruction is not affected by velocity profile upstream of microphones.

Desktop PC CPU Cooling System Design and Analysis

  • Choi, Jee-Hoon;Yoo, Jung-Hyun;Seo, Min-Whan;Kang, Shin-Jae;Kim, Chul-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.601-604
    • /
    • 2008
  • Desktop PC CPUs have been significantly required to be the necessity of thermal management while they have satisfied the extensive data and graphic processing requirements. So the cooling systems assembled with heat pipes embedded in a metal cooling plate, and fins are widely used in the desktop PC markets. Due to a number of demands such as the confined space of desktop PCs, higher heat density of CPUs, and acoustic noise, however, there is the main drive to improve continuously cooling systems. This paper presents the flow and thermal behavior of the cooling system by using the computational fluid dynamics(CFD) code.

  • PDF