• Title/Summary/Keyword: Acetic Acid Removal

Search Result 81, Processing Time 0.021 seconds

Effect of Viscous Materials Removal from Sea Tangle Extracts on Volatile Flavor Constituents (점성물질 제거가 다시마 추출액의 휘발성 향미성분에 미치는 영향)

  • Lee, Jung-Kun;Yoon, Suk-Kwon;Kim, Woo-Jung;Choi, Hee-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.384-388
    • /
    • 1996
  • Volatile flavor compounds of a sea tangle powder and two kinds of extract were analyzed by GC/MS. Extract I was prepared by boiling for 2 hours and centrifugation, while extract II by a sequential procedure of enzymatic hydrolysis, boiling in 1.5% NaCl solution. centrifugation and ultrafiltration to remove viscous materials. Fifty six volatile compounds from the dried sea tangle powder and the extracts were identified. The GC profiles of the extract II were different from those of the dried powder and the extract 1, indicating most volatile compounds were lost during removing viscous materials. Particularly those compounds in the initial and later parts of the GC profiles were significantly decreased and some of the compounds such as fatty acids. 3,5-nonadien-2-ol and 1-penton-3-ol were not detected.

  • PDF

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Evaluation of Biological and Physico-chemical Detoxification Methods for the Removal of Inhibitors in Lignocellulose Hydrolysate (목질계 바이오매스 가수분해물 중 발효저해 물질에 대한 생물학적 및 물리화학적 무독화 방법의 평가)

  • Cho, Dae-Haeng;Kim, Yong-Hwan
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.415-419
    • /
    • 2009
  • In this study, the detoxification methods were evaluated for the removal of fermentation inhibitors from synthetic solution containing the composition similar to the lignocellulosic hydrolysate. The enzyme peroxidase and laccase were used as a biological treatment method. The physico-chemical methods such as adsorption and ion exchange were applied by using activated charcoal and ion exchange resins. The enzyme peroxidase showed a excellent removal of phenolic compounds. The 5-HMF and furfural were completely removed by activated charcoal. The anion exchange resin showed a good result for detoxification of acetic acid. The activated charcoal and ion exchange resins lead to a loss of sugars more or less. The choice of detoxification method must be made after considering the composition and inhibitors in hydrolysates.

A study on the washing remediation of tailing waste and contaminated surrounding soil of a bandoned metal mines (폐금속광산 광미 및 주변 오염토양 세정에 관한 연구)

  • 이동호;박옥현
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.87-101
    • /
    • 1999
  • This study has been carried out to examine the feasibility of washing technique for reducing the heavy metal contamination level of tailing wastes and agricultural soil surrounding abandoned metal mines. Some organic acids with low molecular weight were used as washing solution. Initial contamination levels of copper and lead for some soil samples were found to exceed the standard levels of countermeasure and concern, and those of cadmium to approach the standard level of countermeasure. Experimental results using sequential extraction method revealed that more than half of copper and lead existing in tailing wastes are adsorbed forms available for plants. There are some proportional relationships between metal concentrations determined by using 0.1N HCI solution and those determined by sequential extractions. Citric acid was turned out to be superior to oxalic acid and acetic acid with low molecular weight in washing above three metals. When citric acid is used for washing heavy metals from soil, it is desirable to operate at pH less than 5.5 for better washing effect. Metal removal effect by citric acid solution has been proved to depend upon solution concentration and the mass ratio of solution to soil. Addition of SDS(Sodium Dodecyl Sulfate) to citric acid improved the washing effect of cadmium among three metal most significantly. while copper removal did not change. Washing technique using citric acid for removal of heavy metals from agricultural soil or tailing wastes is recognized to be an effective remediation method.

  • PDF

Preparation of Chitosan/Poly-${\gamma}$-glutamic Acid Nanoparticles and Their Application to Removal of Heavy Metals (키토산/폴리감마글루탐산 나노입자의 제조 및 중금속 제거에의 응용)

  • Sung, Ik-Kyoung;Song, Jae Yong;Kim, Beom Soo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.475-479
    • /
    • 2011
  • Chitosan is a natural polymer that has many physicochemical(polycationic, reactive OH and $NH_2$ groups) and biological(bioactive, biocompatible, and biodegradable) properties. In this study, chitosan nanoparticles were prepared using poly-${\gamma}$-glutamic acid(${\gamma}$-PGA) as gelling agent. Nanoparticles were formed by ionic interaction between carboxylic groups in ${\gamma}$-PGA and amino groups in chitosan. Chitosan(0.1~1 g) was dissolved in 100 ml of acetic acid (1% v/v) at room temperature and stirred overnight to ensure a complete solubility. An amount of 0.1 g of ${\gamma}$-PGA was dissolved in 90 ml of distilled water at room temperature. Chitosan solution was dropped through needle into beaker containing ${\gamma}$-PGA solution under gentle stirring at room temperature. The average particle sizes were in the range of 80~300 nm. The prepared chitosan/${\gamma}$-PGA nanoparticles were used to examine their removal of several heavy metal ions($Cd^{2+}$, $Pb^{2+}$, $Zn^{2+}$, $Cu^{2+}$, and $Ni^{2+}$) as adsorbents in aqueous solution. The heavy metal removal capacity of the nanoparticles was in the order of $Cu^{2+}$ > $Pb^{2+}$ > $Cd^{2+}$ > $Ni^{2+}$ > $Zn^{2+}$.

Characteristics of H2 Production from Swine wastewater (양돈폐수로부터의 수소 생성 특성)

  • Chang, Young-Bok;Jeong, Tae-Young;Cha, Gi-Cheol;Chung, Hyung-Keun;Kim, Seong-Hun;Kim, Dong-Jin;Yoo, Ik-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2004
  • The characteristics of $H_2$ production from livestock wastewater were investigated through an anaerobic acid forming process using Clostridium beijerinckii and the photosynthetic process using Rhodobacter sphaeroides. The submerged separation membrane was installed in the acid forming reactor, The photosynthetic process is composed of two reactors(photosynthetic reactor 1 and photosynthetic reactor 2) which is connected continually. The removal rate of COD and the production of volatile fatty acid(VFA) in the acid forming process were approximately 50% and 1000mg/L, respectively. The 70% of COD in the effluent of acid forming process was removed through the photosynthetic process. The production of $H_2$ in the photosynthetic reactor 1 and 2 was 50 and $25mLH_2/gVFA_{COD}$, respectively. The values of Y in acid forming reactor, photosynthetic reactor 1 and 2 was 0.2263, 0.0601 and 0.0393, respectively. The acetic acid and butyric acid produced in acid forming process were converted to $H_2$ by photosynthetic bacteria.

Characterization of Heavy Metal-enriched Particles from Contaminated Soils in a Military Shooting Range (군사격장 오염토양 내 고농도 중금속함유 입자의 기초특성연구)

  • Kim, Jeeeun;Kim, Jeongjin;Bae, Bumhan;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.25-31
    • /
    • 2013
  • Civil and military firing ranges are usually contaminated with heavy metals such as lead and copper and remediation is required. Acid washing and extraction are common remediation methods. Lead contaminated firing range soil samples were collected and a preliminary study was conducted to evaluate the characteristics of the contamination and the contribution of high specific gravity particles. Ethylenediamine tetra acetic acid(EDTA) extraction was applied for the removal of heavy metal but the extraction was not feasible for the firing range soil. Even after the repeated EDTA extraction, the contamination were still over the Korean environmental standard indicating that soil particles highly contaminated with heavy metal which release the heavy metal ion even after the repeated extraction. Some colored and higher specific gravity particles were separated from the soil samples and analyzed. The colored particles have specific gravity of 2.5-6.6. The saturation ratio of Pb and EDTA was 4.9-32%. After removal of these colored particles, the sandy soil showed moderate contamination which can be treated with soil washing. This was proved with the five-level sequential extraction and TCLP tests.

Isolation and Identification of a Lactic Acid Bacterial Strain KJ-108 and Its Capability for Deodorizing Malodorous Gases Under Anaerobic Culture Conditions

  • KIM, JEONG-DONG;JUNG-HOON YOON;YONG-HA PARK;DAE-WEON LEE;KYOU-SEUNG LEE;CHANG-HYUN CHOI;WON-YEOP PARK;KOOK-HEE KANG
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.2
    • /
    • pp.207-216
    • /
    • 2003
  • A number of different sources, such as composts, leachates, and pig feces samples, were collected from different pig farms in Korea, and several microorganisms were screened for their ability to deodorize the malodorous gases. Consequently, a novel malodorous gases-deodorizing bacterial strain, KJ-108. was isolated, because it was highly abundant in nitrate-supplemented minimal medium ($MM-NO_3^-$) under anaerobic culture conditions. Airtight crimp-sealed serum bottles containing $MM-NO_3^-$ , medium were inoculated with KJ-108. Nitrate concentration was decreased rapidly after 20 h of incubation, and incubation was carried out until nitrite production reached almost zero. Taxonomic identification, including 16S rDNA base sequencing and phylogenetic analysis, indicated that the isolate had $100\%$ homology in its 165 rDNA base sequence with Lactobacillus pentosus. Among the volatile fatty acids, acetic acid contained in large amounts in fresh piggery slurry was decreased by about $40\%$ after 50 h incubation with strain KJ-108. n-Butyric acid, n-valeric acid, and isovaleric acid were gradually decreased, and isobutyric acid and capronic acid were dramatically eliminated at theinitial period with the treatment. Moreover, NH, removal efficiency reached a maximum of $98.5\%$ after 50 h of incubation, but the concentration of $H_2S$ was not changed.

Studies on the Wastewater Treatment and Wastewater Characteristics from Acetaldehyde (아세트 알데히드 공장 폐수의 특성 및 화학적 처리)

  • 강선태;서승교;김정호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.17-21
    • /
    • 1991
  • As a research for treatment of wastewater from acetaldehyde plant by biological method, we investigated general characteristics of the wastewater as well as the effect of coagulants. COD and BOD of the wastewater were 5260 ppm and 6452 ppm, respectively, and pH was 1.86. COD and BOD of the wastewater were 214, 000ppm and 15190ppm, respectively, and pH was 2.4. And the main organic componnt in wastewater were acetic acid were contained 6.76 % and 14.5 %, respectively. FeSO$_{4}$ as the coagulated was the most effective. The COD removal rate was reached to maximum state by supplementing 1200 ppm FeSO$_{4}$ and pH 9.5.

  • PDF

An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material (은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구)

  • Nam, Sang-Yeob;Kang, Byung-Ha;Song, Ji-Hyeon;Han, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF