• Title/Summary/Keyword: Accuracy of chest compression

Search Result 42, Processing Time 0.027 seconds

Accuracy analysis of artificial respiration and chest compressions when performing CPR using a mannequin by college students (대학생의 마네킹을 이용한 심폐소생술 시행 시 인공호흡과 흉부압박의 정확도 분석)

  • Jeon Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.167-173
    • /
    • 2023
  • The purpose of this study was to analyze the accuracy of artificial respiration and chest compressions using CPR mannequins for university students. First, in the number of chest compressions, subjects A, F, H, I, and J showed similar numbers from 60 to 63, respectively, which were much lower than the standard. Subjects B, D, E, and G showed 90 to 91 times, maintaining the normal range. However, C was rather high with 119 times. Second, the depth of chest compression was 58.60mm, and most of them were deeply compressed. Subject C was close to normal at 51mm, and subjects A to J were significantly higher at 55mm to 62mm. The reason seems to be the result of an unstable psychological state with no experience of chest compressions and a lack of self-confidence. Third, in terms of accuracy, subject E showed the lowest accuracy at 12%, and A~J showed 33%~80%. Experiment subject B showed 95% accuracy, which seems to be the result of D accurately recognizing the chest compression point through theoretical training during military service.

Comparison of Educational Effects on Hands-only Cardiopulmonary Resuscitation (CPR) with Basic Cardiopulmonary Resuscitation (CPR) by Elementary School Students (초등학생 가슴압박소생술과 기본심폐소생술의 교육효과 비교)

  • Ahn, Myung Ja;Kim, Young Im
    • Journal of the Korean Society of School Health
    • /
    • v.27 no.3
    • /
    • pp.130-139
    • /
    • 2014
  • Purpose: The object of this study was to compare the educational effect about self-efficacy and the quality of chest compressions of Hands-only CPR and Basic CPR. Methods: It's a nonequivalent control group pre-post repeated quasi-experiment study conducted with entire fifth grade students belong to one school in H city. The study participants are 68 persons, and data were collected from December 2, 2013 to February 7, 2014. Self-efficacy was measured by 10 items, and the quality of chest compressions was measured by 5 variables which are average compression depth(mm), average rate (n/min), average count per minutes (n), abnormal placement (n), compression accuracy (%). Results: Self-efficacy of the experimental group and control group showed no significant difference but showed significant difference over time and was the highest at posttest 1 (immediately after education), the lowest at pretest (before education), middle at posttest 2 (8weeks after education) (p<.001). Experimental group was significantly higher than control group in average rate per minute. At posttest 1, experimental group was $130.0{\pm}9.38$ times, control group was $95.1{\pm}11.82$ times. At posttest2, experimental group was $124.0{\pm}14.89$ times, control group was $90.8{\pm}14.89$ times.(p<.001). Average rate (n/min) was significantly declined at control group in the quality of chest compressions over time (t=-2.400, p=.022). Average count per minute and compression accuracy were declined significantly so it were not maintained to posttest2. Conclusion: We need continuous CPR education because self-efficacy of CPR getting lower significantly over time. Hands-only CPR can't be seen as a way to increase the CPR ability of elementary school students having difficulty to perform artificial breathing. And, because the effect of education is not maintained 8wks after training, the technique centered repeated training is needed and a method which can increase compression accuracy is also needed.

Analysis of Adult Cardiopulmonary Resuscitation Skill Performed by Emergency Medical Technicians in Fire Department (소방 2급응급구조사의 성인 심폐소생술에 대한 숙련도 분석)

  • 최용철;이창섭;왕순주
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • Purpose: The purpose of this study is to predict a reasonable direction to design a pertinent educational program in the future by evaluating an adult CPR(Cardiopulmonary Resuscitation) skill performed by EMTs engaged in fire services organization and comparing the CPR success rate of factors as like a duty place and licensed year. Methods: We studied CPR skill by the use of a CPR manikin(Skillmeter Resusci Annie, Laerdal company). The study population consisted of 320 EMTs. Every EMT performed four cycle after investigating the manikin for 2 minutes. We regarded chest compression with 100 times in a minute as the 100% success rate. We analysed the skill of chest compression, ventilation and chest compression times success rate by the records printed in the CPR paper. Results: The average success rate of chest compression was 59.42$\pm$29.26% and ventilation 49.22$\pm$29.65%. The success rate of manual CPR was different between chest compression and ventilation. Also the success rate of chest compression times was high relatively as a 87.32$\pm$9.14%(p=0.000). For the CPR skill, ventilation was lowest as 49.22%. The factors such as duty place and licensed year did not influence the CPR success rate (p>0.001). Conclusion: We could have conclusion that CPR training should be shared more time in ventilation than in chest compression. Also we could reach to a conclusion that it is important to increase the times of CPR training for improving the accuracy of CPR and that the continuing education of CPR training frequency might be more than four times in a year.

Comparison of New Infant Chest Compression Methods: Simulation Study on Randomization Using Manikin

  • Yun, Seong-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.4
    • /
    • pp.153-159
    • /
    • 2019
  • In this paper, we propose a the effects of new chest compressions in the implementation of chest compressions during infant cardiopulmonary resuscitation, and to provide basic data for high-quality CPR. On March 12, 2019, the research target used the SPSS 22.0 Version as an experimental study using randomized cross-design of 30 emergency medical services students who completed BLS Health Care-provider. The study also showed significant differences in chest depth and average rate of pressure($34.61{\pm}1.29$, $39.40{\pm}1.08$, <0.001, $105.46{\pm}4.23$, $107{\pm}3.84$, <0.001) depending on chest compressions. There was also a significant difference in the convenience and degree of pain of chest compressions(<0.001). In addition, new chest compressions appeared close to vertical and showed statistically significant differences(p<.001). Based on the results of this study, we can see that the accuracy of the new chest compressions during infant cardiopulmonary resuscitation is increased, and the depth of chest compressions is improved, improving the quality index of chest compressions. However, it will be necessary to further study the use of the new chest compressions to identify the potential for clinical use.

Effectiveness of chest compression by bystander on the home bed mattress

  • Hee-Jeong Ahn;Uk-Jin Choi;Gyu-Sik Shim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.173-180
    • /
    • 2024
  • The purpose of this study was to determine the accuracy of chest compression according to the patient body weight and the rescuer's weight when performing chest compression on a cardiac arrest patient that occurred on a home bed. From January 07 to January 19, 2023, 36 paramedic students from N and S universities who completed the KBLS provider curriculum of the Korea Cardiopulmonary Resuscitation Association were measured at the subject's knee position, the depth of the mattress being pressed by the weight of the manikin, and the depth of the mattress being pressed by the weight of the manikin were measured during continuous chest compression for 2 minutes. As a result of the study, if a child's cardiac arrest is found at home, the patient is moved to the floor to proceed with chest compression, and the first witness to find an adult cardiac arrest is recommended to proceed on the bed rather than force the patient under the bed to proceed with chest compression.

A Comparison of Accuracy in Artificial Respiration and Chest Compression Depending on Position, Gender, and Weight of a Victim Given Cardiopulmonary Resuscitation (심폐소생술 시행 시 피구조자의 위치, 성별, 체중에 따른 가슴압박과 인공호흡 정확도 비교)

  • Baek, Hong-Seok;Park, Sang-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.280-290
    • /
    • 2011
  • The purpose of this study was to increase accuracy in performing cardiopulmonary resuscitation through comparing accuracy between chest compression and artificial respiration depending on position, gender, and weight of a victim given conducting cardiopulmonary resuscitation. This study randomly sampled 72 college students in G Province (36 in the experimental group and 36 in the control group) to conduct a research from November 5 to 19, 2009. The collected data were analyzed by using an SPSS WIN 12.0 Version program. Since the results showed that most regions got more effective artificial respiration and chest compression on the right side than on the left side, it is necessary to apply cardiopulmonary resuscitation on the right side in terms of how to implement and instruct cardiopulmonary resuscitation in the future. However, it seems that continuous researches are necessary to see if cardiopulmonary resuscitation is more effective on the right side in terms of the survival rate in an actual emergency.

Physiologic changes on the rescuer and efficiency of CPR in the increased chest compression (흉부압박의 횟수증가가 구조자에게 미치는 생리학적 변화와 심폐소생술 정확도에 미치는 영향)

  • Choi, Uk-Jin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.43-53
    • /
    • 2008
  • Purpose : This study was designed to examine physiological changes in the body of rescuers conduct CPR according to the 2005 new guideline from American Heart Association. The ratio of artificial respiration has changed from 15 : 2 into 30 : 2 in 2005. The researcher tried to know the correlation between the physiological changes and the accuracy of CPR. Method : The examinees of this study were 26 students (Dept. of Emergency Medical Service). After the training, participants conducted 10 minute CPR and soon after the CPR, their vital signs were checked, and lactic acid and concentration of ammonia were analysed from their blood samples. Questionnaires to ask their subjective fatigue level were filled out after blood samples and 10 minute - CPR was performed. Results : 1) After the CPR, concentrations of ammonia were $149.71{\mu}{\ell}/d{\ell}$ and $162.17{\mu}{\ell}/d{\ell}$ in 15 : 2 and 30 : 2, respectively. The number was higher in 30 : 2 but it wan not statistically meaningful (p = .493). Log value of lactic acid was a little higher in 30 : 2 with 42 log($mmol/{\ell}$) and 54 log($mmol/{\ell}$) in 15 : 2 and 30 : 2, respectively but it was not statistically meaningful (p = .113). 2) Blood pressure in 15 : 2 and 30 : 2 were 118.50 mmHg and 125.08 mmHg while pulse in two different cases were 96.14 and 97.25, showing no statistically significant differences (blood pressure : p = .155, pulse : p = .841). 3) Subjective fatigue was a bit high in 30 : 2 with 5.93 and 6.92 points in 15 : 2 and 30 : 2 respectively but it was not statistically meaningful (p = .142). 4) In the 10 minute CPR, respiration accuracy was 96.21% in 15 : 2 and 94.79% in 30 : 2. There was no statistical significances between the two(p = .225). In the meanwhile, chest compression accuracy was 92.57% in 15 : 2 and 91.83% in 30 : 2. From the beginning to the end of chest compression, there showed no difference(p = .425). the type of CPR did not influence upon the accuracy of chest compression(p = .756). Conclusion : In the CPR conducted by skilled rescuers for 10 minutes, there were no statistically meaningful differences between 15 : 2 and 30 : 2 in the concentration of fatigue element in a blood, subjective fatigue, vital signs and accuracy of CPR. Therefore, 30 : 2 CPR recommended by American Heart Association need to be recommended and performed in scene size up.

  • PDF

A comparison of the quality of manual and mechanical chest compressions in a moving rescue boat (이동 중인 구조보트 내에서 수기가슴압박과 기계가슴압박의 질 비교)

  • Kim, Hwang-Lim;Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.1
    • /
    • pp.77-84
    • /
    • 2020
  • Purpose: This study was conducted to determine effective chest compression methods that could be used when performing cardiopulmonary resuscitation in rocking boats. Methods: Tests were conducted for four minutes using manual and mechanical chest compressions on two mannequins, placed in boats, and moving at a speed of 35km/hours on calm sea surfaces with wave heights of 0.5m and wind speeds of 2-3m/s (testing for two minutes, followed by rest, then a second round of testing for two minutes). To compare the quality of the chest compressions, data were analyzed using mannequins (Resusci Anne Q-CPR, Laerdal, Norway) and then statistically processed. Results: When chest compressions were administered in the moving rescue boat, an accuracy analysis showed that the pressure speed of the hand and mechanical techniques were normal, h owever, the pressure depth accuracies were 49.04% for manual techniques and 0% for mechanical techniques. The relaxation accuracies during compressions were 2.07% for manual techniques and 95.4% for mechanical techniques. Conclusion: When administering chest compressions in rocking rescue boats, mechanical rather than manual techniques should be preferentially considered.

Development of the Basic Life Support App Including Chest Compression Feedback (흉부압박 피드백 기능이 포함된 기본소생술 앱 개발)

  • Song, Yeongtak;Kim, Minwoo;Kim, Jinsung;Oh, Jaehoon;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.219-226
    • /
    • 2014
  • This study is to develop a basic life support (BLS) app using the android based smartphone and to evaluate the function of the app. Suggested app contains chest compression feedback function, the map of automated external defibrillator (AED), direct emergency call and the basic knowledge of BLS. Using the accelerometer of the smartphone, we implemented a real-time algorithm that estimates the chest compression depth and rate for high quality cardiopulmonary resuscitation (CPR). The accuracy of algorithm was evaluated by manikin experiment. We made contents which were easy to learn the BLS for the layperson and implemented a function that provides the AED location information based on the user's current location. From the manikin experiment, the chest compression depth and rate were no significant differences between the manikin data and the app's feedback data (p > 0.05). Developed BLS app was uploaded on Google Play Store and it was free to download. We expected that this app is useful to learn the BLS for the layperson.

A Chest Compression CPR Study Performed on a Main Stretcher : Comparative study between C-step and Over the Belly

  • Gyu-Sik Shim;Song-Yi Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.123-129
    • /
    • 2024
  • CPR is very important to paramedics, but the chest compression performed while on the move main stretcher is less accurate. The purpose of this study is to find out the difference between performing chest compression on the side of the main stretcher using C-step and on the patient's over the belly in order to increase the effect of CPR on the main object while on the move. As a result of the study, the appropriate depth (t=4.132, p=.000) and speed (t=7.177, p=.000) were shown in the group to which the C-step was applied, and the accuracy was higher (t=6.774, p=.000). In addition, it was found that there were few location defects (t=-5.197, p=.000) and too shallow errors (t=-2.948, p=.008) in the group to which the C-step was applied. In conclusion, mounting a C-step on the main stretcher seems to help improve the quality of chest compression, and it is thought that this will increase the efficiency of chest compression.