• 제목/요약/키워드: Accuracy and Agreement of Diagnosis

검색결과 67건 처리시간 0.023초

Ovarian Masses: Is Multi-detector Computed Tomography a Reliable Imaging Modality?

  • Khattak, Yasir Jamil;Hafeez, Saima;Alam, Tariq;Beg, Madiha;Awais, Mohammad;Masroor, Imrana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2627-2630
    • /
    • 2013
  • Background: Ovarian cancer continues to pose a major challenge to physicians and radiologists. It is the third most common gynecologic malignancy and estimated to be fifth leading cancer cause of death in women, constituting 23% of all gynecological malignancies. Multi-detector computed tomography (MDCT) appears to offer an excellent modality in diagnosing ovarian cancer based on combination of its availability, meticulous technique, efficacy and familiarity of radiologists and physicians. The aim of this study was to compute sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of 64-slice MDCT in classifying ovarian masses; 95% confidence intervals were reported. Materials and Methods: We prospectively designed a cross-sectional analytical study to collect data from July 2010 to August 2011 from a tertiary care hospital in Karachi, Pakistan. A sample of 105 women aged between 15-80 years referred for 64-MDCT of abdomen and pelvis with clinical suspicion of malignant ovarian cancer, irrespective of stage of disease, were enrolled by non-probability purposive sampling. All patients who were already known cases of histologically proven ovarian carcinoma and having some contraindication to radiation or iodinated contrast media were excluded. Results: Our prospective study reports sensitivity, specificity; positive and negative predictive values with 95%CI and accuracy were computed. Kappa was calculated to report agreement among the two radiologists. For reader A, MDCT was found to have 92% (0.83, 0.97) sensitivity and 86.7% (0.68, 0.96) specificity, while PPV and NPV were 94.5% (0.86, 0.98) and 86.7% (0.63, 0.92), respectively. Accuracy reported by reader A was 90.5%. For reader B, sensitivity, specificity, PPV and NPV were 94.6% (0.86, 0.98) 90% (0.72, 0.97) 96% (0.88, 0.99) and 87.1% (0.69, 0.95) respectively. Accuracy computed by reader B was 93.3%. Excellent agreement was found between the two radiologists with a significant kappa value of 0.887. Conclusion: Based on our study results, we conclude MDCT is a reliable imaging modality in diagnosis of ovarian masses accurately with insignificant interobserver variability.

Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

  • Mohammadpour, Mahdis;Bakhshalian, Neema;Shahab, Shahriar;Sadeghi, Shaya;Ataee, Mona;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.89-94
    • /
    • 2014
  • Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners

  • Camardella, Leonardo T.;Ongkosuwito, Edwin M.;Penning, E. Willemijn;Kuijpers-Jagtman, Anne Marie;Vilella, Oswaldo V.;Breuning, K. Hero
    • 대한치과교정학회지
    • /
    • 제50권1호
    • /
    • pp.13-25
    • /
    • 2020
  • Objective: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). Methods: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. Results: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. Conclusions: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably.

Diagnostic Image Feature and Performance of CT and Gadoxetic Acid Disodium-Enhanced MRI in Distinction of Combined Hepatocellular-Cholangiocarcinoma from Hepatocellular Carcinoma

  • Kim, Hyunghu;Kim, Seung-seob;Lee, Sunyoung;Lee, Myeongjee;Kim, Myeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.313-322
    • /
    • 2021
  • Purpose: To find diagnostic image features, to compare diagnostic performance of multiphase CT versus gadoxetic acid disodium-enhanced MRI (GAD-MRI), and to evaluate the impact of analyzing Liver Imaging Reporting and Data System (LI-RADS) imaging features, for distinguishing combined hepatocellular-cholangiocarcinoma (CHC) from hepatocellular carcinoma (HCC). Materials and Methods: Ninety-six patients with pathologically proven CHC (n = 48) or HCC (n = 48), diagnosed June 2008 to May 2018 were retrospectively analyzed in random order by three radiologists with different experience levels. In the first analysis, the readers independently determined the probability of CHC based on their own knowledge and experiences. In the second analysis, they evaluated imaging features defined in LI-RADS 2018. Area under the curve (AUC) values for CHC diagnosis were compared between CT and MRI, and between the first and second analyses. Interobserver agreement was assessed using Cohen's weighted κ values. Results: Targetoid LR-M image features showed better specificities and positive predictive values (PPV) than the others. Among them, rim arterial phase hyperenhancement had the highest specificity and PPV. Average sensitivity, specificity, and AUC values were higher for MRI than for CT in both the first (P = 0.008, 0.005, 0.002, respectively) and second (P = 0.017, 0.026, 0.036) analyses. Interobserver agreements were higher for MRI in both analyses (κ = 0.307 for CT, κ = 0.332 for MRI in the first analysis; κ = 0.467 for CT, κ = 0.531 for MRI in the second analysis), with greater agreement in the second analysis for both CT (P = 0.001) and MRI (P < 0.001). Conclusion: Rim arterial phase hyperenhancement on GAD-MRI can be a good indicator suggesting CHC more than HCC. GAD-MRI may provide greater accuracy than CT for distinguishing CHC from HCC. Interobserver agreement can be improved for both CT and MRI by analyzing LI-RADS imaging features.

Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology

  • Tanabodee, Jitraporn;Thepsuwan, Kitisak;Karalak, Anant;Laoaree, Orawan;Krachang, Anong;Manmatt, Kittipong;Anontwatanawong, Nualpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7381-7384
    • /
    • 2015
  • This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

Disagreement of ICD-10 Codes Between a Local Hospital Information System and a Cancer Registry

  • Sriplung, Hutcha;Kantipundee, Tirada;Tassanapitak, Cheamjit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권1호
    • /
    • pp.259-263
    • /
    • 2015
  • Background: In the field of cancer, the ICD-10 coding convention is based on the site of a neoplasm in the body and usually ignores the morphology, thus the same code may be assigned to tumors of different morphologic types in an organ. Nowadays, all general (provincial) and center hospitals in Thailand are equipped with the hospital information system (HIS) database. Objective: This study aimed to find the characteristics and magnitude of agreement represented by the positive predictive value (PPV) of provisional cancer diagnoses in the HIS database in Pattani Hospital in Thailand in comparison with the final cancer diagnosis of the ICD-10 codes generated from a well established cancer registry in Songklanagarind Hospital, the medical school hospital of Prince of Songkla University. Materials and Methods: Data on cancer patients residing in Pattani province who visited Pattani Hospital from January 2007 to May 2011 were obtained from the HIS database. The ICD-10 codes of the HIS computer database of Pattani Hospital were compared against the ICD-10 codes of the same person recorded in the hospital-based cancer registry of Songklanagarind Hospital. The degree of agreement or positive predictive value (PPV) was calculated for each sex and for both sexes combined. Results: A total of 313 cases (15.9%) could be matched in the two databases. Some 222 cases, 109 males and 113 females, fulfilled the criteria of referral from Pattani to Songklanagarind Hospitals. Of 109 male cancer cases, 76 had the same ICD-10 codes in both hospitals, thus, the PPV was 69.7% (95%CI: 60.2-78.2%). Agreement in 76 out of 113 females gave a PPV of 67.3% (95%CI: 57.8-75.8%). The two percentages were found non-significant with Fisher's exact p-value of 0.773. The PPV for combined cases of both sexes was 68.5% (95%CI: 61.9-74.5%). Conclusions: Changes in final diagnosis in the referral system are common, thus the summary statistics of a hospital without full investigation facilities must be used with care, as the statistics are biased towards simple diseases able to be investigated by available facilities. A systematic feedback of patient information from a tertiary to a referring hospital should be considered to increase the accuracy of statistics and to improve the comprehensive care of cancer patients.

Panoramic radiography can be an effective diagnostic tool adjunctive to oral examinations in the national health checkup program

  • Kweon, Helen Hye-In;Lee, Jae-Hong;Youk, Tae-mi;Lee, Bo-Ah;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제48권5호
    • /
    • pp.317-325
    • /
    • 2018
  • Purpose: We investigated correlations between the findings of oral examinations and panoramic radiography in order to determine the efficacy of using panoramic radiographs in screening examinations. Methods: This study included patients who visited dental clinics at National Health Insurance Service (NHIS) Ilsan Hospital for checkups during 2009-2015 and underwent panoramic radiographic examinations within 1 year prior to the oral examinations. Among the 48,006 patients who received checkups, 1,091 were included in this study. The data were evaluated using the Cohen kappa and interrater agreement coefficients. Accuracy, sensitivity, and specificity were calculated using data from the panoramic radiographs as true positive diagnoses. Results: The interrater agreement coefficient for occlusal caries was 28.8%, and the Cohen kappa coefficient was 0.043 between the oral and panoramic radiographic examinations. Root caries and subgingival calculus were only found on the radiographs, while gingival inflammation was found only by the oral examinations. The oral examinations had a specificity for detecting occlusal dental caries of 100%, while their sensitivity for proximal dental caries and supragingival calculus was extremely low (14.0% and 18.3%, respectively) compared to the panoramic radiographic examinations. The oral examinations showed a relatively low sensitivity of 66.2% and a specificity of 43.7% in detecting tooth loss compared with panoramic radiography. Conclusions: Panoramic radiography can provide information that is difficult to obtain in oral examinations, such as root caries, furcation involvement, and subgingival calculus, which are factors that can directly affect the survival rate of teeth. It therefore seems reasonable and necessary to add panoramic radiography to large-scale health checkup programs such as that provided by the NHIS.

Can indirect magnetic resonance arthrography be a good alternative to magnetic resonance imaging in diagnosing glenoid labrum lesions?: a prospective study

  • Mardani-Kivi, Mohsen;Alizadeh, Ahmad;Asadi, Kamran;Izadi, Amin;Leili, Ehsan Kazemnejad;arzpeyma, Sima Fallah
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.182-187
    • /
    • 2022
  • Background: This study was designed to evaluate and compare the diagnostic value of magnetic resonance imaging (MRI) and indirect magnetic resonance arthrography (I-MRA) imaging with those of arthroscopy and each other. Methods: This descriptive-analytical study was conducted in 2020. All patients who tested positive for labrum lesions during that year were included in the study. The patients underwent conservative treatment for 6 weeks. In the event of no response to conservative treatment, MRI and I-MRA imaging were conducted, and the patients underwent arthroscopy to determine their ultimate diagnosis and treatment plan. Imaging results were assessed at a 1-week interval by an experienced musculoskeletal radiologist. Image interpretation results and arthroscopy were recorded in the data collection form. Results: Overall, 35 patients comprised the study. Based on the kappa coefficient, the results indicate that the results of both imaging methods are in agreement with the arthroscopic findings, but the I-MRA consensus rate is higher than that of MRI (0.612±0.157 and 0.749±0.101 vs. 0.449±0.160 and 0.603±0.113). The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of MRI in detecting labrum tears were 77.77%, 75.00%, 91.30%, 50.00%, and 77.14%, respectively, and those of I-MRA were 88.88%, 75.00%, 92.30%, 66.66%, and 85.71%. Conclusions: Here, I-MRA showed higher diagnostic value than MRI for labral tears. Therefore, it is recommended that I-MRA be used instead of MRI if there is an indication for potential labrum lesions.

Application of Immunophenotyping and Heteroduplex Polymerase Chain Reaction (hPARR) for Diagnosis of Canine Lymphomas

  • Sirivisoot, Sirintra;Techangamsuwan, Somporn;Tangkawattana, Sirikachorn;Rungsipipat, Anudep
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권6호
    • /
    • pp.2909-2916
    • /
    • 2016
  • Background: Canine malignant lymphoma is classified into B- or T-cell origin, as in the human case. Due to differences in prognosis, a suitable method needs to be developed for lineage identification. Aims: To determine the accuracy of immunophenotypic and molecular information between three methods: immunocytochemistry (ICC), immunohistochemistry (IHC) and heteroduplex polymerase chain reaction for antigen receptor rearrangements (hPARR) in spontaneous canine lymphomas. Materials and Methods: Peripheral blood, fine needle aspiration and tissue biopsies from enlarged peripheral lymph nodes prior to treatment of 28 multicentric lymphoma patients were collected. Cytopathology and histopathology were examined and classified using the updated Kiel and WHO classifications, respectively. Anti-Pax5 and anti-CD3 antibodies as B- and T-cell markers were applied for immunophenotyping by ICC and IHC. Neoplastic lymphocytes from lymph node and white blood cell pellets from peripheral blood were evaluated by hPARR. Results: In this study, low grade B-cell lymphoma accounted for 25% (7/28), high grade B-cell lymphoma for 64.3% (18/28) and high grade T-cell lymphoma for 10.7% (3/28). According to the WHO classification, 50% of all cases were classified as diffuse large B-cell lymphoma. In addition, ICC showed concordant results with IHC; all B-cell lymphomas showed Pax5+/CD3, and all T-cell lymphomas exhibited Pax5-/CD3+. In contrast to hPARR, 12 B-cell lymphomas featured the IgH gene; seven presented the $TCR{\gamma}$ gene; five cases showed both IgH and $TCR{\gamma}$ genes, and one case were indeterminate. Three T-cell lymphomas showed the $TCR{\gamma}$ gene. The percentage agreement between hPARR and ICC/IHC was 60%. Conclusions: Immunophenotyping should not rely on a single method. ICC or IHC with hPARR should be used concurrently for immunophenotypic diagnosis in canine lymphomas.

MR diagnosis of cranial neuritis focusing on facial neuritis: Performance of contrast-enhanced 3D-FLAIR technique

  • Lee, Ho Kyu;Koh, Myeong Ju;Kim, Seung Hyoung;Oh, Jung-Hwan
    • Journal of Medicine and Life Science
    • /
    • 제16권1호
    • /
    • pp.1-5
    • /
    • 2019
  • Our purpose was to evaluate usefulness of the contrast-enhanced 3 dimensional fluid attenuated inversion recovery (3D-FLAIR) technique of half brain volume to diagnose the patients with facial neuritis based on segment-based analysis. We assessed retrospectively 17 consecutive patients who underwent brain MR imaging at 3 tesla for facial neuritis: 11 patients with idiopathic facial neuritis and 6 with herpes zoster oticus. Contrast enhanced 3D-FLAIR sequences of the half brain volume were analyzed and 3D T1-weighted sequence of the full brain volume were used as the base-line exam. Enhancement of the facial nerve was determined in each segment of 5 facial nerve segments by two radiologists. Sensitivity, specificity and accuracy of enhancement of each segment were assessed. The authors experienced a prompt fuzzy CSF enhancement in the fundus of the internal auditory canal in patients with enhancement of the canalicular segment. Interobserver agreement of CE 3D-FLAIR was excellent(${\kappa}$-value 0.885). Sensitivity, specificity, and accuracy of each segment are 1.0, 0.823, 0.912 in the canalicular segment; 0.118, 1.0, 0.559 in the labyrinthine segment; 0.823, 0.294, 0.559 in the anterior genu; 0.823, 0.529, 0.676 in the tympanic segment; 0.823, 0.235, 0.529 in the mastoid segment, respectively. In addition, those of prompt fuzzy enhancement were 0.647, 1.0, and 0.824, respectively. Incidence of prompt fuzzy enhancement with enhancement of the canalicular segment was 11 sites(55%): 6 (54.5%) in idiopathic facial neuritis and 5 (83.3%) in herpes zoster. Enhancement of the canalicular segment and prompt fuzzy enhancement on CE 3D-FLAIR was significantly correlated with occurrence of facial neuritis (p<0.001). CE 3D-FLAIR technique of the half brain volume is useful to evaluate the patients with facial neuritis as an adjunct sequence in addition to contrast-enhanced 3D T1-weighted sequence. On segment-based analysis, contrast enhancement of the canalicular segment is the most reliable. Prompt fuzzy enhancement is seen in not only herpes zoster, but in idiopathic facial neuritis.