• Title/Summary/Keyword: Accuracy Rate

Search Result 3,403, Processing Time 0.029 seconds

Research on Overheating Prediction Methods for Truck Braking Systems (화물차의 제동장치에서 발생하는 과열 예측방안 연구)

  • Beom Seok Chae;Young Jin Kim;Hyung Jin Kim
    • Smart Media Journal
    • /
    • v.13 no.6
    • /
    • pp.54-61
    • /
    • 2024
  • Recently, due to the increase in domestic and international online e-commerce platforms and the increase in container traffic at domestic ports, the operating ratio of large trucks has increased, and the number of truck fires is continuously increasing. In particular, spontaneous combustion is the most common cause of truck fires. Various academic approaches have been attempted to prevent truck fires, but due to the lack of research on the spontaneous tire ignition phenomenon that occurs during braking, this research directly designed and manufactured an experimental device to establish an environment similar to the braking system of a truck. A non-contact temperature sensor was installed on the brake device of the experimental device to collect temperature data generated from the brake device. Based on the data collected from the temperature sensor of the brake device and the temperature sensor on the tire surface, the ARIMA model among the time series prediction models was used to Appropriate parameters were selected to suit the temperature change trend, and as a result of comparing and analyzing the measured and predicted data, an accuracy of over 90% was obtained. Based on this, a plan was proposed to reduce the rate of fires in trucks by providing real-time warnings and support for truck drivers to respond to overheating phenomena occurring in the braking system.

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

A Study on the Availability of Spatial and Statistical Data for Assessing CO2 Absorption Rate in Forests - A Case Study on Ansan-si - (산림의 CO2 흡수량 평가를 위한 통계 및 공간자료의 활용성 검토 - 안산시를 대상으로 -)

  • Kim, Sunghoon;Kim, Ilkwon;Jun, Baysok;Kwon, Hyuksoo
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.124-138
    • /
    • 2018
  • This research was conducted to examine the availability of spatial data for assessing absorption rates of $CO_2$ in the forest of Ansan-si and evaluate the validity of methods that analyze $CO_2$ absorption. To statistically assess the $CO_2$ absorption rates per year, the 1:5,000 Digital Forest-Map (Lim5000) and Standard Carbon Removal of Major Forest Species (SCRMF) methods were employed. Furthermore, Land Cover Map (LCM) was also used to verify $CO_2$ absorption rate availability per year. Great variations in $CO_2$ absorption rates occurred before and after the year 2010. This was due to improvement in precision and accuracy of the Forest Basic Statistics (FBS) in 2010, which resulted in rapid increase in growing stock. Thus, calibration of data prior to 2010 is necessary, based on recent FBS standards. Previous studies that employed Lim5000 and FBS (2015, 2010) did not take into account the $CO_2$ absorption rates of different tree species, and the combination of SCRMF and Lim5000 resulted in $CO_2$ absorption of 42,369 ton. In contrast to the combination of SCRMF and Lim5000, LCM and SCRMF resulted in $CO_2$ absorption of 40,696 ton. Homoscedasticity tests for Lim5000 and LCM resulted in p-value <0.01, with a difference in $CO_2$ absorption of 1,673 ton. Given that $CO_2$ absorption in forests is an important factor that reduces greenhouse gas emissions, the findings of this study should provide fundamental information for supporting a wide range of decision-making processes for land use and management.

Simultaneous Determination of Non-steroidal Anti-inflammatory Drugs and Corticosteroids Added to Foods as Adulterants using LC-ESI-tandem Mass Spectrometry (LC/ESI-MS/MS를 이용한 식품 중 불법적으로 첨가된 비스테로이드성 소염진통제 및 스테로이드 의약품 동시분석)

  • Lee, Yongcheol;Park, Ju-Sung;Kim, Sung-Dan;Yang, Hye-Ran;Kim, Eun-Hee;Yi, Yun-Jung;Cho, Sung-Ja;Jo, Han-Bin;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.247-251
    • /
    • 2013
  • The objective of present study was to develop a simultaneous determination method of 5 medical compounds, including beclomethasone, dexamethasone, prednisolone, ketoprofen, phenylbutazone in foods, using LC-MS/MS. To optimize MS analytical condition of 5 compounds, each parameter was established by MRM mode. The chromatographic separation was achieved on a C18 column successfully, with a mobile phase made up of A (0.1% formic acid) and B (0.1% formic acid in acetonitrile), at a flow rate of 0.3 mL/min for 17 min with a gradient elution. LOD and LOQ of 5 compounds were in the range of 0.40~4.60 ng/mL and 0.81~11.46 ng/mL, respectively. As a result of analyzing the three concentrations of the standard mixture added to blank samples, the results showed that the mean recovery rate of 5 compounds was in the range of 81.52~103.83%, and RSD (%) of Intra- and Inter-day assay were 0.52-10.45. Since relatively fine selectivity, accuracy and reproducibility were shown in this qualified experimental method, it could be utilized efficiently to investigating those 5 compounds to see if it is added to food products illegally.

Development of a Predictive Model Describing the Growth of Listeria Monocytogenes in Fresh Cut Vegetable (샐러드용 신선 채소에서의 Listerio monocytogenes 성장예측모델 개발)

  • Cho, Joon-Il;Lee, Soon-Ho;Lim, Ji-Su;Kwak, Hyo-Sun;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • In this study, predictive mathematical models were developed to predict the kinetics of Listeria monocytogenes growth in the mixed fresh-cut vegetables, which is the most popular ready-to-eat food in the world, as a function of temperature (4, 10, 20 and $30^{\circ}C$). At the specified storage temperatures, the primary growth curve fit well ($r^2$=0.916~0.981) with a Gompertz and Baranyi equation to determine the specific growth rate (SGR). The Polynomial model for natural logarithm transformation of the SGR as a function of temperature was obtained by nonlinear regression (Prism, version 4.0, GraphPad Software). As the storage temperature decreased from $30^{\circ}C$ to $4^{\circ}C$, the SGR decreased, respectively. Polynomial model was identified as appropriate secondary model for SGR on the basis of most statistical indices such as mean square error (MSE=0.002718 by Gompertz, 0.055186 by Baranyi), bias factor (Bf=1.050084 by Gompertz, 1.931472 by Baranyi) and accuracy factor (Af=1.160767 by Gompertz, 2.137181 by Baranyi). Results indicate L. monocytogenes growth was affected by temperature mainly, and equation was developed by Gompertz model (-0.1606+$0.0574^*Temp$+$0.0009^*Temp^*Temp$) was more effective than equation was developed by Baranyi model (0.3502-$0.0496^*Temp$+$0.0022^*Temp^*Temp$) for specific growth rate prediction of L.monocytogenes in the mixed fresh-cut vegetables.

Global Temperature Trends of Lower Stratosphere Derived from the Microwave Satellite Observations and GCM Reanalyses (마이크로파 위성관측과 모델 재분석에서 조사된 전지구에 대한 하부 성층권 온도의 추세)

  • Yoo, Jung-Moon;Yoon, Sun-Kyung;Kim, Kyu-Myong
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.388-404
    • /
    • 2001
  • In order to examine the relative accuracy of satellite observations and model reanalyses about lower stratospheric temperature trends, two satellite-observed Microwave Sounding Unit (MSU) channel 4 (Ch 4) brightness temperature data and two GCM (ECMWF and GEOS) reanalyses during 1981${\sim}$1993 have been intercompared with the regression analysis of time series. The satellite data for the period of 1980${\sim}$1999 are MSU4 at nadir direction and SC4 at multiple scans, respectively, derived in this study and Spencer and Christy (1993). The MSU4 temperature over the globe during the above period shows the cooling trend of -0.35 K/decade, and the cooling over the global ocean is 1.2 times as much as that over the land. Lower stratospheric temperatures during the common period (1981${\sim}$1993) globally show the cooling in MSU4 (-0.14 K/decade), SC4 (-0.42 K/decade) and GEOS (-0.15 K/decade) which have strong annual cycles. However, ECMWF shows a little warming and weak annual cycle. The 95% confidence intervals of the lower stratospheric temperature trends are greater than those of midtropospheric (channel 2) trends, indicating less confidence in Ch 4. The lapse rate in the trend between the above two atmospheric layers is largest over the northern hemispheric land. MSU4 has low correlation with ECMWF over the globe, and high value with GEOS near the Korean peninsula. Lower correlations (r < 0.6) between MSU4 and SC4 (or ECMWF) occur over $30^{\circ}$N latitude belt, where subtropical jet stream passes. Temporal correlation among them over the globe is generally high (r > 0.6). Four kinds of lower stratospheric temperature data near the Korean peninsula commonly show cooling trends, of which the SC4 values (-0.82 K/decade) is the largest.

  • PDF

Perceptions of Quality Nursing care of Patients and Families (질적 간호에 대한 환자와 가족의 지각)

  • Chi, Sung-Ai;Kwon, Sung-Bok;Park, Eun-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.1
    • /
    • pp.247-275
    • /
    • 1998
  • The purpose of this study was to offer the results of content analysis and qualitative study that explored the perceptions about quality nursing care of patients and families as consumers and to identify the implications of this study for quality nursing care management and research. The data was collected from 12 adult patients and 9 families who were admmitted at medical and surgical nursing unit of one university hospital in Seoul from October, 1996 to January, 1997. Research participants were asked to response "what do you think quality nursing care?" and similar questions during the interviews was performed. Data were analyzed using open coding and content analysis with frequencies and percents of attributes of quality nursing care. Attributes of quality nursing care and meaning of quality nursing care that patients and families perceived were explored. 1. The attributes of quality nursing care that patient and families perceived were categorized into 56 attributes. The highest response rate among the attributes was 'one's heart at ease' (76.2%), and the next high response rates were ranked in order 'consideration' , 'care about' (each 61.9% 'expert skill' (57.1%), 'deal with problem promptly' , 'information offer' (42.9%), 'intimate feeling' (38.1%), 'smile' 'service spirit' , 'do one's best' (each 33.3%), 'frequent visit' (23.8%), 'observe the time' (23.8%), 'direct nursing care' , 'speaking warmly' , give a hope' , 'address kindly' , 'a sense of duty' , 'good facilities' (each 19.0%), 'inquire after a patient health' , 'patient-centered nursing care' , 'showing an example' , 'professional knowledge' , 'careless moraly patient' , 'give encourage to patients' , 'good answer a question' (each 14.3%), 'do not imprudently' , 'do not disregard' , 'broad knowledge' , 'emergency treatment skill' , 'dependability' ,'consolation' giving a sense of security' , 'a self sacrificing spirit' , 'a sense of responsibility' 'hard - working', 'enough disposition of nursing staff (each 9.5%), 'improve patient's pride' and the rest attributes exhibited 4.7%, respectively. 2. The attributes that were identified in patients' data only were 8 categories, 'service sprit' (58.3 %) 'expert knowledge' , 'good answer a question' (each 25.0%), 'hard working' (16.7%), 'a warm character', 'professional attainments', 'do without reserve', 'satisfaction' (each 8.3%), 3. The attributes were identified to families' data only were 31 categories, 'speaking warmly' , 'direct nursing care', 'adress kindly', 'patientcentered nursing care', 'showing an example' (each 33.3%). 'do not imprudently' , 'do not disregard' , 'consolation', 'giving a sense of security', 'broad knowledge' , 'emergency treatment skill', 'dependability' ,'a self - sacrificing spirit', 'a sense of responsibility' (each 22.2%), 'improve patient's pride' , 'without discrimination' , 'show kindness' , 'individual nursing care', 'being with patient' , 'helping' , 'accuracy' , 'without any mistake' , 'love' , 'self - confidence', 'self possession', 'a self - denying spirit' , 'a sense of duty' , 'tighten discipline' , 'disposed room with similar patient to diagnosis', 'compensatory relationship between me dical team' , 'role of connection' (each 11.1 %). 4. The attributes of quality nursing care were integrated into 11 categories that they were 'patientcentered nursing care' (25.1%), 'expertise' (22.1%), 'caring'(18.1%), 'kindness'(11.1%L 'nurse attainments(10.1%), 'sincerity' (7.5%), 'good environment' (2.0%), 'effective organizational management', 'coordination', 'enough nursing staff' ( each 1.0%), 'satisfaction' (0.5%) were showed in the order of the highest rate. 5. The concept of quality nursing care were defined as 'give a satisfaction to patients by patientcentered care based on professional skill and caring with kindness and sincerity'. The description of the meaning of quality nursing care provided by this research participants, patients and families can provide important information for quality nursing care management, medical marketing, education and researches of this field. On the basis of the above findings the following recommendations are made: to suggest to utilize this results for patient care in practice setting, development of quality assessment tool in nursing care, repeat study by the same subjects and method, and to a comparative study by the same method to nurse.

  • PDF

An Alternative Method for a Rapid Urease Test Using Back-table Gastric Mucosal Biopsies from Gastrectomy Specimen for Making the Diagnosis of Helicobacter pylori Infection in Patients with Gastric Cancer (위암 환자의 헬리코박터 파이로리 감염 진단에 있어서 위절제술 직후 생검된 위점막 조직을 이용한 신속 요소 분해 효소 검사법 도입의 의의)

  • Kim, Sin-Ill;Jin, Sung-Ho;Lee, Jae-Hwan;Min, Jae-Seok;Bang, Ho-Yoon;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.172-176
    • /
    • 2009
  • Purpose: The rapid urease test is a rapid and reliable method for diagnosing Helicobacter pylori infection. However it requires gastric mucosal biopsies during endoscopy, and the test is not covered by national health insurance for patients with gastric cancer. So, we introduced an alternative method for a rapid urease test using back-table gastric mucosal biopsies from gastrectomy specimen. Materials and Methods: Ninety gastric cancer patients underwent an anti H. pylori IgG ELISA test and gastrectomy. Just after gastrectomy, two gastric mucosal biopsies from the prepyloric antrum and lower body of the gastrectomy specimen were taken from the back table in the operative room, and these were fixed immediately with the rapid urease test kit, and the color change was monitored for up to 24 hours. In this study, H. pylori infection was defined as positive when the serology or rapid urease test showed positive results. Results: The positive rate of the rapid urease test and serology was 91.1% and 77.8%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of the rapid urease test and serology were 94.3 and 80.5%, 100 and 100%, 100 and 100%, and 37.5 and 15%, respectively. The accuracy of the rapid urease test was higher than that of serology (94.4 vs. 81.1%, respectively). The rapid urease test showed a higher rate of detecting H. pylori infection than that of serology (McNemar's test, P=0.019). Conclusion: The result of the rapid urease test using back-table gastric mucosal biopsies from a gastrectomy specimen is comparable to the reference data of the conventional rapid urease test using gastric mucosal endoscopic biopsies. Therefore, it can be an alternative diagnostic method for H. pylori infection.

  • PDF

The Dose Attenuation according to the Gantry Angle and the Photon Energy Using the Standard Exact Couch and the 6D Robotic Couch (Standard Exact Couch와 6D Robotic Couch를 이용한 광자선의 조사각에 따른 선량 감쇠에 대한 연구)

  • Kim, Tae Hyeong;Oh, Se An;Yea, Ji Woon;Park, Jae Won;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • The objective of this study is to increase the accuracy of dose transmission in radiation therapy using two types of treatment tables, standard exact couch (Varian 21EX, Varian Medical Systems, Milpitas, CA) and 6D robotic couch (Novalis, BrainLAB A.G., Heimstetten, Germany)). We examined the dose attenuation based on the two types of treatment tables and studied the dose of attenuation using the phase (In/Out) for the standard exact couch. We measured the relative dose according to the incident angle of a penetrative photon beam under a treatment table. The incident angle of the photon beam was from $0^{\circ}$ to $360^{\circ}$ in the increments of $5^{\circ}$. The reference angle was set to $0^{\circ}$. Furthermore, the relative dose of the 6D robotic couch was measured using 6 MV and 15 MV, and that of the standard exact couch was measured at the sliding rail position (In-Out) using 6 MV and 10 MV. In the case of the standard exact couch, the measured relative dose was 16.53% (rails at the "In position," $175^{\circ}$, 6 MV), 12.42% (rails at the "In position," $175^{\circ}$, 10 MV), 13.13% (rails at the "Out position," $175^{\circ}$, 6 MV), and 9.96% (rails at the "Out position," $175^{\circ}$, 10 MV). In the case of the 6D robotic couch, the measured relative dose was 6.82% ($130^{\circ}$, 6 MV) and 4.92% ($130^{\circ}$, 15 MV). The photon energies were surveyed at the same incident angle. The dose attenuation for an energy of 10 MV was 4~5% lower than that for 6 MV. This indicated that the higher photon energy, lesser is the attenuation. The results of this study indicated that the attenuation rate for the 6D robotic couch was confirmed to be 1% larger than that for the standard exact couch at 6 MV and $180^{\circ}$. In the case of the standard exact couch, the dose attenuation was found to change rapidly in accordance with the phase ("In position" and "Out position") of the sliding rail.