• 제목/요약/키워드: Accuracy Rate

검색결과 3,386건 처리시간 0.031초

전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가 (Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan)

  • 심동오;정우영;류재광;박철홍;김윤재
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

CT Angiography-Derived RECHARGE Score Predicts Successful Percutaneous Coronary Intervention in Patients with Chronic Total Occlusion

  • Jiahui Li;Rui Wang;Christian Tesche;U. Joseph Schoepf;Jonathan T. Pannell;Yi He;Rongchong Huang;Yalei Chen;Jianan Li;Xiantao Song
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.697-705
    • /
    • 2021
  • Objective: To investigate the feasibility and the accuracy of the coronary CT angiography (CCTA)-derived Registry of Crossboss and Hybrid procedures in France, the Netherlands, Belgium and United Kingdom (RECHARGE) score (RECHARGECCTA) for the prediction of procedural success and 30-minutes guidewire crossing in percutaneous coronary intervention (PCI) for chronic total occlusion (CTO). Materials and Methods: One hundred and twenty-four consecutive patients (mean age, 54 years; 79% male) with 131 CTO lesions who underwent CCTA before catheter angiography (CA) with CTO-PCI were retrospectively enrolled in this study. The RECHARGECCTA scores were calculated and compared with RECHARGECA and other CTA-based prediction scores, including Multicenter CTO Registry of Japan (J-CTO), CT Registry of CTO Revascularisation (CT-RECTOR), and Korean Multicenter CTO CT Registry (KCCT) scores. Results: The procedural success rate of the CTO-PCI procedures was 72%, and 61% of cases achieved the 30-minutes wire crossing. No significant difference was observed between the RECHARGECCTA score and the RECHARGECA score for procedural success (median 2 vs. median 2, p = 0.084). However, the RECHARGECCTA score was higher than the RECHARGECA score for the 30-minutes wire crossing (median 2 vs. median 1.5, p = 0.001). The areas under the curve (AUCs) of the RECHARGECCTA and RECHARGECA scores for predicting procedural success showed no statistical significance (0.718 vs. 0.757, p = 0.655). The sensitivity, specificity, positive predictive value, and the negative predictive value of the RECHARGECCTA scores of ≤ 2 for predictive procedural success were 78%, 60%, 43%, and 87%, respectively. The RECHARGECCTA score showed a discriminative performance that was comparable to those of the other CTA-based prediction scores (AUC = 0.718 vs. 0.665-0.717, all p > 0.05). Conclusion: The non-invasive RECHARGECCTA score performs better than the invasive determination for the prediction of the 30-minutes wire crossing of CTO-PCI. However, the RECHARGECCTA score may not replace other CTA-based prediction scores for predicting CTO-PCI success.

IoT 센서와 AI 카메라를 융합한 급경사지 상태 분석 시스템 개발 (Development of a Slope Condition Analysis System using IoT Sensors and AI Camera)

  • 이승주;정기연;이태훈;김영석
    • 한국지반신소재학회논문집
    • /
    • 제23권2호
    • /
    • pp.43-52
    • /
    • 2024
  • 최근 이상기후로 인한 급경사지 붕괴 위험이 증가되고 있으며, 급경사지 붕괴 위험의 사전 예측 및 경보 전파가 이루어지지 않아 인명과 재산 피해가 발생할 수 있다. 본 논문에서는 급경사지의 상태를 평가하기 위해 IoT 센서와 AI 기반 카메라를 융합한 급경사지 분석 시스템을 개발하였다. 시스템을 개발하기 위하여 급경사지 지반조건을 고려한 계측센서 하드웨어 및 펌웨어 설계, AI 기반 영상 분석 알고리즘 설계, 그리고 예·경보 솔루션 및 시스템 제작을 수행하였다. IoT 센서의 데이터와 AI 카메라 영상 분석을 통해 센서 데이터의 오차를 최소화하고, 데이터의 신뢰성을 향상시키고자 하였다. 또한 실제 급경사지에 적용하여 정확도(신뢰도)를 평가하였다. 그 결과, 센서 계측 오류는 0.1° 이내로 유지되었으며 계측 데이터의 전송률은 95%이상이었다. AI 기반의 영상 분석 시스템은 야간에도 부분 인식률 99%의 높은 성능을 나타내었다. 본 연구결과는 다양한 사회간접자본(SOC) 시설의 급경사지 상태 분석 및 스마트 유지관리 분야에도 적용할 수 있을 것으로 판단된다.

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.

동해 남서부 해역에서 $^{210}Pb$를 이용한 퇴적속도 추정 (Estimation of $^{210}Pb$-derived Sedimentation Rates in the Southwestern East Sea)

  • 한정희;최만식
    • 한국해양학회지:바다
    • /
    • 제12권4호
    • /
    • pp.273-279
    • /
    • 2007
  • 동해 남서부 해역 울릉분지 일대 대륙붕과 대륙사면에서 퇴적속도를 추정하기 위해 저배경방사능 우물형 고순도 게르마늄 감마선 검색기를 이용하여 $^{210}Pb$, $^{226}Ra$$^{137}Cs$를 측정하였다. 추정된 퇴적속도는 대륙붕에서 가장 높고 (0.6-1.1 cm/yr), 대륙붕의 정점 B1005로부터 외해로 갈수록 거리가 증가함에 따라 퇴적속도는 지수함수적으로 감소하여, 분지에서 0.2 cm/yr 이하로 계산되었다. $^{137}Cs$의 투과깊이을 이용하여 퇴적속도에 대한 퇴적 후 퇴적물 혼합작용의 영향을 평가한 결과, 정점 BS-1을 제외하고 다른 정점들에 대하여 퇴적속도 추정에서 생물교란의 영향이 미미하다고 판단되어, 추정된 퇴적속도는 이 지역의 퇴적속도를 잘 나타내고 있다고 판단되었다. 기존의 여러 연구들과 이 연구의 결과로부터 대한해협을 통해 공급된 퇴적물들이 한반도 동남해역 연안에 이르러 대륙붕지역에 주로 퇴적되며, 나머지는 한반도 동쪽 대륙사면과 분지에 퇴적되는 것으로 추정할 수 있다. 또한 $^{210}Pb$ 수직분포는 이 지역의 퇴적과정이 매우 복잡할 가능성을 제시한다.

미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용 (Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source)

  • 안우상;장원우;박성호;정상훈;조운갑;김영석;안승도
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.190-197
    • /
    • 2011
  • 고선량률 근접치료에 사용되는 상업용 선원과 치료계획 시스템들은 AAPM TG 43에서 권고하는 점 및 선 선원에 의해 선량분포를 계산한다. 하지만, 근접치료용 선원에 대한 인체 내의 정확한 선량계산을 위해서 3차원 부피의 선원을 고려하는 MC 기반의 선량계산 방법이 필요하다. 본 연구에서는 microSelectron HDR Ir-192 선원을 작은 부분으로 분할하여 계산하는 미소선원 적분법을 이용하여 기하학적 인수를 계산하였다. 또한, 범용 방사선 수송코드인 MCNPX를 사용하여 30 cm 직경의 구형 물 팬텀 내에서 선원의 선량률을 계산하여 비등방성함수와 반경선량함수를 구하였다. 그 결과를 MC 기반 광자 수송코드인 MCPT를 사용하여 계산한 Williamson의 결과와 비교 및 분석하였다. 미소선원 적분법과 선 선원 근사법에 따른 기하학적 인수는 $r{\geq}0.5cm$에서는 0.2% 이내에서 일치하였고 r=0.1 cm일 때 1.33%의 차이를 보였다. 본 연구에서 계산된 비등방성함수와 반경선량함수가 Williamson의 계산된 결과의 차이는 비등방성함수의 경우 r=0.25 cm에 서 2.33%의 가장 큰 R-RMSE를 보였고 $r{\geq}0.5cm$에서는 1% 미만의 R-RMSE를 보였다. 반경선량함수의 경우는 r=0.1~14.0 cm에서 0.46%의 R-RMSE를 보였다. 미소선원 적분법과 선 선원 근사법으로 계산한 기하학적 인수는 $r{\geq}0.1cm$에서 잘 일치하지만 3차원의 Ir-192 선원을 적용하여 계산한 미소선원 적분법이 실제 기하학적 인수를 잘 반영할 것으로 생각된다. r=0.25 cm에서 비등방성함수를 제외하고는 MCPT와 MCNPX의 몬테칼로 코드를 이용하여 얻어진 비등방성함수와 반경선량함수는 각각의 몬테칼로 코드에 대한 불확실성 이내에서 잘 일치함을 확인하였다. 따라서 MCNPX 전산모사 결과를 통해 TG-43의 선량 계산식에 사용된 인자를 Williamson 등의 결과와 비교 및 검증함으로써, 추후 다른 종류의 선원에 대해서도 Monte Carlo 기반의 연구가 가능할 것으로 기대된다.

사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정 (Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR)

  • 김정호;오주현;정용안;유이령;손형선;김성훈;정수교;이형구
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권1호
    • /
    • pp.33-39
    • /
    • 2006
  • 목적 : 다중 채혈 이중지수법을 이용한 사구체여과율의 계산에 정확도와 편리성을 고려한 적정 채혈 횟수 및 시간을 선정하고자 하였다. 대상 및 방법 :총 34명의 환자를 대상으로 하였다. $^{99m}Tc$-DTPA 3 mCi를 정맥주사 후, 총 9회, 각각 5 ml의 혈액을 채혈하였다. 혈장의 방사능을 감마카운터에서 측정하여 이중지수 분석법으로 사구체여과율을 계산하였고 체표 면적으로 보정하였다. 두 가지 시간대의 혈장 방사능을 이용한 15 조합의 2회 채혈 사구체여과율을 계산하였고 10 조합의 3회 채혈 사구체여과율과 12 조합의 4회 채혈 사구체여과율 또한 계산하였다. 계산된 각각의 사구체여과율들과 기준값인 9회 채혈 사구체여과율의 일치도는 Kendall $\tau$ 상관 계수, 그리고 기준값과의 평균차와 표준편차를 이용하여 분석하였다. 결과: 2회 채혈 사구체 여과율은 높은 상관관계를 보이더라도 신기능의 변화에 따라 과대 또는 과소 평가되는 오류가 발생하였다. 3회 채혈 사구체여과율 중, 10-120-240분의 3회 채혈 사구체여과율이 높은 상관관계를 보이며 신기능의 변화에도 오류의 발생이 매우 적었다. 4회 채혈 사구체여과율은 3회 채혈 사구체여과율과 비교하여 정확성이 우월하지는 않았다. 결론: 신기능의 변화에도 불구하고 오류의 발생이 적은 10-120-240분의 3회 채혈 사구체여과율을 이용하여 환자의 신기능을 가장 정확하게 평가할 수 있을 것이다.

산림의 CO2 흡수량 평가를 위한 통계 및 공간자료의 활용성 검토 - 안산시를 대상으로 - (A Study on the Availability of Spatial and Statistical Data for Assessing CO2 Absorption Rate in Forests - A Case Study on Ansan-si -)

  • 김성훈;김일권;전배석;권혁수
    • 환경영향평가
    • /
    • 제27권2호
    • /
    • pp.124-138
    • /
    • 2018
  • 본 연구는 안산시 산림을 대상으로 연간 $CO_2$ 흡수량 평가를 위한 통계 및 공간자료의 활용성을 검토하였다. 통계자료, 임상도(1:5,000), 산림수종 표준 탄소흡수량 자료들을 활용해 산림의 연간 $CO_2$ 흡수량을 산정하였다. 또한 세분류토지피복도를 이용한 연간 $CO_2$ 흡수량 분석 및 활용성을 검증하였다. 통계자료를 이용한 경우 2010년을 기준으로 연간 $CO_2$ 흡수량의 차이가 컸다. 이는 2010년부터 산림기본통계의 작성 방법이 고도화됨에 따라 임목축적이 급격히 증가한 결과이다. 향후 통계자료를 활용할 경우 최근의 산림기본통계를 이용한 보정이 필요하다. 임상도(1:5,000)와 산림기본통계(2015, 2010)의 시기 차이를 이용한 방법은 수종들의 생장량에 따른 $CO_2$ 흡수량이 반영되지 않았다. 산림수종 표준 탄소흡수량 자료와 임상도(1:5,000)를 이용한 결과 연간 42,369 ton을 흡수하였다. 세분류토지피복도와 산림수종 표준탄소흡수량 자료를 이용한 결과는 40,696 ton이었다. 임상도(1:5,000)를 이용하여 세분류토지피복도를 검증한 결과 p<0.01 수준에서 유의했고, 흡수량 차이는 1,673 ton이었다. 본 연구는 다양한 산림활동의 온실가스 감축 효과 평가에 있어 객관적 기준을 적용하는 일환으로서 의의를 지닌다. 나아가 탄소흡수원과 관련된 토지이용 및 관리 등의 의사결정 지원을 위한 기초자료로 활용이 가능할 것이다.

LC/ESI-MS/MS를 이용한 식품 중 불법적으로 첨가된 비스테로이드성 소염진통제 및 스테로이드 의약품 동시분석 (Simultaneous Determination of Non-steroidal Anti-inflammatory Drugs and Corticosteroids Added to Foods as Adulterants using LC-ESI-tandem Mass Spectrometry)

  • 이용철;박주성;김성단;양혜란;김은희;이윤정;조성자;조한빈;김정헌;채영주
    • 한국식품위생안전성학회지
    • /
    • 제28권3호
    • /
    • pp.247-251
    • /
    • 2013
  • 소염 진통 의약품 성분인 beclomethasone, dexamethasone, prednisolone, ketoprofen, phenylbutazone 5종에 대한 동시분석을 위해 LC-MS/MS 분석 조건 중 MRM 방식으로 각 성분의 MS 분석 최적조건을 결정하고, 정량이온으로 beclomethasone 409.1/391.0, dexamethasone은 393.1/372.9, prednisolone은 361.0/343.1, ketoprofen은 255.0/209.0, phenylbutazone은 309.1/160.1을 분석하였다. 혼합표준용액을 기울기용매 조건으로 이동상 A(0.1% 개미산), B(0.1% 개미산을 함유한 아세토니트릴)를 이용하여 17분 동안 분석한 결과, prednisolone ($t_R$: 7.34 min), dexamethasone ($t_R$: 7.73 min), beclomethasone ($t_R$: 7.82 min), phenylbutazone($t_R$: 8.31 min), ketoprofen ($t_R$: 9.24 min) 순서로 검출되었다. 5종 성분 모두 약 2-100 ng/mL 농도 수준의 검정곡선에서 $R^2$ 값이 0.999 이상의 우수한 직선성을 나타내었고, prednisolone을 제외한 4종 성분의 검출한계는 0.4-0.9 ng/mL, 정량한계는 0.81-2.22 ng/mL 였으며, prednisolone은 그보다 다소 높은 4.60, 11.46 ng/mL 이었다. 환제품의 기타가공품 공시료에 5종 성분 혼합표준용액을 최종농도가 5, 20, 50 ng/mL이 되도록 직접 첨가하여 분석한 결과, 모든 농도에서 80% 이상의 우수한 회수율을 얻을 수 있었고, 일내 일간 반복 분석의 상대표준편차(%)를 통해 모든 성분에서 비교적 재현성 있는 결과가 나타났다. 실제 인터넷 상에서 유통중인 식품에 이 분석법을 적용한 결과 모든 제품에서 검출되진 않았으나, 소비자들의 건강상 위해를 끼칠 수 있는 이들 성분의 동시분석법을 활용한 지속적인 모니터링이 필요한 실정이다.

샐러드용 신선 채소에서의 Listerio monocytogenes 성장예측모델 개발 (Development of a Predictive Model Describing the Growth of Listeria Monocytogenes in Fresh Cut Vegetable)

  • 조준일;이순호;임지수;곽효선;황인균
    • 한국식품위생안전성학회지
    • /
    • 제26권1호
    • /
    • pp.25-30
    • /
    • 2011
  • 본 연구에서는 식중독 예방과 식품의 안전성 확보 및 정량적 미생물 위해평가에 활용하기위하여, Gompertz model과 Baranyi model을 이용하여 샐러드용 신선채소에서 L. monocytogenes의 SGR에 관한 성징예측모델(SGR by Gompertz equation=-0.1606+$0.0574^*Temp$+$0.0009^*Temp^*Temp$, SGR by Baranyi equation=0.3502-$0.0496^*Temp$+$0.0022^*Temp^*Temp$)을 개발하였다. 개발된 모델의 적합성 평가를 위해 MSE, Bf, 및 Af factor를 산출하였다. 샐러드용 신선 채소의 MSE, Bf, Af는 Gompertz model식을 적용한 경우 0.002718, 1.050084, 1.160767, Baranyi model 식을 적용한 경우 0.055186, 1.931472, 2.137181으로 나타나 Gompertz model식을 적용하여 개발한 예측모델이 Baranyi model 식을 이용하여 개발한 예측모델에 비해 적합성이 높은 것으로 나타났다. Gompertz model식을 활용하여 본 연구에서 개발된 샐러드용 신선 채소에서의 L. monocytogenes 성장 예측모델은 신선 채소류를 생산, 가공, 보관 및 판매하는 산업체에서 널리 활용 가능할 것으로 판단되며, 더욱 정확한 예측모델 개발을 위해서는 pH 및 수분활성도 등 다양한 변수에 따른 미생물의 성장패턴 변화 등에 관한 연구가 추가적으로 시행되어야 할 것으로 생각되어 진다.