• Title/Summary/Keyword: Accuracy Rate

Search Result 3,386, Processing Time 0.035 seconds

Usefulness of a Alvarado Scoring System for the Diagnosis of Acute Appendicitis in Children (소아 충수돌기염 진단에서 Alvarado Scoring System의 유용성)

  • Yang, Eun Seok;Yoon, Sung Kwan;Kim, Eun Young;Rho, Young Il;Park, Sang Kee;Park, Yeong Bong;Mun, Gyeong-Rae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • Purpose: Alvarado scoring system was evaluated regarding its usefulness for the early diagnosis of acute appendicitis in adult and in reduction of the incidence of negative appendicectomies. To evaluate the accuracy of diagnosing appendicitis using the Alvarado score in children. Methods: Prospectively, we surveyed 122 patients (male 67, female 55) suffering from abdominal pain, who had visited to the emergency department of Chosun University Hospital from June 2002 to May 2003. The Alvarado score has been computed from the white blood cell count, neutrophil count, body temperature, resistance in the right lower quadrant, length of symptoms, nausea and vomiting. Each patient was evaluated by a pediatric resident and then by a general surgeon independently. Results: Out of 170 total children who visited to the emergency department due to abdominal pain, 122 patients were associated with appendicitis. A total of 122 patients (67 male and 55 female) were visited to the emergency room with suspected appendicitis. From 105 operated patients, 92 (87.6%) were diagnosed acute appendicitis and erronous diagnostic rate was 12.4%, pathologically. Mean alvarado score of appendicitis group was $5.40{\pm}1.24$ whereas those of non-appendicitis group was $3.73{\pm}1.82$ (p<0.05). From 6 Alvarado score high sensitivity (86.4%) and high specificity (80.0%) were observed. Sensitivity of ultrasonography or computed tomography was 92.5%. Conclusion: We found that Alvarado score system is a noninvasive, safe diagnostic method, which is simple, reliable and repeatable. Alvarado score is useful system for a first, rapid and economic evaluation for the appendicitis in children.

  • PDF

Habitat Distribution Change Prediction of Asiatic Black Bears (Ursus thibetanus) Using Maxent Modeling Approach (Maxent 모델을 이용한 반달가슴곰의 서식지 분포변화 예측)

  • Kim, Tae-Geun;Yang, DooHa;Cho, YoungHo;Song, Kyo-Hong;Oh, Jang-Geun
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.197-207
    • /
    • 2016
  • This study aims at providing basic data to objectively evaluate the areas suitable for reintroduction of the species of Asiatic black bear (Ursus thibetanus) in order to effectively preserve the Asiatic black bears in the Korean protection areas including national parks, and for the species restoration success. To this end, this study predicted the potential habitats in East Asia, Southeast Asia and India, where there are the records of Asiatic black bears' appearances using the Maxent model and environmental variables related with climate, topography, road and land use. In addition, this study evaluated the effects of the relevant climate and environmental variables. This study also analyzed inhabitation range area suitable for Asiatic black and geographic change according to future climate change. As for the judgment accuracy of the Maxent model widely utilized for habitat distribution research of wildlife for preservation, AUC value was calculated as 0.893 (sd=0.121). This was useful in predicting Asiatic black bears' potential habitat and evaluate the habitat change characteristics according to future climate change. Compare to the distribution map of Asiatic black bears evaluated by IUCN, Habitat suitability by the Maxent model were regionally diverse in extant areas and low in the extinct areas from IUCN map. This can be the result reflecting the regional difference in the environmental conditions where Asiatic black bears inhabit. As for the environment affecting the potential habitat distribution of Asiatic black bears, inhabitation rate was the highest, according to land coverage type, compared to climate, topography and artificial factors like distance from road. Especially, the area of deciduous broadleaf forest was predicted to be preferred, in comparison with other land coverage types. Annual mean precipitation and the precipitation during the driest period were projected to affect more than temperature's annual range, and the inhabitation possibility was higher, as distance was farther from road. The reason is that Asiatic black bears are conjectured to prefer more stable area without human's intervention, as well as prey resource. The inhabitation range was predicted to be expanded gradually to the southern part of India, China's southeast coast and adjacent inland area, and Vietnam, Laos and Malaysia in the eastern coastal areas of Southeast Asia. The following areas are forecast to be the core areas, where Asiatic black bears can inhabit in the Asian region: Jeonnam, Jeonbuk and Gangwon areas in South Korea, Kyushu, Chugoku, Shikoku, Chubu, Kanto and Tohoku's border area in Japan, and Jiangxi, Zhejiang and Fujian border area in China. This study is expected to be used as basic data for the preservation and efficient management of Asiatic black bear's habitat, artificially introduced individual bear's release area selection, and the management of collision zones with humans.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Real-time Reverse Transcription Polymerase Chain Reaction Using Total RNA Extracted from Nasopharyngeal Aspirates for Detection of Pneumococcal Carriage in Children (소아에서 폐렴구균 집락률 측정을 위해 비인두 흡인 물의 총 RNA를 이용한 실시간 중합효소 연쇄반응법)

  • Kim, Young Kwang;Lee, Kyoung Hoon;Yun, Ki Wook;Lee, Mi Kyung;Lim, In Seok
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: Monitoring pneumococcal carriage rates is important. We developed and evaluated the accuracy of a real-time reverse transcription polymerase chain reaction (RT-PCR) protocol for the detection of Streptococcus pneumoniae. Methods: In October 2014, 157 nasopharyngeal aspirates were collected from patients aged <18 years admitted to Chung-Ang University Hospital. We developed and evaluated a real-time PCR method for detecting S. pneumoniae by comparing culture findings with the results of the real-time PCR using genomic DNA (gDNA). Of 157 samples, 20 specimens were analyzed in order to compare the results of cultures, real-time PCR, and real-time RT-PCR. Results: The concordance rate between culture findings and the results of real-time PCR was 0.922 (P<0.01, Fisher exact test). The 133 culture-negative samples were confirmed to be negative for S. pneumoniae using real-time PCR. Of the remaining 24 culture-positive samples, 21 were identified as S. pneumonia -positive using real-time PCR. The results of real-time RT-PCR and real-time PCR from 20 specimens were consistent with culture findings for all S. pneumoniae -positive samples except one. Culture and real-time RT-PCR required 26.5 and 4.5 hours to perform, respectively. Conclusions: This study established a real-time RT-PCR method for the detection of pneumococcal carriage in the nasopharynx. Real-time RT-PCR is an accurate, convenient, and time-saving method; therefore, it may be useful for collecting epidemiologic data regarding pneumococcal carriage in children.

Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy (경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가)

  • Chung, Hyun-Woo;Choi, Joon-Young;Kim, Young-Wook;Kim, Dong-Ik;Do, Young-Soo;Lee, Eun-Jeong;Lee, Su-Jin;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.316-321
    • /
    • 2006
  • Purpose: Differential diagnosis between arteriovenous (AVMs) aud non-arteriovenous malformations (nAVMs) is important in patients with congenital vascular malformations, because AVMs can cause hemodynamic alteration and require immediate treatment. We investigated whether transarterial lung perfusion scintigraphy (TLPS) was useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities. Materials and Methods: Fifty-seven patients (M:F=26:31, $21{\pm}13$ yr, 9 upper and 48 lower extremities) suspected of congenital vascular malformations in extremities underwent TLPS using $^{99m}Tc-MAA$ before embolization/sclerotherapy. Dose-corrected shunt fraction (SF) was calculated from time-activity curve of the lung. Final diagnosis of AVMs was determined by angiography. in patients with AVMs, follow-up TLPS was done for post-therapeutic evaluation. Results: Sixteen patients (8 upper and 8 lower extremities) had AVMs, while the remaining 41 had nAVMs (1 upper and 40 lower extremities). The mean SF of AVMs on TLPS was significantly higher than that of nAVMs ($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$), p=0.003). The sensitivity, specificity, and accuracy of TLPS (cut-off of SF = 20.0%) in diagnosis of AVMs before treatment were 93.8% (15/16), 100% (41/41) and 98.2% (56/57), respectively. The follow-up TLPS and angiography for post-therapeutic evaluation showed concordant results in 13 of 16 patients (81.3%) with AVMs. The mean SF of TLPS was significantly decreased after embolization/sclerotherapy ($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p=0.01). Conclusion: TLPS provides hemodynamic information of AVMs in extremities semiquantitatively. Furthermore, the results of TLPS showed a high concordance rate with angiographic findings. Therefore, TLPS is useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities.

Comparative Study on the Estimation of CO2 absorption Equilibrium in Methanol using PC-SAFT equation of state and Two-model approach. (메탄올의 이산화탄소 흡수평형 추산에 대한 PC-SAFT모델식과 Two-model approach 모델식의 비교연구)

  • Noh, Jaehyun;Park, Hoey Kyung;Kim, Dongsun;Cho, Jungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.136-152
    • /
    • 2017
  • The thermodynamic models, PC-SAFT (Perturbed-Chain Statistical Associated Fluid Theory) state equation and the Two-model approach liquid activity coefficient model NRTL (Non Random Two Liquid) + Henry + Peng-Robinson, for modeling the Rectisol process using methanol aqueous solution as the $CO_2$ removal solvent were compared. In addition, to determine the new binary interaction parameters of the PC-SAFT state equations and the Henry's constant of the two-model approach, absorption equilibrium experiments between carbon dioxide and methanol at 273.25K and 262.35K were carried out and regression analysis was performed. The accuracy of the newly determined parameters was verified through the regression results of the experimental data. These model equations and validated parameters were used to model the carbon dioxide removal process. In the case of using the two-model approach, the methanol solvent flow rate required to remove 99.00% of $CO_2$ was estimated to be approximately 43.72% higher, the cooling water consumption in the distillation tower was 39.22% higher, and the steam consumption was 43.09% higher than that using PC-SAFT EOS. In conclusion, the Rectisol process operating under high pressure was designed to be larger than that using the PC-SAFT state equation when modeled using the liquid activity coefficient model equation with Henry's relation. For this reason, if the quantity of low-solubility gas components dissolved in a liquid at a constant temperature is proportional to the partial pressure of the gas phase, the carbon dioxide with high solubility in methanol does not predict the absorption characteristics between methanol and carbon dioxide.

Biomass and Net Production of a Natural Quercus variabilis Forest and a Populus alba × P. glandulosa Plantation at Mt. Mohu Area in Chonnam (전남(全南) 모후산지역(母后山地域) 굴참나무천연림(天然林)과 현사시나무인공림(人工林)의 물질생산(物質生産)에 관(關)한 연구(硏究))

  • Choi, Young Cheol;Park, In Hyeop
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.2
    • /
    • pp.188-194
    • /
    • 1993
  • A natural Quercus variabilis forest and a Populus alba${\times}$P. glandulosa plantation in Mt. Mohu area were studied to investigate aboveground biomass and net production. A $20m{\times}30m$ quadrat was set up in each stand, and 10 sample trees each of Quercus variabilis and Populus alba ${\times}$ P. glandulosa were cut for dimension analysis. There was little difference in accuracy among three biomass regression models of logWt=A+BlogD, $logWt=A+BlogD^2H$, and logWt=A+BlogD+ClogH, where Wt. D, and H were dry weight, DBH, and height, respectively. Aboveground total biomass of Quercus variabilis stand was 31,275kg/ha, and that of Populus alba ${\times}$ P. glandulosa was 55,581kg/ha. In both of Quercus variabilis stand and Populus alba ${\times}$ P. glandulosa stand, the proportion of each tree component to abovegound total biomass was high in order of stem wood, branches, stem bark, and leaves. Quercus variabilis stand was higher in the proportion of stem bark, branches and leaves than Populus alba ${\times}$ P. glandulosa stand, while the former was lower in that of stem wood than the latter. Aboveground total net production of Quercus variabilis stand was 4,267kg/ha/yr., and that of Populus alba ${\times}$ P. glandulosa stand was 3,903kg/ha/yr. The proportion of each tree component to aboveground total net production of Quercus variabilis stand was high in order of leaves, stem wood, branches, and stem bark. That of Populus alba ${\times}$ P. glandulosa stand was high in order of stem wood, leaves, branches, and stem bark. Net assimilation rate and efficiency of leaf to produce stem of Quercus variabilis stand were 2.121 and 0.840, respectively. Those of Populus alba ${\times}$ P. glandulosa stand were 3.376 and 2.085, respectively. Though Populus alba${\times}$P. glandulosa stand was lower in aboveground total net production than Quercus variabilis stand, the former was higher in aboveground total biomass than the latter. The reason was that Populus alba${\times}$P. glandulosa stand was higher in net production of stem wood of accumulation organs than Quercus variablis stand.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Study on the Acceptability and Effectiveness of an Oral Contraceptive Among Iud Drop-outs in Rural Korea

  • Yang, J.M.;Bang, S.;Song, S.W.;Youn, B.B.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.51-66
    • /
    • 1968
  • During a period of about one year(November '66 to December '67), the Yonsei University College of Medicine conducted a field trial of the oral contraceptive(Ovulen) in order to study its acceptability and use-effectiveness among IUD drop-outs in Koyang county. We can summarize the outstanding findings from this investigation as follows; 1. 61.4% of the IUD drop-outs interviewed (911 women) wanted to use the pill. Most of the reasons for not wanting to use it(352 women) pertained to either use of other contraceptive methods(98) or subfecundity(150) following IUD terminations. Only 83 out of 911 women gave reasons related to the difficulty of obtaining pills. Therefore, we can state that most IUD drop-outs if still in need of a contraceptive methods are in favor of trying the pill, and especially so if this method is conveniently available. 2. The 467 women or 37% of those who terminated IUD use actually visited the clinic for medical screening, and only 11 of them or 2.4% were rejected because of pregnancy and other medical reasons such as cervical erosion, myoma, breast mass, etc. 5.5% or 25 of the 456 women who received the first cycle did not take a single pill during the study period. 3. When we defined those 431 women who accepted and took one or more tablets we found that women over age 30, with 4 or more children, and/or with a higher educational level were the best prospects for recruitment. 4. In accuracy of use, about two thirds of the users started taking the pill on the 5 th day as directed for the first three cycles, but the percentages rose sharply to about 80% in later cycles. Tardiness in starting pill use in the first cycle may have occurred partly because they had to return to the clinic monthly to get each new cycle. Among acceptors who did not quit between cycles, 80 to 90% were regular users, missing two or less tablets in each cycle. 5) More than 60% of the users felt well and sometimes lost their pre-acceptance symptoms. especially dysmenorrhea. However, 27.4% (58 women) had side effects attributable to the pill compund as nausea, vomiting, indigestion, breast tenderness, decreased lactation or breakthrough bleeding. 25.0% (53 women) also complained of medical diseases or symptoms not related to the pill, especially during the first three cycles. However, as the confidence and experience of the client and the field workers grew, the incidence of unrelated medical complaints quickly fell to a lower level in the later cycles. 6. As of the end of this study, on December 31, 1967, 49.2% (212 women) had discontinued the use of the pill for medical reasons as well as for the non medical reasons. Only one case terminated use due to a pregnancy after taking pills. The cumulative continuation rates (by the life table method), were 58.9%, 51.9%, 41.0% at the end of 3 months, 6 months and one year, respectively. These rates are lower than in the U.S. studies. Even when we add the retaking group to the first segment, the continuation rate goes up only about 5% above the first segment rates mentioned above. Possible explanations are different dosages, the newerness of the method and the use of only one point for pill distribution in the country together with a monthly return for cycle 1, 2, 3, and 4-6.

  • PDF

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.