• Title/Summary/Keyword: Accuracy Rate

Search Result 3,386, Processing Time 0.026 seconds

An Efficient Symbol Timing Synchronization Scheme for IEEE 802.11n MIMO-OFDM based WLAN Systems (IEEE 802.11n MIMO-OFDM 기반 무선 LAN 시스템을 위한 효율적인 심볼 동기 방법)

  • Cho, Mi-Suk;Jung, Yun-Ho;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.5
    • /
    • pp.95-103
    • /
    • 2009
  • An efficient symbol time synchronization scheme for IEEE 802.11n MIMO-OFDM based WLAN systems using cyclic shift diversity (CSD) preamble is proposed. CSD is used to prevent unintentional beamforming when the same preamble signal is transmitted through transmit antennas. However, it is difficult to find a proper starting-point of the OFDM symbol with the conventional algorithms because of time offset by multi-peaks which are result from cross-correlation of received CSD preamble with a known short training symbol. In addition, the performance of symbol time sync. is affected by AGC and packet detection position. In this paper, an optimal symbol time synch. algorithm which is composed of the boundary detection scheme between LTS and OFDM symbols, the verification scheme for enhancement of boundary detection accuracy, and the SNR-varying threshold estimation scheme is proposed. Simulation result show that the proposed algorithm has performance gains of 4.3dB in SNR compared to the conventional algorithms at the rate of 1% sync. failure probability for $2{\times}2$ MIMO-OFDM system and 18dB at 0.1% when maximum frequency offset exists. It also can be applied to $4{\times}4$ MIMO-OFDM system without any modification. Hence, it is very suitable for MIMO-OFDM WLAN systems using CSD preamble.

Usefulness of a FDG-PET Scan in Assessing Recurrent Gastric Cancer (재발한 위암의 진단에 사용된 FDG-PET의 유용성)

  • Lee Hyeon Kook;Lee Kyu Eun;Kim Yoon Ho;Jeong Jae Min;Yang Han-Kwang;Chung June Key;Lee Kuhn Uk;Choe Kuk Jin
    • Journal of Gastric Cancer
    • /
    • v.1 no.3
    • /
    • pp.174-179
    • /
    • 2001
  • Purpose: For curative resection of recurrent gastric cancer, it is imperative that there be no unrecognized foci of tumoral disease outside the operation field. PET (positron emission tomography) with FDG (18 fluoro-2 deoxy-D-glucose) is a whole-body imaging technique that exploits the increased rate of glycolysis in tumor cells to detect disease. The authors evaluated the usefulness of FDG-PET in assessing resectability of recurrent gastric cancer. Materials and Methods: Seven patients with recurrent gastric cancer were studied with FDG-PET from December 1998 to October 2000. All FDG-PET images were interpreted in conjunction with conventional diagnostic methods. All imaging results were correlated with the pathological diagnosis and clinical outcome. Results: A final diagnosis of recurrence was obtained at 14 sites in all 7 patients by histology or clinical follow up. Locoregional recurrence, including distant metastasis, developed in 6 of 7 patients and distant recurrence in only one. FDG-PET detected all recurrent sites (5 locoregional and 5 distant) in 5 patients without peritoneal recurrence, but did not detect peritoneal seeding in 2 patients with peritoneal recurrence. The accuracy of FDG-PET in estimating resectability was $71.4\%$ (5/7), and that of CT and PET together was $85.7\%$ (6/7). A curative resection could be performed in three of the recurrent patients (2 locoregional and 1 distant recurrence). Conclusion: Our results suggest that FDG-PET may be useful for detecting locoregional and distant recurrence of gastric cancer and for selecting appropriate treatment. However, considering that FDG-PET was limited in detecting peritoneal seeding and determining the exact anatomical extension of tumor, it should be used in conjunction with other anatomical images.

  • PDF

CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy

  • Jeon, Min-Cheol;Kim, Ju Ock;Jung, Sung Soo;Park, Hee Sun;Lee, Jeong Eun;Moon, Jae Young;Chung, Chae Uk;Kang, Da Hyun;Park, Dong Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.330-338
    • /
    • 2018
  • Background: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. Methods: We retrospectively analyzed the medical records of 244 patients who underwent CT-guided PTNB using our additional laser guidance system from July 1, 2015, to January 20, 2016. Results: There were nine false-negative results among the 238 total cases. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of our system for diagnosing malignancy were 94.4% (152/161), 100% (77/77), 100% (152/152), 89.5% (77/86), and 96.2% (229/238), respectively. The results of univariate analysis showed that the risk factors for a false-negative result were male sex (p=0.029), a final diagnosis of malignancy (p=0.033), a lesion in the lower lobe (p=0.035), shorter distance from the skin to the target lesion (p=0.003), and shorter distance from the pleura to the target lesion (p=0.006). The overall complication rate was 30.5% (74/243). Pneumothorax, hemoptysis, and hemothorax occurred in 21.8% (53/243), 9.1% (22/243), and 1.6% (4/243) of cases, respectively. Conclusion: The additional laser guidance system might be a highly economical and efficient method to improve the diagnostic efficacy and safety of conventional CT-guided PTNB even if performed by inexperienced pulmonologists.

Vibration Analysis of SAR Antenna Reflectors During Satellite Maneuver (위성 기동 시 SAR 안테나 반사판에 발생하는 진동 분석)

  • Kim, Tae-Hyun;Kim, Dae-Yeon;Suh, Jong-Eun;Han, Jae-Hung;Lee, Jae-Eun;Jung, Hwa-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.3
    • /
    • pp.225-231
    • /
    • 2020
  • Recently, there has been an increasing demand for SAR satellite as it can be operated regardless of the weather condition. In general, main reflector of the SAR is formed of multiple deployable panels to increase performance in the constrained payload envelope. By nature, deployable structure lacks structural stiffness and it is vulnerable to external disturbances and excitation. In particular, SAR satellites may have high levels of vibration occurring at the antenna reflecting surface due to higher angular rate requirements. During image capturing it is important to keep high surface accuracy of the reflector for the quality of images. In this research, a performance degradation of deployable SAR antenna due to structural deformation is analyzed. Panels for main reflectors are assumed to be flexible structures and multi-body simulation environment is established. Then, deflection of the panel is calculated while the satellite performs maneuvers. In addition, antenna gain and beam pointing error are analyzed to determine how these deflections affect antenna performance and mission.

A Level-set Parameterization for Any 3D Complex Interface Related to a Fire Spread in Building Structures (복잡한 CAD 형상의 매개변수화를 통한 3차원 경계면 레벨-셋 알고리즘 개발 및 적용)

  • Kim, Hyun-Jun;Cho, Soo-Yeong;Lee, Young-hun;Yoh, Jai-ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.2
    • /
    • pp.135-146
    • /
    • 2020
  • To define an interface in a conventional level-set method, an analytical function must be revealed for an interfacial geometry. However, it is not always possible to define a functional form of level sets when interfaces become complex in a Cartesian coordinate system. To overcome this difficulty, we have developed a new level-set formalism that discriminates the interior from the exterior of a CAD modeled interface by parameterizing the stereolithography (STL) file format. The work outlined here confirms the accuracy and scalability of the hydrodynamic reactive solver that utilizes the new level set concept through a series of tests. In particular, the complex interaction between shock and geometrical confinements towards deflagration-to-detonation transition is numerically investigated. Also, a process of flame spreading and damages caused by point source detonation in a real-sized plant facility have been simulated to confirm the validity of the new method built for reactive hydrodynamic simulation in any complex three-dimensional geometries.

An Experimental Study on Compensation Algorithm for Localization using Modified Bilateration Technique and Pyroelectric Sensor in a Ship (변형 이변측위기법과 초전센서를 이용한 선내 위치인식 보정 알고리즘에 관한 실험적 연구)

  • Seong, Ju-Hyeon;Choi, Jae-Hyuk;Kim, Jong-Su;Seo, Dong-Hoan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.488-495
    • /
    • 2012
  • The real-time indoor location technology using radio waves has been studied in a variety of environments. One of them, a ship which consists of steel structure has high reception rate but causes significant ranging error due to the reflection of radio waves. In order to reduce location measurement errors that occurs in such a environment, this paper, based on CSS of IEEE 802.15.4a, presents compensation algorithm for localization using modified bilateration and pyroelectric sensor in a ship. The proposed system reduces the number of fixed nodes by estimating the appropriate reception distance between mobile node and fixed node through the analysis of CSS characteristic in a narrow passage such as ship corridors. Also, in the corner section which the ranging errors are significantly fluctuated due to the reflection and diffraction of radio waves, we recognize the location by tracking the a moving section using modified bilateration technique and pyroelectric sensor. The experimental results show that the location accuracy and efficiency of the proposed algorithm are improved 86.2 % compared to general method.

Study on evaluating the significance of 3D nuclear texture features for diagnosis of cervical cancer (자궁경부암 진단을 위한 3차원 세포핵 질감 특성값 유의성 평가에 관한 연구)

  • Choi, Hyun-Ju;Kim, Tae-Yun;Malm, Patrik;Bengtsson, Ewert;Choi, Heung-Kook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.10
    • /
    • pp.83-92
    • /
    • 2011
  • The aim of this study is to evaluate whether 3D nuclear chromatin texture features are significant in recognizing the progression of cervical cancer. In particular, we assessed that our method could detect subtle differences in the chromatin pattern of seemingly normal cells on specimens with malignancy. We extracted nuclear texture features based on 3D GLCM(Gray Level Co occurrence Matrix) and 3D Wavelet transform from 100 cell volume data for each group (Normal, LSIL and HSIL). To evaluate the feasibility of 3D chromatin texture analysis, we compared the correct classification rate for each of the classifiers using them. In addition to this, we compared the correct classification rates for the classifiers using the proposed 3D nuclear texture features and the 2D nuclear texture features which were extracted in the same way. The results showed that the classifier using the 3D nuclear texture features provided better results. This means our method could improve the accuracy and reproducibility of quantification of cervical cell.

Analytical Method Development of Avicularin and Quercitrin in Astilbe chinensis Extract Using HPLC (HPLC를 이용한 노루오줌 추출물의 Avicularin 및 Quercitrin 분석법 개발)

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Shin, Hyun Tak;Jung, Su Young;Choi, Jeong June;Kim, Jin Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.4
    • /
    • pp.333-340
    • /
    • 2019
  • This study attempted to eatablish a high performance liquid chromatography (HPLC) analysis method for the determination of avicularin, quercitrin as a part of the quality control for the development of functional cosmetic materials from Astilbe chinensis extract. HPLC was performed on a Capcell Pak C18 MGII column with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and acetonitrile at a flow rate of 1.0 mL/min at 30 ℃. The analyte was detected at 254 nm. The HPLC method was performed in accordance with the international conference on harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation of avicularin and quercitrin were 0.094 and 0.285 mg/mL, 0.031 and 0.095 mg/mL respectively. Calibration curves showed good linearity r2 > 0.99990 for avicularin and r2 > 0.99994 for quercitrin. Precision of analysis was satisfied with less than 0.59% for avicularin and 0.63% for quercitrin. Recoveries of quantified compounds ranged from 100.97 to 101.77% for avicularin and 100.18 to 100.32% for quercitrin. These result indicated that the established HPLC method is very useful for the determination of marker compounds in A. chinensis extracts.

Nodal Outcomes of Uniportal versus Multiportal Video-Assisted Thoracoscopic Surgery for Clinical Stage I Lung Cancer

  • Choi, Jung Suk;Lee, Jiyun;Moon, Young Kyu;Moon, Seok Whan;Park, Jae Kil;Moon, Mi Hyoung
    • Journal of Chest Surgery
    • /
    • v.53 no.3
    • /
    • pp.104-113
    • /
    • 2020
  • Background: Accurate intraoperative assessment of mediastinal lymph nodes is a critical aspect of lung cancer surgery. The efficacy and potential for upstaging implicit in these dissections must therefore be revisited in the current era of uniportal video-assisted thoracoscopic surgery (VATS). Methods: A retrospective study was conducted in which 544 patients with stage I (T1abc-T2a, N0, M0) primary lung cancer were analyzed. To assess risk factors for nodal upstaging and to limit any imbalance imposed by surgical choices, we constructed an inverse probability of treatment-weighted (IPTW) logistic regression model (in addition to non-weighted logistic models). We also evaluated risk factors for early locoregional recurrence using IPTW logistic regression analysis. Results: In the comparison of uniportal and multiportal VATS, the resected lymph node count (14.03±8.02 vs. 14.41±7.41, respectively; p=0.48) and rate of nodal upstaging (6.5% vs. 8.7%, respectively; p=0.51) appeared similar. Predictors of nodal upstaging included tumor size (odds ratio [OR], 1.74; 95% confidence interval [CI], 1.12-2.70), carcinoembryonic antigen level (OR, 1.11; 95% CI, 1.04-1.18), and histologically confirmed pleural invasion (OR, 3.97; 95% CI, 1.89-8.34). The risk factors for locoregional recurrence within 1 year were found to be number of resected N2 nodes, age, and nodal upstaging. Conclusion: Uniportal and multiportal VATS appear similar with regard to accuracy and thoroughness, showing no significant difference in the extent of nodal dissection.

Predictive mathematical model for the growth kinetics of Listeria monocytogenes on smoked salmon (온도와 시간을 주요 변수로한 훈제연어에서의 Listeria monocytogenes 성장예측모델)

  • Cho, Joon-Il;Lee, Soon-Ho;Lim, Ji-Su;Kwak, Hyo-Sun;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.120-124
    • /
    • 2011
  • Predictive mathematical models were developed for predicting the kinetics of growth of Listeria monocytogenes in smoked salmon, which is the popular ready-to-eat foods in the world, as a function of temperature (4, 10, 20 and $30^{\circ}C$). At these storage temperature, the primary growth curve fit well ($r^2$=0.989~0.996) to a Gompertz equation to obtain specific growth rate (SGR) and lag time (LT). The Polynomial model for natural logarithm transformation of the SGR and LT as a function of temperature was obtained by nonlinear regression (Prism, version 4.0, GraphPad Software). Results indicate L. monocytogenes growth was affected by temperature mainly, and SGR model equation is $365.3-31.94^*Temperature+0.6661^*Temperature^{\wedge^2}$ and LT model equation is $0.1162-0.01674^*Temperature+0.0009303^*Temperature{\wedge^2}$. As storage temperature decreased $30^{\circ}C$ to $4^{\circ}C$, SGR decreased and LT increased respectively. Polynomial model was identified as appropriate secondary model for SGR and LT on the basis of most statistical indices such as bias factor (1.01 by SGR, 1.55 by LT) and accuracy factor (1.03 by SGR, 1.58 by LT).