Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.7
/
pp.622-629
/
2019
Recently, the government is taking new approaches to change the fact that the accident rate and accident death rate of the construction industry account for a high percentage of the whole industry. Especially, it is investing heavily in the development of construction technology that is fused with ICT technology in line with the current trend of the 4th Industrial Revolution. In order to cope with this situation, this paper proposed a concept to recognize and share the work situation information between the construction machine driver and the surrounding worker to enhance the safety in the place where construction machines are operated. In order to realize the part of the concept, we applied image processing technology using camera based on artificial intelligence to earth-moving work. Especially, we implemented an algorithm that can recognize the surrounding worker's circumstance and identify the risk situation through the experiment using the compaction equipment. and image processing algorithm based on YOLO-v3. This algorithm processes 15.06 frames per second in video and can recognize danger situation around construction machine with accuracy of 90.48%. We will contribute to the prevention of safety accidents at the construction site by utilizing this technology in the future.
Choi, Hong Min;Kim, Hyo Young;Kim, Se Gun;Han, Sang Mi
Journal of Life Science
/
v.31
no.2
/
pp.144-148
/
2021
This study aimed to analyze the content and composition of a biological amine, cadaverine, isolated from the venom of worker honeybees (Apis mellifera L.). This biological amine―which has diverse functionality, such as anti-inflammatory and antibacterial effects―has not been previously reported in bee venom. An assay completed in 13 minutes was developed for the cadaverine present in the bee venom using an ultra-performance liquid chromatograph and a Halo C18 column with acetonitrile and water as the mobile phase. The specificity, accuracy, and precision of the assay were verified, and the assay was validated. The linearity for cadaverine in the bee venom was R2=0.99 or above, indicating a moderate level. The limit of detection and limit of quantification were both 0.3 ㎍/ml, and the rate of recovery was 97.6%-99.1%. The relative standard deviation (RSD) of the intra-day precision and inter-day precision for cadaverine was 0.25%-0.44% and 0.25%-1.25%, respectively, with an RSD that fell within 5% indicating excellent precision. Through this novel assay, it was found that the mean content of cadaverine was 1.10±0.05 mg/g. Our results indicated that the linearity, limit of detection, limit of quantification, and rate of recovery of the cadaverine assay were of a satisfactory level, and the cadaverine content of the bee venom was ably determined. This study provides basic data on cadaverine in bee venom, which will prove useful in further studies on the bioactivity of this component.
It is necessary to quickly detect and respond to ship accidents that occur continuously due to the influence of the recently increased maritime traffic. For this purpose, ship detection research is being actively conducted based on satellite images that can be monitored in real time over a wide area. However, there is a possibility that the wake may be falsely detected as a ship because the wake removal is not performed in previous studies that performed ship detection using spectral characteristics. Therefore, in this study, ship detection was performed using SDI (Ship Detection Index) based on the Sentinel-2A satellite image, and the wake was removed by utilizing the difference in the spectral characteristics of the ship and the wake. Probability of detection (POD) and false alarm rate (FAR) indices were used to verify the accuracy of the ship detection algorithm in this study. As a result of the verification, POD was similar and FAR was improved by 6.4% compared to the result of applying only SDI.
The Journal of The Korea Institute of Intelligent Transport Systems
/
v.19
no.6
/
pp.208-221
/
2020
The objective of this study is to estimate and analyze the traffic density of continuous flow using the trajectory of individual vehicles and the headway of sample probe vehicles-front vehicles obtained from ADAS (Advanced Driver Assitance System) installed in sample probe vehicles. In the past, traffic density of continuous traffic flow was mainly estimated by processing data such as traffic volume, speed, and share collected from Vehicle Detection System, or by counting the number of vehicles directly using video information such as CCTV. This method showed the limitation of spatial limitations in estimating traffic density, and low reliability of estimation in the event of traffic congestion. To overcome the limitations of prior research, In this study, individual vehicle trajectory data and vehicle headway information collected from ADAS are used to detect the space on the road and to estimate the spatiotemporal traffic density using the Generalized Density formula. As a result, an analysis of the accuracy of the traffic density estimates according to the sampling rate of ADAS vehicles showed that the expected sampling rate of 30% was approximately 90% consistent with the actual traffic density. This study contribute to efficient traffic operation management by estimating reliable traffic density in road situations where ADAS and autonomous vehicles are mixed.
In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.
Kwon, Jin Gwan;Seo, Changon;Jung, Yeon Woo;Choi, Yongmun;Shin, Hyun Tak;Jung, Su Young;Choi, Jeong June;Kim, Jin Kyu
Journal of the Society of Cosmetic Scientists of Korea
/
v.47
no.1
/
pp.57-63
/
2021
In this study, isoscoparin was selected as an indicator component to develop Silene seoulensis extract as a functional cosmetic material, and we developed an analysis method using high performance liquid chromatography (HPLC) for quality control. HPLC was performed on a Unison US-C18 with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methanol at a flow rate of 1.0 mL/min at 35 ℃, and the detection wavelength was 330 nm. The HPLC method was performed in accordance with the international conference on harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.02 and 0.07 mg/mL respectively. Calibration curves showed good linearity (R2 > 0.99988), and the precision of analysis was satisfied (less than 0.46%). In addition, the recovery rate was in the range of 99.10 to 101.61%, it was shown to be accurate. This result indicated that the established HPLC method is very useful for the determination of marker compounds in Silene seoulensis extracts.
DLG (Dosimetric Leaf Gap) and transmission factor are important parameters of MLC modeling in treatment planning system. In this study, DLG and transmission factor of HD-MLC were measured using detector with different measuring volumes, and the accuracy of the treatment plans was evaluated according to the DLG values. DLG was measured using the dynamic sweeping gap method with Semiflux3D and MicroDiamond detectors. Then, 10 radiation treatment plans were generated to optimize the DLG value and compared with the measurement results. Photon energies 6, 8, 10 MV, the DLG measured by Semiflux3D were 0.76, 0.83, and 0.85 mm, and DLG measured by MicroDiamond were 0.78, 0.86, and 0.9 mm. All plans were measured by portal dosimetry and analyzed using Gamma Evaluation. In the 6 MV photon beams, the average gamma passing rate were 94.3% and 98.4% for DLG 0.78 mm and 1.15 mm. In the 10 MV photon beam, the average gamma passing rate were 91.2% and 97.6% for DLG 0.9 mm and 1.25 mm. HD-MLC needs accurate modeling in the treatment planning system. DLG could be used measured data using small volume detector. However, for better radiation therapy, DLG should be optimized at the commissioning stage of LINAC.
Kim, Eunchong;Sodirzhon-Ugli, Nodirbek Yuldashev;Kim, Do Wan;Lee, Kyo Seon;Lim, Yonghwan;Kim, Min-Chul;Cho, Yong Soo;Jung, Yong Hun;Jeung, Kyung Woon;Cho, Hwa Jin;Jeong, In Seok
Journal of Chest Surgery
/
v.55
no.2
/
pp.143-150
/
2022
Background: The effectiveness of extracorporeal membrane oxygenation (ECMO) for patients with refractory cardiogenic shock or cardiac arrest is being established, and serum lactate is well known as a biomarker of end-organ perfusion. We evaluated the efficacy of pre-ECMO lactate for predicting 6-month survival in patients with acute coronary syndrome (ACS) undergoing ECMO. Methods: We reviewed the medical records of 148 patients who underwent veno-arterial (VA) ECMO for ACS between January 2015 and June 2020. These patients were divided into survivors and non-survivors based on 6-month survival. All clinical data before and during ECMO were compared between the 2 groups. Results: Patients' mean age was 66.0±10.5 years, and 116 (78.4%) were men. The total survival rate was 45.9% (n=68). Cox regression analysis showed that the pre-ECMO lactate level was an independent predictor of 6-month mortality (hazard ratio, 1.210; 95% confidence interval [CI], 1.064-1.376; p=0.004). The area under the receiver operating characteristic curve of pre-ECMO lactate was 0.64 (95% CI, 0.56-0.72; p=0.002; cut-off value=9.8 mmol/L). Kaplan-Meier survival analysis showed that the cumulative survival rate at 6 months was significantly higher among patients with a pre-ECMO lactate level of 9.8 mmol/L or less than among those with a level exceeding 9.8 mmol/L (57.3% vs. 31.8%, p=0.0008). Conclusion: A pre-ECMO lactate of 9.8 mmol/L or less may predict a favorable outcome at 6 months in ACS patients undergoing VA-ECMO. Further research aiming to improve the accuracy of predictions of reversibility in patients with high pre-ECMO lactate levels is essential.
Hye Inn Song;Hwa Jeong Tak;Kang Won Shin;Sang Hoon Son
The Journal of The Korea Institute of Intelligent Transport Systems
/
v.22
no.3
/
pp.131-146
/
2023
Smart card data is widely used in the public transportation field. Despite the inevitability of various errors occur during the data collection and storage; however, smart card data errors have not been extensively studied. This paper investigates inherent errors in boarding and alighting station information in smart card data. A comparison smart card data and bus boarding and alighting survey data for the same time frame shows that boarding station names differ by 6.2% between the two data sets. This indicates that the error rate of smart card data is 6.2% in terms of boarding station information, given that bus boarding and alighting survey data can be considered as ground truth. This paper propose 6-step algorithm for correcting errors in smart card boarding station information, linking them to corresponding information in Bus Information System(BIS) Data. Comparing BIS data and bus boarding and alighting survey data for the same time frame reveals that boarding station names correspond by 98.3% between the two data sets, indicating that BIS data can be used as reliable reference for ground truth. To evaluate its performance, applying the 6-step algorithm proposed in this paper to smart card data set shows that the error rate of boarding station information is reduced from 6.2% to 1.0%, resulting in a 5.2%p improvement in the accuracy of smart card data. It is expected that the proposed algorithm will enhance the process of adjusting bus routes and making decisions related to public transportation infrastructure investments.
Donggil Seo;Kyung Hyun Ahn;Jihoon Kang;Sangsoo Park
The Journal of the Convergence on Culture Technology
/
v.9
no.4
/
pp.331-335
/
2023
As the viscosity of the blood increases, the blood becomes more sticky and difficult to flow, so the possibility of thrombosis increases and the probability of ischemic cerebral infarction increases. The importance of measuring blood viscosity has recently been emphasized for the prevention of circulatory system diseases, and the need for a viscometer capable of easily and accurately measuring blood viscosity has emerged. In this study, the measured values of a viscosity standard solution and an artificial blood by a parallel-plate viscometer ARS-Medi were compared with the those by Ares-G2 of TA instrument, which is internationally recognized for its accuracy and reliability. The viscosity of N44 standard solution, which is a Newtonian solution, was almost perfectly matched between the two instruments at all shear rates. In the case of an artificial blood, which is a non-Newtonian solution, the measured values between the two instruments showed a difference of about 10% at the lowest shear rate 1 rad/s; however, at a clinically significant shear rate of 10 rad/s or higher, the measured values between them were consistent within the error range. We expect that ARS-Medi, a newly developed parallel-plate viscometer for blood, using disposable plates, will be very useful in clinical practice as it improves the convenience and hygiene of blood viscosity measurement.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.