• Title/Summary/Keyword: Accuracy Assessment

Search Result 1,578, Processing Time 0.032 seconds

Perceptions of Quality Nursing care of Patients and Families (질적 간호에 대한 환자와 가족의 지각)

  • Chi, Sung-Ai;Kwon, Sung-Bok;Park, Eun-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.1
    • /
    • pp.247-275
    • /
    • 1998
  • The purpose of this study was to offer the results of content analysis and qualitative study that explored the perceptions about quality nursing care of patients and families as consumers and to identify the implications of this study for quality nursing care management and research. The data was collected from 12 adult patients and 9 families who were admmitted at medical and surgical nursing unit of one university hospital in Seoul from October, 1996 to January, 1997. Research participants were asked to response "what do you think quality nursing care?" and similar questions during the interviews was performed. Data were analyzed using open coding and content analysis with frequencies and percents of attributes of quality nursing care. Attributes of quality nursing care and meaning of quality nursing care that patients and families perceived were explored. 1. The attributes of quality nursing care that patient and families perceived were categorized into 56 attributes. The highest response rate among the attributes was 'one's heart at ease' (76.2%), and the next high response rates were ranked in order 'consideration' , 'care about' (each 61.9% 'expert skill' (57.1%), 'deal with problem promptly' , 'information offer' (42.9%), 'intimate feeling' (38.1%), 'smile' 'service spirit' , 'do one's best' (each 33.3%), 'frequent visit' (23.8%), 'observe the time' (23.8%), 'direct nursing care' , 'speaking warmly' , give a hope' , 'address kindly' , 'a sense of duty' , 'good facilities' (each 19.0%), 'inquire after a patient health' , 'patient-centered nursing care' , 'showing an example' , 'professional knowledge' , 'careless moraly patient' , 'give encourage to patients' , 'good answer a question' (each 14.3%), 'do not imprudently' , 'do not disregard' , 'broad knowledge' , 'emergency treatment skill' , 'dependability' ,'consolation' giving a sense of security' , 'a self sacrificing spirit' , 'a sense of responsibility' 'hard - working', 'enough disposition of nursing staff (each 9.5%), 'improve patient's pride' and the rest attributes exhibited 4.7%, respectively. 2. The attributes that were identified in patients' data only were 8 categories, 'service sprit' (58.3 %) 'expert knowledge' , 'good answer a question' (each 25.0%), 'hard working' (16.7%), 'a warm character', 'professional attainments', 'do without reserve', 'satisfaction' (each 8.3%), 3. The attributes were identified to families' data only were 31 categories, 'speaking warmly' , 'direct nursing care', 'adress kindly', 'patientcentered nursing care', 'showing an example' (each 33.3%). 'do not imprudently' , 'do not disregard' , 'consolation', 'giving a sense of security', 'broad knowledge' , 'emergency treatment skill', 'dependability' ,'a self - sacrificing spirit', 'a sense of responsibility' (each 22.2%), 'improve patient's pride' , 'without discrimination' , 'show kindness' , 'individual nursing care', 'being with patient' , 'helping' , 'accuracy' , 'without any mistake' , 'love' , 'self - confidence', 'self possession', 'a self - denying spirit' , 'a sense of duty' , 'tighten discipline' , 'disposed room with similar patient to diagnosis', 'compensatory relationship between me dical team' , 'role of connection' (each 11.1 %). 4. The attributes of quality nursing care were integrated into 11 categories that they were 'patientcentered nursing care' (25.1%), 'expertise' (22.1%), 'caring'(18.1%), 'kindness'(11.1%L 'nurse attainments(10.1%), 'sincerity' (7.5%), 'good environment' (2.0%), 'effective organizational management', 'coordination', 'enough nursing staff' ( each 1.0%), 'satisfaction' (0.5%) were showed in the order of the highest rate. 5. The concept of quality nursing care were defined as 'give a satisfaction to patients by patientcentered care based on professional skill and caring with kindness and sincerity'. The description of the meaning of quality nursing care provided by this research participants, patients and families can provide important information for quality nursing care management, medical marketing, education and researches of this field. On the basis of the above findings the following recommendations are made: to suggest to utilize this results for patient care in practice setting, development of quality assessment tool in nursing care, repeat study by the same subjects and method, and to a comparative study by the same method to nurse.

  • PDF

Applicability of UAV in Urban Thermal Environment Analysis (도시 내 열환경 분석에서 무인항공기의 활용가능성)

  • Kang, Da-In;Moon, Ho-Gyeong;Sung, Sun-Yong;Cha, Jae-Gyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.52-61
    • /
    • 2018
  • Urban heat islands occur due to increases in the extent of artificial surfaces such as concrete, asphalt and high-rise buildings. In this regard, research into the use of satellite thermal infrared images for thermal environment analysis of urban areas is being carried out. However, such analysis of the characteristics of individual land cover with low-resolution satellite images suffers from limitations because land cover patterns in urban areas are complicated. Recently, UAV has been widely used, which can compensate for this limitation as it is able to acquire high-resolution images. In this paper, the accuracy of UAV infrared images is verified and the applicability of UAV in urban thermal environment analysis is examined by comparing the results with land surface temperatures from Landsat 8 thermal images. The results show a high positive correlation of temperature values at 0.95, and no statistically significant difference between the two groups. Comparisons of land surface temperature according to land cover showed that the largest difference observed was $4.63^{\circ}C$ in the Used area, and UAV images with small cell units reflected various surface temperatures. Furthermore, it was possible to analyze the surface temperatures of various green spaces such as wetlands and street tree areas, which can lower surface temperatures in urban areas, with street tree shadows reducing surface temperatures by about $4-6^{\circ}C$. UAV can easily and rapidly measure the surface temperature of urban areas and is able to analyze various types of green spaces. Thus, this is an effective tool for thermal environment analysis in urban areas to aid in the design or management of urban green spaces, as it can allow for land cover and the effects of the various green spaces.

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

The Effects of Cognitive Bias on Entrepreneurial Opportunity Evaluations through Perceived Risks in Entrepreneurial Self-Efficacy (창업가의 인지편향이 지각된 위험과 조절된 창업효능감에 따라 창업기회평가에 미치는 영향)

  • Kim, Daeyop;Park, Jaehwan
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.1
    • /
    • pp.95-112
    • /
    • 2020
  • This paper is to investigate how cognitive bias of college students and entrepreneurs relates to perceived risks and entrepreneurial opportunities that represent uncertainty, and how various cognitive bias and entrepreneurial efficacy In the same way. The purpose of this study is to find improvement points of entrepreneurship education for college students and to suggest problems and improvement possibilities in the decision making process of current entrepreneurs. This empirical study is a necessary to improve the decision-making of individuals who want to start a business at the time when various attempts are made to activate the start-up business and increase the sustainability of the existing SME management. And understanding of the difference in opportunity evaluation, and suggests that it is necessary to provide good opportunities together with the upbringing of entrepreneurs. In order to achieve the purpose of the study, questionnaires were conducted for college students and entrepreneurs. A total of 363 questionnaire data were obtained and demonstrated through structural equation modeling. This study confirms that there is some relationship between perceived risk and cognitive bias. Overconfidence and control illusions among cognitive bias have a significant relationship between perceived risk and wealth. Especially, it is confirmed that control illusion of college students has a significant relationship with perceived risk. Second, cognitive bias demonstrated some significant relationship with opportunity evaluation. Although we did not find evidence that excess self-confidence is related to opportunity evaluation, we have verified that control illusions and current status bias are related to opportunity evaluation. Control illusions were significant in both college students and entrepreneurs. Third, perceived risk has a negative relationship with opportunity evaluation. All students, regardless of whether they are college students or entrepreneurs, judge opportunities positively if they perceive low risk. Fourth, it can be seen from the college students 'group that entrepreneurial efficacy has a moderating effect between perceived risk and opportunity evaluation, but no significant results were found in the entrepreneurs' group. Fifth, the college students and entrepreneurs have different cognitive bias, and they have proved that there is a different relationship between entrepreneurial opportunity evaluation and perceived risk. On the whole, there are various cognitive biases that are caused by time pressure or stress on college students and entrepreneurs who have to make judgments in uncertain opportunities, and in this respect, they can improve their judgment in the future. At the same time, university students can have a positive view of new opportunities based on high entrepreneurial efficacy, but if they fully understand the intrinsic risks of entrepreneurship through entrepreneurial education and fully understand the cognitive bias present in direct entrepreneurial experience, You will get a better opportunity assessment. This study has limitations in that it is based on the fact that university students and entrepreneurs are integrated, and that the survey respondents are selected by the limited random sampling method. It is necessary to conduct more systematic research based on more faithful data in the absence of the accumulation of entrepreneurial research data. Second, the translation tools used in the previous studies were translated and the meaning of the measurement tools might not be conveyed due to language differences. Therefore, it is necessary to construct a more precise scale for the accuracy of the study. Finally, complementary research should be done to identify what competitive opportunities are and what opportunities are appropriate for entrepreneurs.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images (PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가)

  • Han, Dong Chan;Hong, Gun Chul;Choi, Choon ki;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of $^{18}F-FDG$. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.67{\pm}0.06g/mL$ and $0.65{\pm}0.06g/mL$, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.32{\pm}0.08g/mL$ and $0.56{\pm}0.12g/mL$, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Assessment of the Specificity of A Hybridization of Surfactant Protein A by Addition of Non-specific Rat Spleen RNA (Surfactant Protein A mRNA을 이용한 유전자 재결합 반응에서 비특이성 RNA의 첨가에 의한 특이성 검정)

  • Kim, Byeong Cheol;Kim, Mi Ok;Kim, Tae-Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.393-404
    • /
    • 2004
  • Background : Nucleic acid hybridization has become an essential technique in the development of our understanding of gene structure and function. The quantitative analysis of hybridization has been used in the measurement of genome complexity and gene copy number. The filter hybridization assay is rapid, sensitive and can be used to measure RNAs complementary to any cloned DNA sequence. Methods : The authors assessed the accuracy, linearity, correlation coefficient and specificity of the hybridization depending on the added dose(0, 1, 5, and $10{\mu}g$) of non-specific rat spleen RNA to hybridization of surfactant protein A mRNA. Filter hybridization assays were used to obtain the equation of standard curve and thereby to quantitate the mRNA quantitation. Results : 1. Standard curve equation of filter hybridization assay between counts per minute (X) and spleen RNA input (Y) was Y=0.13X-19.35. Correlation coefficient was 0.98. 2. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) was Y=0.00066X-0.046. Correlation coefficient was 0.99. 3. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $1{\mu}g$ spleen RNA was Y=0.00056X-0.051. Correlation coefficient was 0.99. 4. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $5{\mu}g$ spleen RNA was Y=0.00065X-0.088. Correlation coefficient was 0.99. 5. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $10{\mu}g$ spleen RNA was Y=0.00051X-0.10. Correlation coefficient was 0.99. Conclusions : Comparison of cpm/filter in a linear range allowed accurate and reproducible estimation of surfactant protein A mRNA copy number irrespective of the addition dosage of non-specific rat spleen RNA over the range $0-10{\mu}g$.

Assessment of the Angstrom-Prescott Coefficients for Estimation of Solar Radiation in Korea (국내 일사량 추정을 위한 Angstrom-Prescott계수의 평가)

  • Hyun, Shinwoo;Kim, Kwang Soo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.221-232
    • /
    • 2016
  • Models to estimate solar radiation have been used because solar radiation is measured at a smaller number of weather stations than other variables including temperature and rainfall. For example, solar radiation has been estimated using the Angstrom-Prescott (AP) model that depends on two coefficients obtained empirically at a specific site ($AP_{Choi}$) or for a climate zone ($AP_{Frere}$). The objective of this study was to identify the coefficients of the AP model for reliable estimation of solar radiation under a wide range of spatial and temporal conditions. A global optimization was performed for a range of AP coefficients to identify the values of $AP_{max}$ that resulted in the greatest degree of agreement at each of 20 sites for a given month during 30 years. The degree of agreement was assessed using the value of Concordance Correlation Coefficient (CCC). When $AP_{Frere}$ was used to estimate solar radiation, the values of CCC were relatively high for conditions under which crop growth simulation would be performed, e.g., at rural sites during summer. The statistics for $AP_{Frere}$ were greater than those for $AP_{Choi}$ although $AP_{Frere}$ had the smaller statistics than $AP_{max}$ did. The variation of CCC values was small over a wide range of AP coefficients when those statistics were summarized by site. $AP_{Frere}$ was included in each range of AP coefficients that resulted in reasonable accuracy of solar radiation estimates by site, year, and month. These results suggested that $AP_{Frere}$ would be useful to provide estimates of solar radiation as an input to crop models in Korea. Further studies would be merited to examine feasibility of using $AP_{Frere}$ to obtain gridded estimates of solar radiation at a high spatial resolution under a complex terrain in Korea.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.