• Title/Summary/Keyword: Accumulated temperature

Search Result 553, Processing Time 0.028 seconds

A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine (드럼세탁기 화재안전성 확보를 위한 실험연구)

  • Hong, Sung-Ho;Lee, Sang-Hyun;Park, Sang-Tae;Yu, Hyun-Jong;Jeon, Woong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가)

  • 임중관;박용필;김정호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

An Analysis of Insulating Reliability in Epoxy Composites for Molding Materials of PT

  • Yang, Jeong-Yun;Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.43-46
    • /
    • 2001
  • The DC dielectric breakdown of epoxy composites used for transformer was experimented and then its data were simulated by Weibull distribution equation in this study. The more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical, and the breakdown strength of specimens with filler was lower than it of non-filler specimens because it was believed that the adding filler formed interface, charges were accumulated in it, the molecular mobility was raised, the electric field was concentrated, electrons were accelerated and then electron avalanche was early accomplished. From the analysis of Wei bull distribution equation, it was confirmed that as the allowed breakdown probability was· given by 0.1[%], the value of 'applied field was needed to be under 17.20[kV/mm].

  • PDF

아질산성 질소의 축적에 대한 용존 산소와 free ammonia의 영향 연구

  • Han, Dong-U;Lee, Su-Cheol;Lee, Nam-Hui;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.475-478
    • /
    • 2000
  • For an integrated nitrification-denitrification process, nitrite formation in the aerobic stage leads to big savings. Dissolved oxygen concentration, temperature, pH and free ammonia concentration have been meet for nitrite accumulation. Also their effects over the ammonia oxidizers and nitrite oxidizers have been studied. Dissolved oxygen limitation and free ammonia inhibition led to slow nitrification and nitrite build up. In this study batch kinetics of ammonium and nitrite oxidations were performed with free ammonia accumulated nitrifiers. From the results it is likely the nitrite oxidizers are inhibited by oxygen limitation rather than free ammonia.

  • PDF

Analysis of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 분석)

  • 최철호;박용필;임중관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.414-419
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of (idled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites

  • Park, No-Bong;Yang, Dong-Bok;Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab;Kim, Gui-Yeul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1200-1203
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1% level requires the allowable field allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF

Experimental Test Numerical Simulation of SMA Characteristics and Device verification (형상기억합금 수치해석을 위한 특성 실험 및 작동기 응용)

  • Kim, Sang-Haun;Choi, Hyun-Ho;Cho, Maeng-Hyo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.145-148
    • /
    • 2005
  • In this study, adaptation of two-way shape memory effect of SMA wire to the actuator is examined . Therefore the SMA characteristics which are training, material properties, response time at different thermal cycling rates are tested. During training, permanent deformation is accumulated till a certain number of cycle and then saturated. The amow1t of two-way strain is unchangeable over all cycle and the slope of strain(or stress)-temperature curve is slower as the increase of applied stress. The rate effect is observed resulted from the thermal distribution which heating profile differs from cooling as thermal cycling time. Using the estimated SMA properties, an experimental test for the simple smart wing is performed.

  • PDF

A Study on Damage-Assessment of RC Large Cooling Tower Shells (RC 대형 냉각탑 셀의 손상추정에 관한 연구)

  • Noh, Sam-Young
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.279-286
    • /
    • 2004
  • An accumulated crack damage which propagates progressively with time was frequently observed on several engineering structures, This paper numerically demonstrates this damage process on large cooling tower shells under thermal and wind loads. Damage states under varying loads are investigated and the influence of this progressive damage process on the life-cycle of cooling towers discussed. The paper presents briefly some fundamentals of the geometrically and physically non-linear numerical analysis employed for reinforced concrete, especially concerning the models used for concrete, steel reinforcement and the bond between them. As a numerical example an existing cooling tower with noticeable meridian crack damage is analysed. The existing damage state of the cooling tower is determined by quasi-static analyses for temperature, hygric and cyclic wind leading. The change in the dynamical behaviour of the structure as mirrored in its natural frequencies and mode shapes is presented and discussed. Finally, the example shows that such damage processes develop progressively over the life-time of the structures.

  • PDF

Production of Poly-3-Hydroxyalkanhoate by Haloarcular sp. EH-1 (Haloarcular sp. EH-1으로부터 생분해성 Poly-3-Hydroxyalkanoate의 생산)

  • 정명주;박형숙
    • Journal of Life Science
    • /
    • v.9 no.6
    • /
    • pp.737-742
    • /
    • 1999
  • The extremely halophilic archaebacterium Haloarcular sp. EH-1 was isolated from solar salts. Haloarcular sp. EH-1 accumulated poly(3-hydroxyalkanoate) (PHA) as intracellular granules. PHA production in batch culture have been studied. The PHA was identified as poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) (PHB/HV) of 3-hydroxybutyric acid and 3-hydroxyvaleric acid by the analysis of GC, IR and NMR. The melting temperature of PHB/HV was 152.46$^{\circ}C$, viscosity was 1.25 ㎗/g, and molecular weight was $1.44 X 10^5.$

  • PDF

Effect of Interfacial Condition on Space Charge of PE Laminate (계면조건에 따른 PE Laminate의 전하분포)

  • Noh, Hong-S.;Kim, Ok;Lee, Mi-Kyung;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.392-394
    • /
    • 1995
  • The interfacial charge distribution was investigated using PE laminate system. It was found that a proper treatment of the interlace could decrease the amount of charge accumulated at the interfaces. High lamination temperature and long lamination time brought about little interfacial charge. It was also observed that the interfacial charge could be decreased by the addition of chemicals which had charge trap or hopping site.

  • PDF