Low-Dose Abdominal CT for Evaluating Suspected Appendicitis in Adolescents and Young Adults: Review of Evidence

  • Ji Hoon Park;Paulina Salminen;Penampai Tannaphai;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • 제23권5호
    • /
    • pp.517-528
    • /
    • 2022
  • Due to its excellent diagnostic performance, CT is the mainstay of diagnostic test in adults with suspected acute appendicitis in many countries. Although debatable, extensive epidemiological studies have suggested that CT radiation is carcinogenic, at least in children and adolescents. Setting aside the debate over the carcinogenic risk of CT radiation, the value of judicious use of CT radiation cannot be overstated for the diagnosis of appendicitis, considering that appendicitis is a very common disease, and that the vast majority of patients with suspected acute appendicitis are adolescents and young adults with average life expectancies. Given the accumulated evidence justifying the use of low-dose CT (LDCT) of only 2 mSv, there is no reasonable basis to insist on using radiation dose of multi-purpose abdominal CT for the diagnosis of appendicitis, particularly in adolescents and young adults. Published data strongly suggest that LDCT is comparable to conventional dose CT in terms of clinical outcomes and diagnostic performance. In this narrative review, we will discuss such evidence for reducing CT radiation in adolescents and young adults with suspected appendicitis.

AN INVESTIGATION INTO RADIATION LEVELS ASSOCIATED WITH DISMANTLING THE KOREA RESEARCH REACTOR

  • Choi, Geun-Sik;Kim, Hee-Reyoung;Han, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.468-473
    • /
    • 2010
  • We confirmed that the dismantling of two research reactors with thermal power of $2MW_{th}$ and $100kW_{th}$, respectively, reveals no significant difference between the radiation levels of the research reactor site and the surrounding environment far away from it, from the radiation level aspect. Radiation dose and radioactivity were measured at monitoring points around the research reactor site of the Korea Atomic Energy Research Institute (KAERI) in Seoul and comparison points 0.5 km to 3.3 km from the site. To grasp trends in the radiation levels during dismantling from the end of 2002 to the end of 2007, the gamma radiation dose rate, the accumulated dose, and the radioactivity of the strontium, tritium, and gamma isotopes were statistically treated and estimated. The averages of these items between the two groups, the research reactor site and comparison points, were assessed by applying a T-test with a significance level of 0.05. P-values found by using the T-test were from 0.12 to 0.83 where the values were much higher than the significance level. As a result, no difference was observed between the radiation levels at the research reactor site and at the comparison points by this T-test. This study showed that dismantling activity of the Korea Research Reactor of the Seoul site did not expose the public or the environment to harmful levels of radiation.

핵의학과 주사와 분배업무 작업종사자 및 수시출입자 피폭선량연구 (A Study on Exposure Dose from Injection Work and Elution Work for Radiation Workers and Frequent Workers in Nuclear Medicine)

  • 주용진;동경래;최은진;곽종길;류재광;정운관
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.47-54
    • /
    • 2017
  • Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a significant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity.

아리랑 2호의 방사능 환경 및 영향에 관한 분석(I)- TOTAL IONIZING DOSE 영향 중심으로 - (THE ANALYSIS ON SPACE RADIATION ENVIRONMENT AND EFFECT OF THE KOMPSAT-2 SPACECRAFT(I): TOTAL IONIZING DOSE EFFECT)

  • 백명진;김학정
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.153-162
    • /
    • 2001
  • 본 논문에서는 아리랑 2호가 운용될 궤도의 우주방사능 환경 및 total ionizing dose(TID) 영향에 대하여 분석하였다. 포획된 양자의 경우 SAA(South Atlantic Anomaly) 지역에 집중되어 있음을 알 수 있었으며, TID에 영향을 미치는 우주 방사능은 포획된 양자 및 전자와 태양양자임을 알 수 있었다. 저 에너지 입자는 알루미늄 차단 구조물을 이용하여 방사능 영향을 효과적으로 차단할 수 있음을 알 수 있었으나, 고 에너지 입자의 경우 구조물의 두께를 증가하여도 방사능 영향을 효과적으로 차단할 수 없음을 알 수 있었다. 아리랑 2호의 임무수명기간 동안 전자부품에 계속적으로 피폭되는 전체 방사량을 알루미늄 차단두께의 함수로 나타내었으며, 이 값들은 아리랑 2호의 전자부품의 선택기준 및 위성체 또는 구성품의 구조물 두께를 설정할 수 있는 기준으로 제시하였다.

  • PDF

방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰 (Consideration about Radiological Technology Student's Frequent Workers Exposure Dose Rate)

  • 박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.573-580
    • /
    • 2018
  • The Nuclear Safety Commission amended the Nuclear Safety Act by strengthening the safety management system for the frequent workers to the level of radiation workers. And students entering radiation management zones for testing and practical purposes are subject to frequent workers. It is inevitable that this will incur additional costs. In this paper, the validity of the amendment to the Nuclear Safety Act was to be assessed in terms of radiation protection. Study subjects are from 2014 to 2016, among university students in Seong-nam Korea and comparisons for analyses were made taking into account variables that are differences in annual, practical types, on-class and clinical practice students exposure dose. The analysis showed that exposures between on-class and clinical practice received were less than the annual dose limit of 1 mSv for the public. Then, some alternatives that excluding from frequent workers during on-class practice or mitigating the frequent workers' safety regulation for only on-class frequent workers can be considered. Optimization is how rational is the reduction in exposure dose to the costs required. Therefore, the results are hardly considered for optimization. If the data accumulated, it could be considered that the revision of the act could be evaluated and improved.

근접방사선조사에 의한 두경부암의 치료 (Brachytherapy in the Treatment of Head and Neck Cancer)

  • 류성렬
    • Radiation Oncology Journal
    • /
    • 제17권3호
    • /
    • pp.179-187
    • /
    • 1999
  • 치료선량의 증가와 주위 정상조직의 보호의 의미에서 근접치료의 효과는 입증되어 있다. 그러나 우리 나라에서는 아직 통상치료법으로 상용화가 되어 있지 않다. 저자는 저선량률 이리디움 근접조사치료의 임상적 경험을 바탕으로 두경부암에서의 근접조사치료의 역사, 사용되는 동위원소의 재원 및 특성, 시행 시 고려 하여야할 사항, 임상기술적인 문제, 방사선물리학적 문제 등을 검토하였고 저자의 임상 경험 185례의 치료성적을 분석하여 그 효과를 검증하였고 마지막으로 향후 발전방향을 제시하여 보았다.

  • PDF

영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석 (Analysis of the Imaging Dose for IGRT/Gated Treatments)

  • 신정석;한영이;주상규;신은혁;홍채선;안용찬
    • Radiation Oncology Journal
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2009
  • 목적: 영상유도방사선치료(IGRT)와 호흡동조방사선치료(4DRT)의 도입은 치료계획 및 치료부위 확인에서 환자에게 방사선 조사량을 증가시킬 가능성이 있다. 따라서 IGRT/4DRT용 영상장비와 기존 장비에서 영상선량을 측정 및 비교하였다. 대상 및 방법: IGRT 및 4DRT를 위해 새로이 도입된 4DCT (GE, Ultra Light Speed 16)와 모의치료기(Varian Acuity), 그리고 치료기(Varian IX)에 장착된 kVp (OBI)의 영상장비 및 EPID (aSi 1000)를 대상으로, RANDO 팬톰의 표면 선량을 측정하여 기존의 장비들(single slice CT (GE, Light Speed), 모의치료기(Varian, Ximatron), L-gram (Varian 2100C))과 비교하였다. 측정은 열형광선량계를 이용하여 두뇌부, 눈, 갑상선, 흉부, 복부 및 골반부의 표면에서 측정하였다. 결과: 기존 CT와 비교하여 4DCT모드에서는 흉부와 복부에서 10배 이상의 선량증가를 보였다($1.74{\pm}0.34$ vs $23.23{\pm}3.67$ cGy). Acuity에서의 선량은 모든 측정부위에서 Ximatron보다 감소하였다($0.91{\pm}0.89$ vs $6.77{\pm}3.56$ cGy). EPID는 기존 L-gram 선량의 약 50% ($1.83{\pm}0.36$ vs $3.80{\pm}1.67$ cGy)였다. OBI의 투시영상선량은 $0.97{\pm}0.34$ cGy며, CBCT 선량은 $2.3{\pm}0.67$ cGy였다. 결론: 4DCT가 선량증가의 가장 큰 원인이며, OBI와 CBCT에 의한 선량은 적으나 매번 치료에 적용 시 총 선량 증가에 대한 고려가 필요하다.

Feasibility of Shrinking Field Radiation Therapy through 18F-FDG PET/CT after 40 Gy for Stage III Non-Small Cell Lung Cancers

  • Ding, Xiu-Ping;Zhang, Jian;Li, Bao-Sheng;Li, Hong-Sheng;Wang, Zhong-Tang;Yi, Yan;Sun, Hong-Fu;Wang, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권1호
    • /
    • pp.319-323
    • /
    • 2012
  • Objective: To explore the feasibility of shrinking field technique after 40 Gy radiation through 18F-FDG PET/CT during treatment for patients with stage III non-small cell lung cancer (NSCLC). Methods: In 66 consecutive patients with local-advanced NSCLC, 18F-FDG PET/CT scanning was performed prior to treatment and repeated after 40 Gy. Conventionally fractionated IMRT or CRT plans to a median total dose of 66Gy (range, 60-78Gy) were generated. The target volumes were delineated in composite images of CT and PET. Plan 1 was designed for 40 Gy to the initial planning target volume (PTV) with a subsequent 20-28 Gy-boost to the shrunken PTV. Plan 2 was delivering the same dose to the initial PTV without shrinking field. Accumulated doses of normal tissues were calculated using deformable image registration during the treatment course. Results: The median GTV and PTV reduction were 35% and 30% after 40 Gy treatment. Target volume reduction was correlated with chemotherapy and sex. In plan 2, delivering the same dose to the initial PTV could have only been achieved in 10 (15.2%) patients. Significant differences (p<0.05) were observed regarding doses to the lung, spinal cord, esophagus and heart. Conclusions: Radiotherapy adaptive to tumor shrinkage determined by repeated 18F-FDG PET/CT after 40 Gy during treatment course might be feasible to spare more normal tissues, and has the potential to allow dose escalation and increased local control.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

C 대학병원의 개인선량계 판독과 영향 (Reading and Influence of Personal Dose Meter in University Hospital C)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.357-363
    • /
    • 2022
  • 본 연구 목적은 방사선관계종사자와 방사선작업종사자들의 직종별 방사선 피폭선량을 분석하여 폐 부작용 유발확률을 연구하는 데에 있다. 즉, 피폭관리 실태를 점검함으로써 방사선종사자들의 직업상 피폭에 대한 안전 점검 의식을 향상시키고 방사선안전관리에 도움을 주고자 한다. 방사선관계종사자와 방사선작업종사자 각각 3개의 직종별 (방사선사, 의사, 간호사)로 분류하였다. 피폭선량으로 인한 폐의 부작용 유발확률을 산출하기 위하여 ICRP103에 근거한 명목위험계수(Nominal risk factor)를 활용하였다. 방사선관계종사자의 1년간 심부선량은 방사선사 1.63 ± 2.84 mSv, 의사는 0.12 ± 0.22 mSv, 간호사는 0.59 ± 1.08 mSv로 나타났다. 이로 인하여, 폐의 부작용 유발 확률은 방사선사는 100,000당 1.1명, 의사는 10.082명, 간호사는 0.4명으로 나타났다. 방사선작업종사자의 1년간 심부선량은 방사선사 2.44 ± 3.30 mSv, 의사의 경우 0.19 ± 0.26 mSv, 간호사의 경우 0.12 ± 0.00 mSv이었다. 이 선량으로 인하여, 폐의 부작용 유발 확률은 방사선사는 100,000당 1.2명, 의사는 0.096명, 간호사는 0.06명으로 나타났다. 본 연구에서는 방사선 피폭선량의 직종별 폐에 부작용이 발생할 확률을 연구하여 향후 확률적 영향과 관련하여 방사선 안전관리를 위하여 유용한 자료로 활용될 것으로 사료된다.