• Title/Summary/Keyword: Accumulated distribution

Search Result 431, Processing Time 0.032 seconds

Study on the Accumulative Distribution of Malation and itns Determination form the Human Tissue. (사체중 MaIathion의 각 장기조직별 분석 및 정량에 관한 연구)

  • 이완구;박성우
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.18-20
    • /
    • 1978
  • An experimental study was conducted to determine the quantity of contamination of organophosphrous pesticides accumulated in each human tissues. The samples used for this experiment were spleen, lung, heart, liver and kindney and those tissues were homogenized by a blender. The homogenized materials was extracted with mixed solvent, acetone/benzene (1:1) and cleaned up on a activated carbon column and determined by gas chromatography using AFID supported on 5% QF-1. The average recovery rate was 94% and the results obtained are summarized as follows. 1) The quantities of Malathin accumulated in each tissues were 0.53 ppm in spleen, 0.42 ppm in lung, 0.34 ppm in kidney, 0.19 ppm in heart and 0.19 ppm in liver. 2) Residues of pesticides in chronic or acute intoxicated tissues were highest in the spleen, decreasing in order of the lung, kidney, heart, and liver. 3) According to the above resuk we can conclude that the most proper material in detecting the pesticide is the spleen.

  • PDF

Charge Accunmulation Characteristics in LDPE (저밀도 폴리에틸렌의 전하축적 특성)

  • ;;Tatsuo Takada
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.1
    • /
    • pp.42-49
    • /
    • 1992
  • Charge accumulation characteristics in low density polyethylene (LDPE) has been discussed based upon the internal charge distrubution measured by the pulsed electroacoustic technique. When the negative voltage with respect to earth is applied to the upper electrode, the negative charges near the anode and the positive charges near the cathode are accumulated in LDPE. Also, there was an asymmetric behavior of charge accumulation exhibiting that the charge accumulation near the anode keeps increasing whereas that near the cathode increases first and then decreases. Besides, under the present test conditions the internal charge distrubution becomes stabilized eventually. When the positive voltage with respect to earth is applied to the upper electrode, on the other hand, no such asymmetric charge accumulation was found. Therefore, it can be concluded that the heterocharges are accumulated at the surface region of LDPE subjected to high do voltages and that the begavior of charge accumulation depends on the polarity of do voltage and the position of charge accumulation.

  • PDF

Energy-Based Seismic Design of Buckling-Restrained Braced Frame Using Hysteretic Energy Spectrum (이력에너지 스펙트럼을 이용한 비좌굴 가새골조의 내진설계)

  • 최현훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.63-69
    • /
    • 2003
  • In this study seismic design procedure for buckling-restrained braced frame systems was proposed using hysteretic energy spectrum and accumulated ductility spectrum constructed from single degree of freedom systems. The hysteretic energy spectra and accumulated ductility spectra corresponding to target ductility ratio were constructed first. The cross-sectional area of braces required to meet a given target displacement was obtained by equating the hysteretic energy demand to the accumulated plastic energy dissipated by braces. Twenty earthquake records were utilized to construct the spectra and to verify the validity of the design procedure. According to analysis results of three- and eight-story buckling-restrained braced frame structures designed using the proposed method, the mean values for the top story displacement correspond well with the given performance target displacements. Also, the inter-story drifts turned out to be relatively uniform over the structure height, which is desirable because uniform inter-story drifts indicate uniform damage distribution. Therefore if was concluded that the proposed energy-based method could be a reliable alternative to conventional strength-based design procedure for structures with buckling-restrained braces.

Accumulation and Organ distribution of protein Bound Cadmium in Rats compared with CdCl2 (단백질에 결합된 카드뮴과 CdCl2를 섭취한 쥐에서 카드뮴의 체내축적 및 분포의 차이)

  • 이명희
    • Journal of Nutrition and Health
    • /
    • v.27 no.8
    • /
    • pp.828-836
    • /
    • 1994
  • A low level exposure experiment was conducted on growing rats to investigate the accumulation and organ distribution of protein bound cadmium compared with cadmium chloride. Male Sprague-Dawley rats were fed for 21days with one of the semisynthetic diets, which contains cadmium as either bovine liver- or kidney meal bound cadmium, cadmium chloride with uncontaminated liver meal or cadmium chloride without organ meal, in the levels of ca. 0.5, 1 and 1.5mg/kg diet, respectively. After 21days of exposure cadmium was accumulated in liver, kidney and gastrointestinal tracts depending upon cadmium levels in diet. Inspite of very low cadmium accumulation in whole blood, it tends also to increase with dietary cadmium levels. The blood cadmium concentration of animals fed organ meal containing diets was about 4-7 fold higher than that without organ meal, regardless of cadmium was intrinsically bound to protein or not. However, significant effects of organ protein on cadmium accumulation in liver, kidney and digestive tracts were not detectable, when cadmium was supplemented as cadmium chloride. On the other hands, animals fed diet containing ca. 1.5mg Cd/kg as organ bound cadmium retained more cadmium in liver, kidney and digestive tracts compared to cadmium chloride with organ meal, whereby the increase of cadmium concentration in kidney was greater then in liver. However, when the concentration of protein bound cadmium was<1mg/kg diet, organ bound cadmium was not significantly different from cadmium chloride in bioavailability and organ distribution. From this result it is suggested that the intestinal absorption of protein bound cadmium is influenced of the amount of cadmium bound in protein. When cadmium concentration in protein is relatively low, protein bound cadmium seems to be absorbed in the same way as cadmium ions are absorbed. However, when the concentration is high, at least a small amount of intact protein bound cadmium could be absorbed and accumulated selectively in kidney.

  • PDF

Fresh water impact on chlorophyll a distribution at northeast coast of the Bay of Bengal analyzed through in-situ and satellite data

  • Mishra, R.K.;Senga, Y.;Nakata, K.
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.122-125
    • /
    • 2006
  • The distribution of phytoplankton pigments were studied bimonthly at four stations from the mouth of Mahanadi River at Paradip to the 36.7km off coast in Bay of Bengal during April 2001 to December 2002. Bottom depth was shallower than 40m in all stations. The pigment concentration of Chl-a was measured. It increased from surface to bottom in the water column. The water column integrated chlorophyll-a concentration (Chl-a) varied between 6.1 and $48.5mg{\cdot}m-^2$ with peaks during monsoon period (Aug & Oct). Spatial distribution of salinity depended strongly on freshwater runoff. The salinity was 5psu at river mouth and 25.15psu at offshore in monsoon period; however it was 30psu at the river mouth in summer. We found a linear relationship between the amount of river discharge and integrated Chl-a in coastal region from 2 years observations. Extending this result, we analyzed rainfall and coastal Chl-a using satellite data. The relationship between the river discharge and monthly accumulated rainfall estimated from TRMM and others data sources was analyzed in 2001 and 2002 using Giovanni infrastructure provided by NASA. The result depended on the specified area on TRMM images; the river delta area had sharper relationship than wider rain catchments area. Moreover, the relationship between monthly averaged Chl-a derived from SeaWiFS and monthly accumulated rainfall estimated from TRMM was analyzed from 1998 to 2005. It was clear that the broom in monsoon period was strongly controlled by rainfall on river delta.

  • PDF

Budget and distribution of organic carbon in Taxus cuspidata forest in subalpine zone of Mt. Halla

  • Jang, Rae-Ha;Jeong, Heon-Mo;Lee, Eung-Pill;Cho, Kyu-Tae;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.41 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • Background: In order to investigate organic carbon distribution, carbon budget, and cycling of the subalpine forest, we studied biomass, organic carbon distribution, litter production, forest floor litter, accumulated soil organic carbon, and soil respiration in Taxus cuspidata forest in Halla National Park from February 2012 to November 2013. Biomass was calculated by using allometric equation and the value was converted to $CO_2$ stocks. Results: The amount of plant organic carbon was $13.60ton\;C\;ha^{-1}year^{-1}$ in 2012 and $14.29ton\;C\;ha^{-1}year^{-1}$ in 2013. And average organic carbon introduced to forest floor through litter production was $0.71ton\;C\;ha^{-1}year^{-1}$. Organic carbon distributed in forest floor litter layer was $0.73ton\;C\;ha^{-1}year^{-1}$ on average and accumulated organic carbon in soil was $51.13ton\;C\;ha^{-1}year^{-1}$ on average. In 2012, Amount of released $CO_2$ from soil to atmosphere was 10.93 ton $CO_2ha^{-1}year^{-1}$. Conclusions: The net ecosystem production based on the difference between net primary production of organic carbon and soil respiration was $-1.74ton\;C\;ha^{-1}year^{-1}$ releasing more carbon than it absorbed.

A Study on Failure Rate Extraction of Power Distribution System Equipment (배전기기 고장률 추출에 관한 연구)

  • Moon, Jong-Fil;Kim, Jae-Chul;Lee, Hee-Tae;Chu, Cheol-Min;Ahn, Jae-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.366-368
    • /
    • 2007
  • In this paper, the Time-varying Failure Rate (TFR) of power distribution system equipment is extracted from the recorded failure data of Korea Electric Power Corporation (KEPCO). For TFR extraction, it is used that the fault data accumulated by KEPCO during 10 years. The TFR is approximated to bathtub curve using the exponential (random failure) and Weibull (aging failure) distribution function. In addition, Kaplan-Meier estimation is applied to TFR extraction because of incomplete failure data of KEPCO. Finally, Probability plot and regression analysis is applied. It is presented that the extracted TFR is more effective and useful than Mean Failure Rate (MFR) through the comparison between TFR and MFR.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가)

  • 임중관;박용필;김정호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

An Analysis of Insulating Reliability in Epoxy Composites for Molding Materials of PT

  • Yang, Jeong-Yun;Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.43-46
    • /
    • 2001
  • The DC dielectric breakdown of epoxy composites used for transformer was experimented and then its data were simulated by Weibull distribution equation in this study. The more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical, and the breakdown strength of specimens with filler was lower than it of non-filler specimens because it was believed that the adding filler formed interface, charges were accumulated in it, the molecular mobility was raised, the electric field was concentrated, electrons were accelerated and then electron avalanche was early accomplished. From the analysis of Wei bull distribution equation, it was confirmed that as the allowed breakdown probability was· given by 0.1[%], the value of 'applied field was needed to be under 17.20[kV/mm].

  • PDF

Analysis of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 분석)

  • 최철호;박용필;임중관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.414-419
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of (idled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF