A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

A General Method for Error Probability Computation of UWB Systems for Indoor Multiuser Communications

  • Durisi, Giuseppe;Tarable, Alberto;Romme, Jac;Benedetto, Sergio
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.354-364
    • /
    • 2003
  • A general method for the evaluation of the symbol error probability (SER) of ultra wideband (UWB) systems with various kind of modulation schemes (N-PAM, M-PPM, Bi-Orthogonal), in presence of multipath channel, multiuser and strong narrowband interference, is presented. This method is shown to be able to include all the principal multiaccess techniques proposed so far for UWB, time hopping (TH), direct sequence (DS) and optical orthogonal codes (OOC). A comparison between the performance of these multiple access and modulation techniques is given, for both ideal Rake receiver and minimum mean square error (MMSE) equalizer. It is shown that for all the analyzed multiple access schemes, a Rake receiver exhibits a high error floor in presence of narrowband interference (NBI) and that the value of the error floor is in-fluenced by the spectral characteristics of the spreading code. As expected, an MMSE receiver offers better performance, representing a promising candidate for UWB systems. When the multiuser interference is dominant, all multiple access techniques exhibit similar performance under high-load conditions. If the number of users is significantly lower than the spreading factor, then DS outperforms both TH and OOC. Finally 2PPM is shown to offer better performance than the other modulation schemes in presence of multiuser interference; increasing the spreading factor is proposed as a more effective strategy for SER reduction than the use of time diversity.

Java-based LonTaIk/IP Network for Predictive Maintenance (PM)

  • Park, Gi-Heung
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.31-35
    • /
    • 2001
  • Recent trends require that access to the device/equipment information be provided from several locations or anywhere in the enterprise. One example is virtual machine/manufacturing system (VMS) where predictive maintenance is performed both on factory floor and in remote site through internet [1]. Internet access is increasingly available and affordable, and along with the "internet" is the backbone of modern enterprise data networks. Typical functions of such a system includes monitoring and control for diagnosis and remedy action in realizing preventive maintenance.(omitted)

  • PDF

Multistage Parallel Nulling-Partial PIC Receiver for Downlink MIMO MC-CDMA Systems (하향링크 다중 안테나 MC-CDMA 시스템을 위한 다단계 병렬 널링 및 병렬 부분 간섭 제거 수신기 설계)

  • 구정회;김경연;심세준;이충용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.11
    • /
    • pp.1-7
    • /
    • 2004
  • We propose multistage parallel nulling (MPN) partial parallel interference cancellation (PPIC) receiver for downlink multiple-input multiple-output (MIMO) multicarrier (MC)-code division multiple access (CDMA) systems. Though the V-BLAST is a popular MIMO receiver, it shows error floor for multiuser downlink MIMO MC-CDMA systems. The proposed MPN-PPIC receiver does not produce error floor for multiuser case, and achieves substantial performance gains with multistage processing. For single user case, the proposed method also surpasses the V-BLAST receiver with multistage processing for MIMO MC-CDMA systems with chip level interleaving. The system performance of the proposed MPN-PPIC receiver is evaluated through computer simulations.

Effect of Different Housing System on the Performance, Bone Mineral Density and Yolk Fatty Acid Composition in Laying Hen

  • Hassan, Md. Rakibul;Sultana, Shabiha;Choe, Ho Sung;Ryu, Kyeong Seon
    • Korean Journal of Poultry Science
    • /
    • v.39 no.4
    • /
    • pp.261-267
    • /
    • 2012
  • Different housing systems have considerable influence on performance in poultry production. Therefore, the present study was undertaken to investigate the impact of different housing systems on the performance, bone mineral density and egg yolk fatty acid composition in laying hen. Hy-line brown pullets (n=450) of 12 weeks age were randomly divided into 3 housing systems with 6 replicates of 25 birds in each room. A diet with 2,750 kcal/kg ME and 16.5% CP was assigned to all birds. The pullets provided free access to feed and water. Significantly (P<0.05) higher values for egg production, egg mass and feed conversion efficiency were found in battery cages, however egg weight, egg shell color and breaking strength was remarkably (P<0.05) higher in floor system. The albumin height and Haugh unit were significantly higher (P<0.05) in battery cages which was statistically similar to aviary housing system. The egg yolk fatty acids concentration of linoleic acid and linolenic acids were significantly higher in aviary and in floor system, respectively, however both values were lower in battery cages. Saturated and unsaturated fatty acid content (%) in egg yolk did not influence by any housing systems. Bone mineral density was significantly higher (P<0.05) in floor and aviary housing system than that of battery cage system. It was concluded that in battery cages the egg production and composition maximized, however higher bone mineral density and yolk fatty acids content can be improved in the laying hen reared on floor and aviary housing systems.

Estimation Study of Willingness to Pay for Low-Floor Seat Buses Introduction (저상 좌석버스 도입에 대한 지불의사금액 추정 연구)

  • Dong Jun Choi;Yongju Yi;Jeong Ah Jang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.6
    • /
    • pp.66-76
    • /
    • 2023
  • The government recently implemented policies to improve transportation for the disabled passengers. On the other hand, metropolitan public transport still lacks adequate services for these individuals. Many new cities lack urban rail lines and focus on high-floor buses for expansion. Wheelchair users can only access to double-decker low-floor seat express buses for intercity travel. This study examined the necessity and rationale for introducing low-floor seat buses by estimating the user's willingness to pay through a contingent valuation method. Two methods for eliciting the willingness to pay were adopted: open-ended and dichotomous choice questions. The binomial logit model was used to estimate the willingness to pay. The results indicated that the general public is willing to pay an additional 126.7 Korean won, while the disabled passengers are willing to pay an additional 117.5 Korean won. When translated into annual economic benefits, this amounts to approximately 35 billion Korean won.

A study on the simulator development for fire evacuation of the high-rise buildings (초고층 건물의 화재 대피 시뮬레이터 개발에 관한 연구)

  • 박양수;임동진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.308-308
    • /
    • 2000
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

Design of Web Service by Using OPC XML-DA and OPC Complex Data for Automation and Control Systems

  • Tan Vu Van;Yoo Dae-Sung;Yi Myeong-Jae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06a
    • /
    • pp.250-252
    • /
    • 2006
  • Web technologies are gaining increased importance in automation and control systems. However, the choice of Web technologies depends on the use cases in the application environment. In industrial systems, the data can be got not only from many different field systems and devices but also from different OPC (OLE for Process Control) Servers. Current OPC Client might be able to read simple data from OPC Server, but there are some problems to get structured data and to exchange structured information between collaborating applications. Therefore, OPC Foundation has defined interfaces to OPC XML-DA (OPC XML Data Access) and OPC Complex Data that aim to solve those problems. The OPC XML-DA can facilitate the exchange of plant data across the internet, and upwards into the enterprise domain. In addition, the OPC Complex Data will extend the OPC DA specification to allow the OPC Client to read and decode any type of data from measurement and control systems on the plant floor. This paper will describe the concept of OPC XML-DA and OPC Complex Data. And then it proposes a mechanism to implement the OPC Complex Data into OPC XML-DA Server. Additionally, the paper also discusses the security aspects.

  • PDF

A Teleoperated Cleaning Robot for a High Radioactive Environment

  • Kim, Ki-Ho;Park, Jang-Jin;Yang, Myung-Seung;Oh, Chae-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.849-854
    • /
    • 2003
  • The Korea Atomic Energy Research Institute has developed a teleoperated cleaning robot for use in the radioactive zone of the isolation room of the Irradiated Material Examination Facility where direct human access to the interior is strictly limited. The teleoperated cleaning robot that was designed to completely eliminate human interaction with the hazardous radioactive contaminants has five remotely replaceable submodules - a mobile module for navigation, a cleaning module for dislodging and sucking contaminated waste, a sensing module for obstacle avoidance, a collection module for storing the acquired waste, and a cover module for protecting the collection module. This cleaning robot is capable of cleaning the contaminated floor surface of the isolation room and collecting loose dry spent nuclear fuel debris and other radioactive waste fixed or scattered on the floor surface. The developed cleaning robot is operated either by a manual control or by autonomous control in conjunction with a graphical simulator, by which the human operator can monitor and intervene the robot performing cleanup tasks in the isolation room. In this paper, we present the mechanical and environmental design considerations and development of the teleoperated cleaning robot for radioactive isolation room use. We also demonstrate its mock-up performance test results from the viewpoint of a remote cleanup operation and remote maintenance.

  • PDF