• Title/Summary/Keyword: Acceptable thermal range

Search Result 30, Processing Time 0.023 seconds

Effect of Electric Charge on the Operating Behavior of Air-conditioner and Thermal Comfort in Summer Season (여름철 전기요금이 거주자의 냉방기 조작과 온열감에 미치는 효과)

  • Kwon, Suh-Hyun;Bae, Nu-Ri;Chun, Chung-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.703-709
    • /
    • 2007
  • Much energy is used in occupying stage of the Building Life Cycle. Electric charge is one of the various factors that influence on energy use of residents. This study focused on electric charge and searched that whether electric charge affects residents' behavior of operating air conditioner and their controlled indoor climate. We surveyed three groups for field study ; A group is residents who live in a studio apartment, B group is residents who live in a university dormitory and C group is residents who live in a apartment with their family. The A and C groups are charged for electric as energy consumption they used. And the B group is students who live in a university dormitory and they are not charged for their energy consumption. We measured the time to use the air conditioner for cooling, on/off temperature of air conditioner, and room air temperature for these three groups. The result shows that consideration for electric charge affects to the residents' behavior of operating air conditioner and their acceptable thermal range.

A comparison of resident's behavior of operating air conditioner according to the charge for electric (사용자의 전기요금 부담 여부에 따른 여름철 냉방기 사용 특성의 비교)

  • Kwon, Suh-Hyun;Choi, Yoo-Rim;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.301-305
    • /
    • 2006
  • An electrical bill is one of the various factors that influence on energy use of residents. This study focused on electrical bills and searched that whether electrical bills affect resident behavior of operating air conditioner and their controlled indoor climate. We surveyed two groups for field study ; the one is residents who live in a studio apartment in Seoul and they are charged for electric as energy consumption they used, and the other is residents who live in a university dormitory and they are not charged for their energy consumption. We measured how long they used the air conditioner for cooling, on/off temperature of air conditioner and room temperature for these two groups. Residents were interviewed about their cooling needs, decisions about when to turn on their air conditioner and so on. We found that dormitory group has much amount of time used the air conditioner than studio apartment group and there are differences of room temperature between two groups when they turn on or off air conditioner. The result shows that perception of money affects resident behavior of operating air conditioner and their acceptable thermal range.

  • PDF

An Experimental Study on Combustion and Exhaust Emissions Characteristics in RCCI (Reactivity Controlled Compression Ignition) of Dual-Fuel (Diesel+Gasoline) (2중연료(디젤+가솔린)의 RCCI 연소 및 배기 특성에 관한 실험적 연구)

  • Sung, K.A.
    • Journal of ILASS-Korea
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • An experimental study was performed to explore characteristics of combustion and exhaust emissions in the compression ignition engine of RCCI (reactivity controlled compression ignition) using diesel-gasoline dual fuel. A dual-fuel reactivity controlled compression ignition concepts is demonstrated as a promising method to achieve high thermal efficiency and low emissions. For investigating combustion characteristics, engine experiments were performed in a light-duty diesel engine over a range of SOIs (start of injection) and gasoline percents. The experimental results showed that cases of diesel-gasoline dual fuel combustion is capable of operating over a middle range of engine loads with lower levels of NOx and soot, acceptable pressure rise rate, low ISFC (indicated specific fuel consumption), and high indicated thermal efficiency.

A Method for Determining Appropriate Maintenance Intervals of Equipments in Thermal Power Stations

  • Nakamura, Masatoshi;Katafuchi, Tatsuro;Hatazaki, Hironori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.312-317
    • /
    • 1998
  • Reliable maintenance scheduling of main equipments is a crucial problem in thermal power stations in order to skirt overall losses of power generation resulted from severe failures of the equipments. A reasonable method was proposed to determine the maintenance scheduling of whole pump system in thermal power stations in order to reduce the maintenance cost by keeping the present avail-ability of the pump system throughout the operation. The dimensional reduction method was used to solve problems encountered due to few data which involved many operational factors in failure rate of pumps. The problem of bandlimited nature of data with time was solved by extrapolating future failures from presently available actual data with an aid of Weibull distribution. The results of the analysis identified the most suitable maintenance intervals of each pump type accordingly and hence reduce the cost of unnecessary maintenance with an acceptable range in the overall system availability.

  • PDF

Modeling on thermal conductivity of MOX fuel considering its microstructural heterogeneity

  • Lee, Byung-Ho;Koo, Yang-Hyun;Sohn, Dong-Seong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.10a
    • /
    • pp.247-247
    • /
    • 1999
  • This paper describes a new mechanistic thermal conductivity model considering the heterogeneous microstructure of MOX fuel. Even though the thermal conductivities of MOX have been investigated numerously by experimental measurements and theoretical analyses, they show the large scattering making the performance analysis of MOX fuel difficult. Therefore, a thermal conductivity model that depends on the heterogeneous microstructure of MOX fuel has been developed by using a general two-phase thermal conductivity model. In order to apply this model for developing the thermal conductivity for heterogeneous MOX fuel, the fuel is assumed to consist of Purich particles and U02 matrix including Pu02 in solid solution. Since little relevant data on Purich particles is available, FIGARO and SiemensKWU results are only used to characterize the microstructure of unirradiated and irradiated fuel. Philliponneaus and HALDEN models are selected for the local thermal conductivities for Purich particles and matrix, respectively. Then by combining the two models, overall thermal conductivity of MOX fuel is obtained. The new proposed model estimates the MOX thermal conductivity about 10% less than the value of U02 fuel, which is in the range of MOX thermal conductivity from HALDEN. The developed thermal conductivity model has been incorporated into KAERIs fuel performance code, COSMOS, and then verified using the measured data in the FIGARO program. Comparison of predicted and measured temperatures shows the reasonable agreement within acceptable error bounds together with satisfactory results for the fission gas release and gap pressure.essure.

  • PDF

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Effect of initial ground temperature measurement on the design of borehole heat exchanger (초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향)

  • Song, Yoon-ho;Kim, Seong-Kyun;Lee, Kang-Kun;Lee, Tae-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

Preparation and Nonlinear Optical Properties of Novel Polyesters with Enhanced Thermal Stability of Second Harmonic Generation

  • Kim, Jin-Hyang;Won, Dong-Seon;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.181-186
    • /
    • 2008
  • 2,5-Di-(2'-hydroxyethoxy)-4'-nitrostilbene (3) was prepared and polycondensed with terephthaloyl chloride, adipoyl chloride, and sebacoyl chloride to yield novel T-type polyesters (4-6) containing the NLO-chromophores dioxynitrostilbenyl groups, which constituted parts of the polymer backbones. Polymers 4-6 are soluble in common organic solvents such as acetone and N,N-dimethylformamide. They showed thermal stability up to 260 oC in thermogravimetric analysis with glass-transition temperatures obtained from differential scanning calorimetry in the range 90-95 oC. The second harmonic generation (SHG) coefficients (d33) of poled polymer films at the 1064 nm fundamental wavelength were around 1.42 ´ 10-9 esu. The dipole alignment exhibited high thermal stability up to 5 oC higher than glass-transition temperature (Tg), and there was no SHG decay below 100 oC due to the partial main-chain character of polymer structure, which is acceptable for NLO device applications.

Low Temperature Thermal Conductivity of Sheath Alloys for High $T_{c}$ Superconductor Tape

  • Park, Hyung-Sang;Oh, Seung-Jin;Jinho Joo;Jaimoo Yoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.2
    • /
    • pp.32-37
    • /
    • 2000
  • Effect of alloying element additions to Ag on thermal conductivity and electrical conductivity of sheath materials for Bi-Pb-Sr-Ca-Cu-O(BSCCO) tapes has been characterized. The thermal conductivity at low temperature range (10~300K) of Ag and Ag alloys were evaluated by both direct and indirect measurement techniqueas and compared with each other, It was observed that the thermal conductivity decreases with increasing the content of alloying element such as Au, Pd and Mg. Thermal conductivity of pure Ag at 3 0K was measured to be 994.0 W(m.K) on the other hand, the corresponding values of $Ag_{0.9995}Mg_{0.0005}$, $Ag_{0.974}$, $Au_{0.025}$, $Mg_{0.001}$, $Ab_{0.973}$, $Au_{0.025}$, $Mg_{0.002}$ and $Ag_{0.92}$, $Pb_{0.06}$, $Mg_{0.02}$ were 342.6, 62.1, 59.2 and 28.9 W(m.K), respectively, indicating 3 to 30 times lower than that of pure Ag. In addition, the thermal conductivity of pure Ag measured by direct and indirect measurement techniques was 303.2 and 363.8 W(m.K) The difference in this study is considered to be within an acceptable error range compared to the reference data.

  • PDF

Preparation of Novel T-type Polyurethanes with High Thermal Stability of Second Harmonic Generation and Their Nonlinear Optical Properties

  • Jang, Han-Na;Lee, Ga-Young;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.4
    • /
    • pp.811-816
    • /
    • 2008
  • 2,5-Di-(2'-hydroxyethoxy)benzylidenemalononitrile (3) was prepared and polymerized with 2,4-toluenediisocyanate and 3,3'-dimethoxy-4,4'-biphenylenediisocyanate to yield novel T-type polyurethanes 4 and 5 containing 2,5-dioxybenzylidenemalononitrile, nonlinear optical (NLO)-chromophores as part of the polymer backbones. Polyurethanes 4 and 5 were soluble in common organic solvents such as acetone and N,Ndimethylformamide and showed a thermal stability up to $250{^{\circ}C}$ with glass-transition temperatures ($T_g$) in the range $119-146{^{\circ}C}$. The second harmonic generation (SHG) coefficients ($d_{33}$) of poled polymer films at 1064 nm fundamental wavelength were around $5.82{\times}10^{-9}$ esu. The dipole alignment exhibited high thermal stability up to $T_g$, and there was no SHG decay below $140{^{\circ}C}$ due to the partial main-chain character of the polymer structure, which was acceptable for nonlinear optical device applications.