• 제목/요약/키워드: Acceptable limits

검색결과 234건 처리시간 0.031초

선형계획법을 이용한 무효전력 설비 계획 (Reactive Power Planning Using Linear Programming)

  • 김정부;박영문
    • 대한전기학회논문지
    • /
    • 제38권10호
    • /
    • pp.805-810
    • /
    • 1989
  • This paper presents a method for planning reactive power compensation such as shunt capacitors and reacters so as to maintain bus voltage in acceptable range during steady state operation in power system. The algorithm in this paper decomposes the problem into reactive power planning module for the compensation of bus voltage and load flow module for adjusting the error resulted from the linear approximation. A planning technique is based on linear programming to minimize the amount of added reactive power compensation in each case. Transformer tap settings and generator voltages are adjusted to minimize the compensation. The constraints are the operation limits of the control variables and bus voltages. The result of one sample system is presented to confirm the practical use of the proposed algorithm.

  • PDF

모세관전기영동장치 및 고속액체 크라마토그래피에 의한 황금의 성분 분석법 비교 (Studies on the Comparison of Scutellaria Radix Analyses by CE and HPLC)

  • 면노홍;김효진
    • 약학회지
    • /
    • 제43권4호
    • /
    • pp.429-436
    • /
    • 1999
  • A simple, accurate and reproducible Capillary electrophoresis (CE) assay has been developed for the determination of baicalin, baicalein, wogonin and chrysin in Scutellaria baicalensis. Successful separation of these compounds has been obtained in 35 mM phosphate butter (pH 7.0) using a untreated fused silica capillary ($57{\;}cm{\times}75{\;}{\mutextrm{m}}$ i.d.) at $25^{\circ}C$ with the electric field of 19kV. Baicalin, baicalein wogonin and chrysin was separated and detected at 280 nm 13 min. The detection limits of CE were acceptable compared to HPLC. Reproducibilities of migration time and peak area were 0.66~1.11% (within-run), 2.18~3.38% (between-run) and 3.50~4.55% (within-run), 3.97~4.82%(between-run) at CE. The results indicate that CE could be a promising technique for quality and quantity control analysis of Scutellaria baicalensis as a validation method.

  • PDF

불건전(不健全)한 인터넷 자원(資源)으로부터의 청소년(靑少年) 보호방안(保護方案)에 관한 연구(硏究) (A Study on the Protection Methods for Students from Inappropriate Internet Sites)

  • 주영주;곽은순
    • 교육시설
    • /
    • 제6권1호
    • /
    • pp.5-20
    • /
    • 1999
  • With the advent of internet, the modern society is enjoying the benefits of the information age. As one of undesirable side effects of utilization of internet, however, it is often mentioned that young students are helplessly exposed to inappropriate and unqualified information. Therefore, in this paper, we will clarify the nature of inappropriate information to the younger generation and will argue for the needs of protecting the youth from inappropriate information. Especially the merits and limits of often motioned five different protective and regulatory measures are presented and analyzed, those are, establishment of acceptable use policy, active utilization of supervisory organization, promotion of Internet rating system, installation of filtering software, and legal and regulatory protection. As a fundamental means of resolving the problems, however, enforcement of systematic information literacy education, promotion of active utilization of sound information, development of search engines for the youth, design of diverse filtering softwares which can be selected by users, and increased attention by parents and teachers are suggested.

  • PDF

신뢰도지수를 고려한 배전계통시스템의 최적전력전송경로 결정 (Optimal Routing of Distribution Networks Considering Reliability Indices)

  • 노병권;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.915-917
    • /
    • 1998
  • Optimal routing of distribution networks can be attained by keeping the line power capacity limit to handle load requirements, acceptable voltage at customer loads, and the reliability indices such as SAIFI, SAIDI, CAIDI, and ASAI limits. This method is composed of optimal loss reduction and optimal reliability cost reduction. The former is solved relating to the conductor resistance of all alternative routes, and the latter is solved relating to the failure rate and duration of each alternative route. The routing considering optimal loss only and both optimal loss and optimal reliability cost are compared in this paper. The results showed that reliability cost should be considered as well as loss reduction to achieve the optimal routing in the distribution networks.

  • PDF

무전극형광램프 ULTRA 150W용 EMI 필터에 대한 연구 (A Study on EMI Filters' construction of 150W Electrodeless fluorescent lamp UTLRA's Ballasts)

  • 박석인;한수빈;유승원;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.217-221
    • /
    • 2006
  • Offline switching Power supplies have high voltage and high current switching waveforms that generate Electromagnetic Interference(EMI) in the form of both conducted and radiated emissions. Consequently, all off-line power supplies must be designed to attenuate or suppress EMI emissions below commonly acceptable limits. Electrodeless fluorescent lamp's ballasts have AC/DC flyback converter, so we must control the EMI emissions.

  • PDF

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.

Optimization of Process Parameters for Dry Film Thickness to Achieve Superior Water-based Coating in Automotive Industries

  • Prasad, Pranay Kant;Singh, Abhinav Kr;Singh, Sandeep;Prasad, Shailesh Kumar;Pati, Sudhanshu Shekher
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.121-129
    • /
    • 2022
  • A study on water-based epoxy coated on mild steel using the electroplating method was conducted to optimize the process parameters for dry film thickness to achieve superior paint quality at optimal cost in an automotive plant. The regression model was used to adjust various parameters such as electrode voltage, bath temperature, processing time, non-volatile matter, and surface area to optimize the dry film thickness. The average dry film thickness computed using the model was in the range of 15 - 35 ㎛. The error in the computed dry film thickness with reference to the experimentally measured dry film thickness value was - 0.5809%, which was well within the acceptable limits of all paint shop standards. Our study showed that the dry film thickness on mild steel was more sensitive to electrode voltage and bath temperature than processing time. Further, the presence of non-volatile matter was found to have the maximum impact on dry film thickness.

Estimation of Effective Dose to Residents Due to Hypothetical Accidents During Dismantling of Steam Generator

  • Kyeong-Ju Lee;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제21권2호
    • /
    • pp.183-191
    • /
    • 2023
  • The potential impact of hypothetical accidents that occur during the immediate and deferred dismantling of the Kori Unit 1 steam generator has been comprehensively evaluated. The evaluation includes determining the inventory of radionuclides in the Steam Generator based on surface contamination measurements, assuming a rate of release for each accident scenario, and applying external and internal exposure dose coefficients to assess the effects of radionuclides on human health. The evaluation also includes calculating the atmospheric dispersion factor using the PAVAN code and analyzing three years of meteorological data from Kori NPP to determine the degree of diffusion of radionuclides in the atmosphere. Overall, the effective dose for residents living in the Exclusion Area Boundary (EAB) of Kori NPP is predicted, an it is found that the maximum level of the dose is 0.034% compared to the annual dose limit of 1 mSv for the general public. This implies that the potential impact of hypothetical accidents on human health discussed above is within acceptable limits.

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

HOLISTIC DECISION SUPPORT FOR BRIDGE REMEDIATION

  • Maria Rashidi;Brett Lemass
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.52-57
    • /
    • 2011
  • Bridges are essential and valuable elements in road and rail transportation networks. Bridge remediation is a top priority for asset managers, but identifying the nature of true defect deterioration and associated remediation treatments remains a complex task. Nowadays Decision Support Systems (DSS) are used extensively to assist in decision-making across a wide spectrum of unstructured decision environments. In this paper a requirements-driven framework is used to develop a risk based decision support model which has the ability to quantify the bridge condition and find the best remediation treatments using Multi Attribute Utility Theory (MAUT), with the aim of maintaining a bridge within acceptable limits of safety, serviceability and sustainability.

  • PDF