• 제목/요약/키워드: Acceptable Range

검색결과 854건 처리시간 0.028초

배전선로 공급 신뢰도에 관한 연구 (Study for the reliability indices in the distribution system)

  • 조남훈;윤태상;하복남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.70-72
    • /
    • 2000
  • The basic function of a modern electric power system is to provide electric power to its customers at the lowest possible cost with acceptable reliability levels. The two aspects of economics and reliability often conflict and present power system managers, planners and operators with a wide range of challenging problems. Utilities may also be willing to provide higher reliability of power supply at no increased customer cost. Decision-making is a difficult task. In this paper, we present a method to calculate the optimal values of reliability indices for sectionalizing distribution line.

  • PDF

저강도 플라이애시-시멘트 복합체의 내구특성 (Durability Characteristics of Low Strength Fly ash-Cement Composites)

  • 원종필;신유길;이용수;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.142-147
    • /
    • 2000
  • Durability characteristics of controlled low strength material(flowable fill) with high volume fly ash content was examined. The mix proportions used for flowable fill are selected to obtain low-strength material in the 10 to 15kgf/㎥ range. The optimized flowable fill was consisted of 60kgf/㎥ cement content, 280kgf/㎥ fly ash content, 1400kgf/㎥sand content, and 320kgf/㎥water content. Subsequently, durability tests including permeability warm water immersion, repeated wetting & drying, freezing & thawing for high volume fly ash-flowable fill are conducted The test results indicated that flowable fill has has acceptable durability characteristics.

  • PDF

Efficient Global Optimization of Periodic Plasmonic Nanoslit Array Based on Quality Factor Analysis

  • Jaehoon Jung
    • Current Optics and Photonics
    • /
    • 제7권3호
    • /
    • pp.248-253
    • /
    • 2023
  • An efficient global optimization approach for a periodic plasmonic nanoslit array based on extraordinary optical transmission within an acceptable time range is proposed using 𝚀 factor analysis method. The particle swarm optimization is employed as a global optimization tool. The figure of merit is defined as a product of transmission peak value and 𝚀 factor. The design variables are the slit width, height, and period of the slit array, respectively. The optical properties such as transmission spectrum and bandwidth are calculated rigorously using the finite element method.

자동화학 분석기 Toshiba 120 FR의 평가 (Evaluation of Autochemical Analyzer Toshiba 120 FR)

  • 박점기
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF

2중연료(디젤+가솔린)의 RCCI 연소 및 배기 특성에 관한 실험적 연구 (An Experimental Study on Combustion and Exhaust Emissions Characteristics in RCCI (Reactivity Controlled Compression Ignition) of Dual-Fuel (Diesel+Gasoline))

  • 성기안
    • 한국분무공학회지
    • /
    • 제16권1호
    • /
    • pp.51-57
    • /
    • 2011
  • An experimental study was performed to explore characteristics of combustion and exhaust emissions in the compression ignition engine of RCCI (reactivity controlled compression ignition) using diesel-gasoline dual fuel. A dual-fuel reactivity controlled compression ignition concepts is demonstrated as a promising method to achieve high thermal efficiency and low emissions. For investigating combustion characteristics, engine experiments were performed in a light-duty diesel engine over a range of SOIs (start of injection) and gasoline percents. The experimental results showed that cases of diesel-gasoline dual fuel combustion is capable of operating over a middle range of engine loads with lower levels of NOx and soot, acceptable pressure rise rate, low ISFC (indicated specific fuel consumption), and high indicated thermal efficiency.

레이다 성능 안정화를 위한 잡음 AGC (Noise Automatic Gain Control to Stabilize Radar Performance)

  • 김관성
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.132-137
    • /
    • 2007
  • The dynamic range of the radar which uses digital signal processors is limited by ADC(Analog-to-Digital Converter). That parameter and ADC loss depend on the noise level of radar receiver. In order to stabilize the performance of radar systems, it is necessary to maintain the noise level constantly. This paper presents the noise AGC(Automatic Gain Control) concept that can keep the noise level constantly and proves that the concept is acceptable through the hardware test and evaluation.

Variable Structure PWM Controller for Highly Efficient PV Inverters

  • Oh, Seong-Jin;SunWoo, Myoung-Ho
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.866-873
    • /
    • 2009
  • In general, the output voltage level of a PV array varies widely at various irradiances and temperatures. The MPP (Maximum Power Point) range of a medium- or high-power PV PCS is normally 450~830Vdc or 300~600Vdc. This means the PV PCS should operate in a wide range of modulation indexes. The PV PCS should satisfy the harmonic current requirement that the TDD (Total demand distortion) shall not exceed 5%. This paper proposes a new PWM control method for a medium- or high-power PV PCS which increases the efficiency of power conversion in all operation ranges with acceptable harmonic ripple currents. This paper compares and analyzes appropriate PWM schemes for the PV PCS in the view points of conversion efficiency and current harmonics.

IH-Jar용 Class-D 인버터의 새로운 PWM 출력 제어 기법 (A New PWM Power Control Scheme of Class-D Inverter for Induction Heating Jar Application.)

  • 최원석;박남주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.519-523
    • /
    • 2004
  • In this paper, a simple power control scheme of Class-D inverter, which is varied duty cycle of fixed frequency to desired output power. It is more suitable and acceptable for high-frequency induction heating (IH) jar applications. The proposed control scheme has the advantages of not only wide power regulation range but also ease to control output power. Also it can achieve the stable and efficient Zero-Voltage-Switching (ZVS) in whole load range. The control principles of proposed method are described in detail and its validity is verified trough simulations results on 38.5kHz IGBT for induction heating rated on 1.6kW with constant frequency variable power.

  • PDF

Optical Purity Determination of (S)-Ibuprofen in Tablets by Achiral Gas Chromatography

  • Paik, Man-Jeong;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • 제27권8호
    • /
    • pp.820-824
    • /
    • 2004
  • An optical purity test was indirectly performed on (S)-ibuprofen as its diastereomeric (R)-(+)-1-phenylethylamide derivative using achiral gas chromatography (GC). The method for the determination of trace (R)-ibuprofen (optical impurity), within the range 1.0 to 50 ng, from a racemic ibuprofen standard was linear (r=0.9997) with acceptable precision (% $RSD{\leq}5.3$) and accuracy (% RE=0.7~-3.9). Similar results were obtained with the method validation for the quantification of (S)-ibuprofen within the range 0.1 to 2.0 $\mu\textrm{g}$ using a (S)-ibuprofen stan-dard. When applied to seven different commercial (S)-ibuprofen products, their optical purities (98.7~99.1%) were determined with good precision (% $RSD{\leq}4.0$).

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF