• Title/Summary/Keyword: Acceleration sound

Search Result 114, Processing Time 0.023 seconds

New Method for Measurement and Validation of In-situ Sound Transmission Loss (In-situ 소음투과손실 측정 및 검증을 위한 기법 개발)

  • Lee, Hwa-Soo;Park, Hong-Cheol;Yoon, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

The Research for Predicting Customer's Evaluation of Sound Quality for a New Vehicle (신 개발 차종에 대한 소비자 음질평가 예측에 관한 연구)

  • Lee, Sang-Kwon;Jo, Byoung-Ok;Park, Dong-Chul;Lee, Min-Sub;Jung, Seung-Gyoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1437-1442
    • /
    • 2006
  • The international competition in car markets has continuously required the research about the sound quality of a car. The domestic carmakers have also invested a lot of money for the research and development of interior sound quality of passenger cars. Therefore, the aim of this research is to predict the customer's evaluation of a new vehicle. There are two major research works to achieve this goal in this research. The first one is to search questionnaires about the sound quality, which customers prefer, to identify the relationship between these questionnaires and sound metrics that is a psychoacoustics parameters, and to development sound indexes for the questionnaires. All tests for this work is proceed on the road test during acceleration. The second one is to balance the sound component (engine noise, booming noise, road noise and wind noise) of a passenger. This wok will be tested on the constant speed. All of research results will be contributed to the development of brand sound quality of a new passenger car.

  • PDF

Proposition of a Vibration Based Acceleration Sensor for the Fully Implantable Hearing Aid (완전 이식형 보청기를 위한 진동 기반의 가속도 센서 제안)

  • Shin, Dong Ho;Mun, H.J.;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.133-141
    • /
    • 2017
  • The hybrid acoustic sensor for implantable hearing aid has the structure in which a sound pressure based acoustic sensor (ECM) and a vibration based acceleration sensor are combined. This sensor combines the low frequency sensitivity of an acoustic sensor with the high frequency sensitivity of an acceleration sensor, allowing the acquisition of a wide range of sound from low to high frequency. In this paper, an acceleration sensor for use in a hybrid acoustic sensor has been proposed. The acceleration sensor captures the vibration of the tympanic membrane generated by the acoustic signal. The size of the proposed acceleration sensor was determined to diameter of 3.2 mm considering the anatomical structure of the tympanic membrane and the standard of ECM. In order to make the hybrid acoustic sensor have high sensitivity and wide bandwidth characteristics, the aim of the resonance frequency of the acceleration sensor is to be generated at about 3.5 kHz. The membrane of the acceleration sensor derives geometric structure through mathematical model and finite element analysis. Based on the analysis results, the membrane was implemented through a chemical etching process. In order to verify the frequency characteristics of the implemented membrane, vibration measurement experiment using external force was performed. The experiment results showed mechanical resonance of the membrane occurred at 3.4 kHz. Therefore, it is considered that the proposed acceleration sensor can be utilized for a hybrid acoustic sensor.

Vibrational Characteristics of High-Speed Motors with Ball Bearings and Gas Foil Bearings Supports (볼 베어링 및 가스 포일 베어링으로 지지되는 소형 고속 전동기의 진동 특성)

  • Seo, Jung Hwa;Kim, Tae Ho
    • Tribology and Lubricants
    • /
    • v.35 no.2
    • /
    • pp.114-122
    • /
    • 2019
  • High-speed rotating machinery requires low cost and reliable bearing elements with low friction, stable rotordynamic characteristics, and a simple design. This study experimentally evaluates the effects of bearing-support elements on the vibrational characteristics of a small-sized, high-speed permanent magnetic motor. A series of coast down tests from 100 krpm characterize the vibrational behaviors, rotor displacement, and housing acceleration of motors supported by ball bearings, ball bearings with a metal mesh damper, and gas foil bearings, respectively. Two eddy-current sensors installed in the horizontal and vertical directions measure the displacement of the rotor at its front nut, and a 3-axis accelerometer attached to the motor housing measures the housing acceleration. The test results reveal that synchronous (1X) vibration components most significantly affect the rotor displacement and housing acceleration, independent of the bearing-support elements. The motor supported by the deep-groove ball bearings results in the largest rotor vibrations increasing with speed; this is due to the absence of a damping mechanism. Additionally, the metal mesh damper effectively reduces the rotor displacement, housing acceleration, and sound-pressure level in the high-speed region (i.e., above 40 krpm), thus implying its substantial damping performance when installed on the outer race of the ball bearing. Lastly, the gas foil bearing supported motor yields the smallest rotor displacement, housing acceleration, and lowest sound-pressure level because of its hydrodynamic airborne operation, which does not require rolling elements that may cause mechanical friction and vibrations.

Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials (감쇠재 사용에 따른 중량충격음의 소음 및 진동특성)

  • Jeon, Jin-Yong;Jeong, Young;Song, Hee-Soo;Kim, Min-Bae;Lee, Young-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF

Damage Count Method Using Acceleration Response for Vibration Test Over Multi-spectral Loading Pattern (복합 스펙트럼 패턴의 진동 시험을 위한 가속도 응답 데이터 기반의 피로 손상도 계산 방법)

  • Kim, Chan-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.11
    • /
    • pp.739-746
    • /
    • 2015
  • Several damage counting methods can be applied for the fatigue issues of a ground vehicle system using strain data and acceleration data is partially used for a high cyclic loading case. For a vibration test, acceleration data is, however, more useful than strain one owing to the good nature of signal-to-random ratio at acceleration response. The test severity can be judged by the fatigue damage and the pseudo-damage from the acceleration response stated in ISO-16750-3 is one of sound solutions for the vibration test. The comparison of fatigue damages, derived from both acceleration and strain, are analyzed in this study to determine the best choice of fatigue damage over multi-spectral input pattern. Uniaxial excitation test was conducted for a notched simple specimen and response data, both acceleration and strain, are used for the comparison of fatigue damages.

Transfer Path Analysis of vibration and noise for medical air compressor using PAK system (PAK system 을 이용한 의료용 컴프레서의 진동.소음 전달경로 해석)

  • Kang, Kwi-Hyun;Kang, Jin-Chul;Park, Chun-Kwon;Lee, Jeong-Hwan;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1000-1004
    • /
    • 2008
  • As performance of medical air compressor improve, the problem of noise increased. Noise is very important to medical air compressor because most of this installed inside of building. The main goal of this paper is show TPA (Transfer Path Analysis) result for contribution analysis using PAK system. Generally, the conventional TPA method consists of two steps. First, transfer functions between output sound and sources are measured by excitation experiment. Second, transferred sound in each transfer path is generated by multiplying the transfer function and the sound source signal. Then, if the output sound synthesized from all transferred sounds doesn't give good agreement with the measured output sound (i.e., the accuracies of the transfer functions are low), setting a suitable countermeasure guideline becomes difficult. For obtaining highly accurate transfer functions, eliminating correlations among transfer functions and noise included in the measured data are necessary. In the new method with PAK system, the vibration acceleration and sound signals around the sound sources and the output sound were measured simultaneously to obtain the transfer functions when compressor was operating. By applying PAK system, a highly accurate and efficient transfer path analysis method was developed that does not require an excitation experiment.

  • PDF

Development of a Laboratory Test Device for the Performance Evaluation of Light-weight Impact Sound (경량충격음 성능 평가를 위한 실험실용 시험장치 개발)

  • 양수영;홍병국;송화영;김범수;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.505-508
    • /
    • 2004
  • 단열완충재 제품간의 경량충원 저감성능 평가를 객관적이고 신속하게 판별하기 위하여 실험실용 시험장치를 개발하였다. EVA계열 및 EPPㆍEPS계열의 단열완충재들에 대한 경량충격원 시험에서 제품간의 성능비교가 가능하였으며, 동탄성계수 및 손실계수 측정과 병행함으로써 제품들간의 우열성을 보다 정밀하게 평가할 수 있었다.

  • PDF

The Study of Improvement of the Void Slab Applying the Impedance Method (임피던스법을 이용한 보이드 슬라브의 개선방안에 관한 연구)

  • 오재응;김영식
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.276-284
    • /
    • 2001
  • In apartment buildings, floor-impact sound has been regarded as the major source that causes complaints from residents. It is mainly due to the use of light-weight structures and the lack of researches in terms of floor-impact sound. The purposes of this study are analyzing the characteristics of vibration response and sound radiation of 12type void slabs in the improvements void slab by impedance method and finding the fittest improvements void slab on the 12type void slab. The main results of this study are summarized as below: (1) In the $\frac{1}{3}$ octave band level of sound radiation, $\frac{1}{3}$ octave band levels, measured from four-divided improvement void slab(No.8) and eight-divided improvement void slab(No.12), are 10~25 dB lower than that of standard void slab(No.1) in the 1250 Hz. Especially, eight-divided improvement void slab(No.12) is the best void slab in terms of radiation efficiency of sound level. (2) In the correlation relation of acceleration and sound radiation, standard void slab(No.1), four-divided improvement void slab(No.8), SK standard four-hole void slab(No.10), and eight-divided improvement void slab(No.12) are positive correlation relation.

  • PDF

Application of Finite Element Method to Floor Impact Vibration Analysis in the Apartment Buildings (공동주택의 바닥 충격 진동 해석을 위한 유한요소법 응용)

  • Seo, Sang-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.387-390
    • /
    • 2005
  • Finite element method was applied to the vibration analysis of concrete slab system in apartment building. To save the time and cost the 2 dimensional finite element model was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Second, there is linear relationship between the impact sound pressure level and vibration acceleration level. Third, 2 dimensional finite element model was enough to analyze the vibration analysis of floor structure system.

  • PDF