• Title/Summary/Keyword: Acceleration Signal

Search Result 444, Processing Time 0.027 seconds

Transmission Control Method of Beacon Signal Based on Bluetooth of Lower Electric Power (저 전력 블루투스 기반 비콘 신호 전송 제어 방법)

  • Oh, Am-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1136-1141
    • /
    • 2016
  • IoT technology has been used as a core technology of convergence service that needs intelligent information processing, and the importance is largely emerging now. And internal network construction thru IoT interaction device can connect with IoT device effectively, provide diverse services by connection with open platform. Especially, beacon that is based on low electric power bluetooth device is receiving attention as one of core technology of IoT. Beacon technology is utilized widly in various fields of industry, and there are lot of demands in the specific environment and conditions beyond the basic function. On this thesis, the authors are proposing the beacon device that utilized acceleration sensor and hole sensor. this beacon device can control the target on specific situation thru sensing of moving target. For the more, we will expect to apply to the various type of factory environments like detachable installation, optimized management using sensor.

A Study on the Optimal Operation of Satellite Range Measurement for KOMPSAT II (다목적실용 위성 2호의 위성 거리 측정 최적 운용 방안 연구)

  • Kim, Young-Wan;Ahn, Sang-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2010
  • Based on the analyses of satellite range measurement, the optimal operation for satellite range measurement of KOMPSAT II, which operates in the low-earth orbit, was proposed in this paper. The orbital motion of the satellite was analyzed in viewpoints of radial velocity, acceleration and speed of acceleration. Correspondingly the effects for satellite ranging signal due to satellite motion were analyzed in viewpoints of doppler phenomena, which are doppler frequency, doppler rate and speed of doppler rate. The accuracy and ambiguity probability of the satellite range measurement were quantitatively analyzed under various circumstances. The optimal operation parameters for satellite range measurement were also analyzed based on the analyzed results. The analyzed results in this paper can be utilized in design of small-sized ground station for satellite range measurement.

Development of the off-vertical rotatory chair and visual stimulation system for evaluation of the vestibular function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • 김규겸;고종선;박병림;김인동
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.325-332
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement, It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission. Detailed data was described.

  • PDF

Development of CNC controller based on i80486 and 32bit DSP chip (i80486과 32비트 DSP를 사용한 CNC 제어기의 개발)

  • Kim, Dong-Il;Song, Jin-Il;Kim, Sung-Kwan;Lee, Choong-Hwan;Lee, Yun-Suk;Kang, Moon;Na, Sang-Keun;Lim, Yong-Gyu;Nam, Ki-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.537-540
    • /
    • 1992
  • This paper presents Samsung CNC (Computer Numerical Controller) system with an intel 80486/487 as the main CPU and a 32 bit floating point DSP(Digital Signal Processor) TMS320C30 as the motion control CPU. The Samsung CNC system diverse user-frienly characteristics such as multi-tasking, powerful menu system, internal PLC system, and 2/3 dimensional graphics in wire and solid mode. The main CPU executes central processing program, user interface program, interpreter, BMI, etc while the motion control CPU carries out some interpolations, acceleration/deceleration, and PID control algorithm with feedforward terms. Complex interpolations except linear and circular ones are performed on the main control CPU. The experimental results for the circular interpolation under linear acceleration/deceleration shows that the proposed CNC system can be widely used in controlling machining centers with good machining accuracy.

  • PDF

Error Correction of Real-time Situation Recognition using Smart Device (스마트 기기를 이용한 실시간 상황인식의 오차 보정)

  • Kim, Tae Ho;Suh, Dong Hyeok;Yoon, Shin Sook;Ryu, KeunHo
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1779-1785
    • /
    • 2018
  • In this paper, we propose an error correction method to improve the accuracy of human activity recognition using sensor event data obtained by smart devices such as wearable and smartphone. In the context awareness through the smart device, errors inevitably occur in sensing the necessary context information due to the characteristics of the device, which degrades the prediction performance. In order to solve this problem, we apply Kalman filter's error correction algorithm to compensate the signal values obtained from 3-axis acceleration sensor of smart device. As a result, it was possible to effectively eliminate the error generated in the process of the data which is detected and reported by the 3-axis acceleration sensor constituting the time series data through the Kalman filter. It is expected that this research will improve the performance of the real-time context-aware system to be developed in the future.

Design and Implementation of a Prediction System for Cardiovascular Diseases using PPG (PPG를 이용한 심혈관 질환 예측 시스템의 설계 및 구현)

  • Song, Je-Min;Jin, Gye-Hwan;Seo, Sung-Bo;Park, Jeong-Seok;Lee, Sang-Bock;Ryu, Keun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • Photoplethysmogram(PPG) is the method to obtain the biomedical signal using the linear relationships between the blood volume for changing the cardiac contraction and relaxation and the amount of light for absorbing the hemoglobin in the blood. In this paper, we proposed the analyzed results which show the heart rate variability and the distribution of heart rate for before and after using PPG. Moreover, this paper designed and implemented the system based on personal computer to predict cardiovascular disease in advance using the analyzed results for the autonomic balance from taking the spectral analysis of heart rate and the state of the blood vessel for analyzing APG(acceleration plethysmogram).

Comparison of Motion Sensor Systems for Gait Phase Detection (보행주기 검출용 모션 센서 시스템의 비교)

  • Park, Sun-Woo;Sohn, Ryang-Hee;Ryu, Ki-Hong;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

DEVELOPMENT OF MATDYMO(MULTI-AGENT FOR TRAFFIC SIMULATION WITH VEHICLE DYNAMICS MODEL) II: DEVELOPMENT OF VEHICLE AND DRIVER AGENT

  • Cho, K.Y.;Kwon, S.J.;Suh, M.W.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.145-154
    • /
    • 2006
  • In the companion paper, the composition and structure of the MATDYMO (Multi-Agent for Traffic Simulation with Vehicle Dynamic Model) were proposed. MATDYMO consists of the road management system, the vehicle motion control system, the driver management system, and the integration control system. Among these systems, the road management system and the integration control system were discussed In the companion paper. In this paper, the vehicle motion control system and the driver management system are discussed. The driver management system constructs the driver agent capable of having different driving styles ranging from slow and careful driving to fast and aggressive driving through the yielding index and passing index. According to these indices, the agents pass or yield their lane for other vehicles; the driver management system constructs the vehicle agents capable of representing the physical vehicle itself. A vehicle agent shows its behavior according to its dynamic characteristics. The vehicle agent contains the nonlinear subcomponents of engine, torque converter, automatic transmission, and wheels. The simulation is conducted for an interrupted flow model and its results are verified by comparison with the results from a commercial software, TRANSYT-7F. The interrupted flow model simulation is implemented for three cases. The first case analyzes the agents' behaviors in the interrupted flow model and it confirms that the agent's behavior could characterize the diversity of human behavior and vehicle well through every rule and communication frameworks. The second case analyzes the traffic signals changed at different intervals and as the acceleration rate changed. The third case analyzes the effects of the traffic signals and traffic volume. The results of these analyses showed that the change of the traffic state was closely related with the vehicle acceleration rate, traffic volume, and the traffic signal interval between intersections. These simulations confirmed that MATDYMO can represent the real traffic condition of the interrupted flow model. At the current stage of development, MATDYMO shows great promise and has significant implications on future traffic state forecasting research.

A Study on TTX Traction Characteristics using Measurement System (계측시스템을 활용한 틸팅열차 추진장치 특성 연구)

  • Han, Young-Jae;Lee, Su-Gil;Park, Choon-Soo;Han, Seong-Ho;Lee, Jun-Seok;Jung, Kwon-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1093-1098
    • /
    • 2007
  • Tilting trains are currently in operation in 13 countries around the world. With the advances in tilting technology, verification of economic efficiency, and changes in economic situations, the introduction of tilting trains will rapidly spread across the globe. The measurement system is composed of the industrial computers installed in the console and the measurement racks mounted on each car. It is utilized to accumulate the data by the communication card and the optical cable. The optical cable and power cable are coupled at the connector located in joint of train to make easy to disconnect car each other. The signal conditioner is designed to choose and to extend the channel for each sensor readily. The sensor measurement rack has adopted as decentralization method. It is installed in each car to minimize the cable length. In also, it is manufactured based on 19"rack and covered to protect the cable. In this study, the programs for measurement and analysis were also developed to understand the traction system characteristics of TTX. Using this measurement system, we studied that acceleration test, re-powering test, and gradually powering test. The acceleration performance of TTX is 1.735 km/h/s, and it is inner standard value. The notch test result from 1 to 7 steps, DC link voltage is under standard value, and the output electric current of inverter is controlled normally. From the test results, we saw the performances of the traction systems are normal.

A Pilot Study on the Muscle Activities in Step Input Test as an Indicator of the Vehicle Characteristics

  • Kong, Yong-Ku;Jung, Myung-Chul;Lee, In-Seok;Hyun, Young-Jin;Kim, Chang-Su;Seo, Min-Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.217-227
    • /
    • 2013
  • Objective: The purpose of this study was to analyze 'response time', 'peak response time' and 'overshoot value' for each muscle by applying the EMG signal to the vehicle response in ISO 7401 and to quantify the response of the driver according to vehicle characteristics by comparing vehicle characteristics and muscle responses of the driver. Background: The Open-loop test defined in international standards ISO 7401 is the only method for evaluating the performance of the vehicle. However, this test was focused only on mechanical responses, not driver's ones. Method: One skilled male driver(22 yrs. experience) was participated in this experiment to measure muscle activities of the driver in transient state. Then the seven muscle signals were applied to calculate 'response time', 'peak response time', and 'overshoot value'. Results: In the analyses of the EMG data, the effects of vehicle type and muscle were statistically significant on the 'response time' and 'peak response time'. Also, the effects of vehicle type, muscle, and lateral acceleration level were statistically significant on the 'overshoot value' in this study. According to the analyses of the vehicle motion data, vehicle motion variable(LatAcc, Roll, YawVel) was statistically significant on the 'response time' and vehicle type, vehicle motion variable, and lateral acceleration level were statistically significant on the 'peak response time', respectively. Conclusion: In the analyses of the 'response time' and 'overshoot value', the data of muscle activities(EMGs) was better index that could evaluate the vehicle characteristic and performance than the data of vehicle motion. In case of peak response time, both EMG and vehicle motion data were good index. Application: The EMGs data from a driver might be applicable as index for evaluation of various vehicle performances based on this study.