• 제목/요약/키워드: Accelerated Deterioration Test

검색결과 118건 처리시간 0.03초

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

장기폭로시험과 촉진시험에 근거한 염화물 함유량에 따른 철근콘크리트의 내구특성 (Durability Characteristics of RC containing Different Chloride Contents based on Long Term Exposure Test and Accelerated Test)

  • 권성준;송하원;신수철;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.759-762
    • /
    • 1999
  • The concrete structures possessing good structural integrity can face durability problems due to deteriorations of concrete structures under various environmental conditions. The durability problems weaken the structural integrity in the long run. Especially, the excessive use of sea sand causes serious reinforcement corrosion and carbonation in concrete structures. An accelerated test is often used to predict deterioration as a qualitative measure, but without long term exposure test results or understanding of the relationship between the accelerated test and the long term exposure test, the accelerated test result alone can not be used effectively as a quantitative measure. In this paper, a methodology is proposed to predict the long term deteriorations, based on the result of the short-term accelerated test, of concrete containing different contents of chloride ions. Then, the correlation between two results on the steel corrosion ratio and the carbonation depth is analyzed for concrete with different chloride contents.

  • PDF

동결융해 작용을 받는 콘크리트 구조물의 내구성능 저하 예측 방법에 관한 연구 (A Study on the Deterioration Prediction Method of Concrete Structures Subjected to Cyclic Freezing and Thawing)

  • 고경택;김도겸;조명석;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.131-140
    • /
    • 2001
  • In general, the deterioration induced by the freezing and thawing cyclic in concrete structures often leads to the reduction in concrete durability by the cracking or surface spalling. If it can prediction of concrete deterioration subjected to cyclic freezing and thawing, we can rationally do the design of mix proportion in view of concrete durability and the maintenance management of concrete structures. Therefore in this study a prediction method of deterioration for concrete structures subjected to the irregular freezing and thawing is proposed from the results of accelerated laboratory freezing and thawing test using the constant temperature condition and the in-situ weathering data. Furthermore, to accurately predict the concrete deterioration, a method of modification for the effect of hydration increasing during rapid freezing and thawing test is investigated.

  • PDF

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

공기압 실린더 가속시험 조건에 대한 연구 (Study on the Accelerated Test Condition of Pneumatic Cylinder)

  • 강보식;김형의
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1648-1651
    • /
    • 2007
  • The goal of this paper is to introduce two methods to determine a model for the accelerated factor equation for pneumatic cylinder according to the Black equation shape. The loads consist of working pressure and temperature and we adjust these two parameters to reduce the test time but keeping the true behavior of deterioration. The first part will introduce a method using accelerated factor coming from experimental results to determine the coefficient of the Black equation by the method of the least square theory. The second part will introduce another method based on various conditions of test with the assumption that the effect of temperature and the effect of pressure on the life of pneumatic cylinder are independent. In these two cases, the results are the unknown coefficients of the Black equation.

  • PDF

가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구 (A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test)

  • 강신동;김재호
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

알루미나계 자기애자의 장기 피로특성에 관한 연구 (Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System)

  • 한세원;조한구;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

동결융해작용을 받는 콘크리트의 열화예측에 관한 연구 (Study on the Prediction of Concrete Deterioration Subjected to Cyclic Freezing and Thawing)

  • 고경택;이종석;이장화;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.795-798
    • /
    • 1999
  • Deterioration induced by the freezing and thawing in concrete often leads to the reduction in concrete durability by the cracking or surface spalling. In this paper, the deterioration prediction model for concrete structures subjected to the irregular freeze-thaw was proposed from the results of accelerated laboratory test using the constant temperature condition and acceleration factor from the in-situ weather data.

  • PDF

부식촉진 실험을 통한 대기환경에서 신설 도장계의 노화곡선 제안 (Suggestion of Deterioration Curve for New-type Coating on Atmospheric Environment by Acceleration Corrosion Test)

  • 정영수;김민정;전석현;안진희;김인태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.75-83
    • /
    • 2019
  • 본 연구에서는 국내에서 사용되고 있는 우레탄계, 세라믹계, 폴리실록산계 및 불소수지계 강교량용 도장계를 대상으로 실내 부식실험을 실시하여 도장계별 노화모델을 도출하였다. 상도를 구분하여 각 도장계별로 시험편을 제작하였으며, 직경 0.5, 1, 3, 5 mm의 원형 결함을 도입하였다. ISO 20340를 이용하여 극한환경을 모사한 부식촉진실험을 실시하였다. 도장계별 노화곡선은 원형결함의 노화면적을 기준으로 평가되었다. 노화곡선을 사용하여 공용중인 강교의 도장 사용수명을 평가하기 위하여 촉진배율을 산출하였으며, 촉진배율은 ISO 20340과 ISO 9223의 대기환경 부식속도를 기준으로 산출되었다. 실험결과, 노화진전속도는 원형결함의 크기와 상관없이 증가하였으며, 노화면적이 3%일 때 우레탄 도장계의 노화수명은 C2, C3, C4 및 C5 등급에서 약 31.8, 15.8, 9.9 및 3.9년으로 평가되었다.

인공해수촉진열화시험에 의한 해양콘크리트의 내염특성에 관한 연구 (A Study on the Chloride Attack Resistance of Marine Concrete by Accelerated Deterioration Test of Artificial Seawater)

  • 이준;서정필;조성현;배준영;박상준;김경민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.357-358
    • /
    • 2010
  • 본 연구는 인공해수촉진열화시험에 의한 해양콘크리트의 내염특성 규명을 위한 연구의 일환으로서 시멘트 종류 및 도막처리에 따른 콘크리트의 특성을 분석하였으며, 시험 결과 강도 및 염소이온침투 특성 등을 고려할 경우 해양용 혼합시멘트가 콘크리트의 내염성능 개선에 효과적인 것으로 나타났다.

  • PDF