• Title/Summary/Keyword: Ac.I.

Search Result 678, Processing Time 0.027 seconds

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Clinical and Radiological Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocations and Distal Clavicle Fractures

  • Oh, Joo Han;Min, Seunggi;Jung, Jae Wook;Kim, Hee-June;Kim, Jae Yoon;Chung, Seok Won;Kim, Joon Yub;Yoon, Jong Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the clinical outcomes and complications of hook plate fixation in acromioclavicular (AC) joint dislocations and distal clavicle fractures. Methods: We retrospectively reviewed a series of 60 consecutive patients with hook plate fixation for AC joint dislocation (group I) and distal clavicle fracture (group II). Groups I and II had 39 and 21 patients, respectively. Clinical results were evaluated using the pain visual analogue scale (VAS), simple shoulder test, and Constant-Murley scores. In addition, subacromial erosion and stiffness were evaluated as complications. Results: At the removal, the pain VAS was $2.69{\pm}1.30$ and $4.10{\pm}2.14$ in groups I and II, respectively, which were significantly different (p=0.003). The simple shoulder test score was $9.59{\pm}1.60$ and $7.81{\pm}2.67$ in groups I and II, respectively, which were also significantly different (p=0.002). Subacromial erosion was significantly more frequent in group II (14/21 patients, 66.7%) than in group I (15/39 patients, 38.5%) (p=0.037), and stiffness was also higher in group II (17/21 patients, 81.0%) than in group I (22/39 patients, 56.4%), but it was not significant. Conclusions: Hook plate fixation showed good clinical and functional results for the treatment of acute unstable AC joint dislocation and distal clavicle fracture. But, in distal clavicle fractures, there are more subacromial erosion and stiffness compare with acute unstable AC joint dislocation.

Development and Performance test of Mechanical Support Equipment for Assebmly/Integration of KSLV-I (KSLV-I 총조립용 기계지원장비 개발 및 성능시험)

  • Jin, Seung-Bo;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.116-124
    • /
    • 2010
  • Ground complex composed of Assembly Complex(AC) and Launch Complex(LC) which is located on Oenarodo space center in Kohung is necessary for successful launching of KSLV-I. AC performs accepting of a KSLV-I 1st stage and 2nd stage, stage assembly, the integrated launch vehicle, the checked out, and all kinds of performance test, pre-launch tests and processing. At AC, the mechanical support equipments, that is called the technological equipments, are installed in the Launch Vehicle Assembly Test Building(LVATB). These technological equipments have diverse forms of an interface with mechanical/electric device of the launch vehicle and have to provide a condition and the performance guarantee of an optimum in the launching operation process. In this paper, the requirements specification and manufacturing performance test for the mechanical support equipments which are used in the assembly/disassembly and test of the launch vehicle are introduced.

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

Association between the Polymorphism in FUT1 Gene and the Resistance to PWD and ED in Three Pig Breeds

  • Luo, Yanru;Qiu, Xiaotian;Li, Hejun;Zhang, Qin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.10
    • /
    • pp.1268-1275
    • /
    • 2010
  • Post-weaning diarrhoea (PWD) and oedema disease (ED) caused by E. coli F18 always result in economic losses to pig producers, and no effective methods of controlling PWD and ED are presently available. FUT1 has been identified as a candidate gene controlling the expression of E. coli F18 receptor. This study examined the correlation between F18ab and F18ac adhesion phenotypes and the polymorphism at position M307 of the FUT1 gene in three pig breeds (231 Large White, 107 Landrace and 109 Songliao Black). The results showed: i) Both the susceptible genotypes (GG and GA) and the adhesion phenotypes (adhesive or weekly adhesive) were dominant in all three breeds with frequencies over 95%. ii) Three adhesion patterns of the two F18 variants F18ab and F18ac, i.e., ($ab^+$, $ac^+$), ($ab^+$, $ac^-$) and ($ab^-$, $ac^-$), were found in all three breeds, and there was no significant difference in the distribution of adhesion phenotypes of the two variants (separately or jointly) among the three breeds (p>0.05). iii) The FUT1 M307 genotypes were completely associated with the F18ab adhesion phenotypes and very strongly associated with the F18ac adhesion phenotypes. All individuals of genotype AA were non-adhesive to both F18ab and F18ac. All individuals of genotype GG or GA were adhesive to F18ab, whereas 11% of them were non-adhesive to F18ac. These results suggest that the polymorphism at FUT1 M307 can be used for marker-assisted selection of PWD and ED resistant pigs.

Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents (임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성)

  • Lee, Bok-Hee;Cho, Sung-Chul;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.

Cytotoxicity Test of Pokeweed Antiviral Protein Type I Gene by Using Yeast Expression System (효모 발현 시스템을 이용 PAP(Pokeweed Antiviral Protein) 유전자의 세포독성 연구)

  • 김선원;박성원;강신웅;이영기;이종철;최순용;이청호
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.2
    • /
    • pp.133-140
    • /
    • 2001
  • PAP-I cDNA was synthesized from total RNA of Phytolacca americana leaves by RT-PCR, and then subcloned to recombinant vector pBluescript II SK-. Using PCR with primers designed in our laboratory, we could get the 9 deletion mutant PAP-I cDNA fragments. The first of the fragments was deleted by 66bp from immature N-terminal and then the rest were deleted by 90bp sequentially. Sequentially deletion mutant PAP-I cDNAs were inserted to pAc55M, on down-stream of gall promoter. Recombinant pAc55M was transformed to yeast cells, psy1 and the cells were spreaded on SC_urn-/glucose plate media. Colonies on SC_ura-/glucose plate were streaked on the same position of SC_ura-/glucose and SC_ura-/galactose plate, and we selected colonies growing on both plates, which carry non-cytotoxic deleted mutant PAP-I cDNA. We selected 4 deletion mutant PAP-I cDNAs which have not cytotoxicity.

  • PDF

Wall Voltage Characteristics Simulated Using an Equivalent Circuit Model for AC POPs

  • Kim, Joon-Yub;Lim, Jong-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.317-320
    • /
    • 2003
  • As a convenient means for the characterization of the wall voltage and wall charge of AC PDPs during the sustain period, an equivalent circuit model for AC PDPs is presented. The equivalent circuit model for AC PDPs consists of capacitors and thyristors. The equivalent circuit model is based on the physical structure of the AC PDP and the I-V characteristic of the discharge space. This equivalent circuit model can be easily implemented in the standard simulators such as SPICE and can easily simulate the variation of the current, charge and voltage involved in AC PDPs as the supply voltage varies.

  • PDF

Effect of [EMIM]Ac Recycling on Salix gracilistyla Miq. Pretreatment for Enzymatic Saccharification

  • HAN, Song-Yi;PARK, Chan-Woo;KWON, Gu-Joong;KIM, Jong-Ho;KIM, Nam-Hun;LEE, Seung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.405-413
    • /
    • 2020
  • Recycling of ionic liquid (1-ethyl-3-methylimidazolium acetate, [EMIM]Ac) after the pretreatment of Salix gracilistyla Miq. was conducted and the effect of the recycling number on the enzymatic saccharification yield was investigated. Enzymatic saccharification was performed using an enzyme cocktail (Acremonium cellulase and Optimash BG) at 50 ℃ for 72 h. All recycled [EMIM]Ac samples showed a lower amount of water soluble fraction than pure [EMIM]Ac. On increasing the recycling number from 1 to 4, the amount of water soluble fraction decreased from 18% to 15%. The X-ray diffraction pattern of the products pretreated with recycled [EMIM]Ac showed cellulose I crystalline polymorph. The crystallinity of the product pretreated with recycled [EMIM]Ac was 47-49%, which was lower than 33% of that with pure [EMIM]Ac. The yields of glucose and xylose decreased in the pretreatment with recycled [EMIM]Ac compared to that with pure [EMIM]Ac.

Effect of Two-step Surface Modification of Activated Carbon on the Adsorption Characteristics of Metal Ions in Wastewater I. Equilibrium and Batch Adsorptions

  • Park, Geun-Il;Lee, Jae-Kwang;Ryu, Seung-Kon;Kim, Joon-Hyung
    • Carbon letters
    • /
    • v.3 no.4
    • /
    • pp.219-225
    • /
    • 2002
  • The two-step surface modifications of activated carbon was carried out to improve the adsorption capacity of toxic heavy metal ions in liquid phase. Physical and chemical properties of the as-received activated carbon (AC) and two kinds of surface-modified activated carbons ($1^{st}AC$ and $2^{nd}AC$) were evaluated through the BET analysis, surface acidity, and oxides measurements. Specific surface area and pore volume did not significantly change, but surface oxide-group remarkably increased by the surface modification. Equilibrium and batch adsorptions of the various metals, such as Pb, Cd, and Cr, using AC, $1^{st}AC$, and $2^{nd}AC$ were performed at initial pH 5. The adsorption capacity and rate of $2^{nd}AC$ were higher than those of AC and $1^{st}AC$. The carboxylic/sodium carboxylate complex groups were developed from the two-step surface modification of activated carbon, which strongly affected the adsorption of metal ions.

  • PDF