• Title/Summary/Keyword: Ac magnetic susceptibility

Search Result 22, Processing Time 0.022 seconds

Design of a Sensitive ac Magnetic Susceptibility

  • D. K. Oh;Lee, Cheol-Eui;J.I. Jin;S. J. Noh
    • Journal of Magnetics
    • /
    • v.2 no.2
    • /
    • pp.55-57
    • /
    • 1997
  • A mutual-inductance bridge type ac magnetic susceptibility measurement system was built in our laboratory. With addition of a phase-sensitive prestage, it was simple to implement and provided a high signal-to-noise (S/N) ratio.

  • PDF

Magnetic Field Dependence of Brownian Motion in Iron-oxide Nanoparticles (산화철 나노입자의 브라운 운동에 대한 자기장 의존성 연구)

  • Jung, Eun Kyung;Yoon, Seok Soo;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.13-18
    • /
    • 2016
  • The ac magnetic susceptibility was measured in iron-oxide nanoparticles with average size of 26 nm, which were uniformly dispersed in organic solvent. The ac magnetic susceptibility measured under zero magnetic fields was well fitted with Debye relaxation model and the relaxation frequency was 370 Hz. The relaxation frequency of the nanoparticles coincided with relaxation time of the Brownian motion, which is due to the viscosity of the liquid medium in which magnetic nanoparticles dwell. The Brown relaxation frequencies were linearly increased with magnetic field.

Substrate-free Biosensing using Brownian Rotation of Bio-conjugated Magnetic Nanoparticles

  • Chung Seok-Hwan;Hoffmann Axel;Chen, Liaohai;Sun, Shouheng;Guslienko Konstantin;Grimsditch Marcos;Bader Samuel D.
    • Journal of Magnetics
    • /
    • v.11 no.4
    • /
    • pp.189-194
    • /
    • 2006
  • The recent development of bio-conjugated magnetic nanoparticles offers many opportunities for applications in the field of biomedicine. In particular, the use of magnetic nanoparticles for biosensing has generated widespread research efforts following the progress of various magnetic field sensors. Here we demonstrate substrate-free biosensing approaches based on the Brownian rotation of ferromagnetic nanoparticles suspended in liquids. The signal transduction is through the measurement of the magnetic ac susceptibility as a function of frequency, whose peak position changes due to the modification of the hydrodynamic radius of bio-conjugated magnetic nanoparticles upon binding to target bio-molecules. The advantage of this approach includes its relative simplicity and integrity compared to methods that use substrate-based stray-field detectors.

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

AC susceptibility of current-carrying iron whiskers : Effect of current variation (전류에 의한 철단결정의 교류 자기감수율 : 전류 변화에 의한 효과 )

  • Jae-Gwang Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.179-184
    • /
    • 1995
  • The ac magnetic susceptibility of {100} iron whiskers as a function of currents is studied with and without external field. The ac susceptibility depends on the magnitude and the direction of the applied dc current when a small external field is applied along the magnetization of the central domain of the whisker. Variation of the central domain size accounts for the current-dependent response. The measured magnetic responses are explained, using a micromagnetic calculation based on a simple model, as a function of applied currents over a wide range except critical values.

  • PDF

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)

DYNAMICAL MAGNETIC PROPERTIES OF IRON-NITRIDE MAGNETIC FLUIDS

  • Mamiya, H.;Nakatani, I.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.815-818
    • /
    • 1995
  • Ac susceptibility of iron-nitride magnetic fluids with various particle number densities was measured. Therelaxation time increases rapidly as the temperature decreases or the inter-particle interaction increases. The analysis of the data suggests that the activation energy is proportional to ${(k_{B}T/J_{typ})}^{\alpha}$ with $\alpha$~-0.24 in the lower temperature range in which the thermal energy is comparable to the magnetic dipole interaction.

  • PDF

Standardization of the Critical Temperature Measurement by Using an AC Susceptometer

  • Lee, K. W.;Kim, M. S.;Kim, K.;Kim, D. H.;Lee, S. G.
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.22-27
    • /
    • 2005
  • We have studied the standardization of critical temperature measurements by using an ac susceptometer. Wire forms of NbTi, $Nb_{3}Sn$, and Bi-2223 superconductors were prepared to measure the temperature dependences of the magnetization. In order to study the optimum ac magnetic field and frequency, various amplitudes from 2 Oe to 10 Oe with frequencies from 11.3 Hz to 1033 Hz were applied to three specimens. Analytical comparison of the magnetic curves with the resistive curves was accomplished to investigate validity of using the new method.

  • PDF

Current Carrying Iron Whiskers: A New Magnetic Configuration

  • Lee, J.G.;Arrott, A.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.372-375
    • /
    • 1995
  • The magnetization pattern of the central cross section deduced from the ac susceptibility measurement is described with an analytical function. The function is based on a charge-free configuration. The thickness of the $^{\circ}$ wall lying in a (100) plane and the wall energy are calculated analytically. Total energy of the domain structure has been minimized with Ritz's method. As the result of the minimization, the energy density of the $^{\circ}$ wall lying in a (100) plane is $0.58\;erg/cm^{2}$ and the one for a (110) plane is $1.18\;erg/cm^{2}$. Thicknesses of these walls are calculated numerically. Also, the calculation indicates there is a small central domain at the cross section without applied current. With the ac susceptibility measurement the existence of the domain without current can be identified.

  • PDF