• Title/Summary/Keyword: Absorption system

Search Result 2,011, Processing Time 0.027 seconds

Degradation of Monoethanolamine during Continuous Operation of a Laboratory Scale CO2 Absorption System (실험실 규모 이산화탄소 흡수장치의 연속운전시 모노에탄올아민 열화 특성)

  • Kang, Ji-A;Woo, Wongu;Lim, Ho-Jin
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.385-393
    • /
    • 2016
  • Oxidative and thermal degradation of alkanolamines for a promising $CO_2$ capture technology of absorption might cause decrease in $CO_2$ capture efficiency and formation of hazardous byproducts. In this study, characteristics of a representative absorbent of monoehtanolamine (MEA) were examined for a long term operation using a laboratory scale absorption system. An $CO_2$ absorption system with ID 56 mm and absorption zone height 100 cm was developed for the characterization. Absorption solution of 30 wt% MEA was circulated at 100 mL/min to treat air with 15% $CO_2$ and 1 ppm NO at 10 L/min. Temperatures of absorber and stripper were maintained at $40^{\circ}C$ and $120^{\circ}C$, respectively. For the course of 5 weeks continuous operation, MEA concentration was decreased approximately by 70% and $CO_2$ removal efficiency was dropped from 95% to 65%. Ionic byproducts of $NH_4{^+}$, $NO_2{^-}$, and $NO_3{^-}$ were accumulated up to 48 g/mL, 0.2 g/mL, and 1.5 g/mL, respectively, tracking the variation of MEA concentration. Formation of various organic byproducts were also observed.

The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System (TDLAS 시스템을 이용한 유해 배기가스의 농도 계측)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Chun, Kwang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Efficiency Analysis of a Wave Power Generation System by Using Multibody Dynamics (다물체동역학을 이용한 다자유도 파력발전시스템의 흡수 효율 분석)

  • Kim, Min Soo;Sohn, Jeong Hyun;Kim, Jung Hee;Sung, Yong Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.557-563
    • /
    • 2016
  • The energy absorption efficiency of a wave power generation system is calculated as the ratio of the wave power to the power of the system. Because absorption efficiency depends on the dynamic behavior of the wave power generation system, a dynamic analysis of the wave power generation system is required to estimate the energy absorption efficiency of the system. In this study, a dynamic analysis of the wave power generation system under wave loads is performed to estimate the energy absorption efficiency. RecurDyn is employed to carry out the dynamic analysis of the system, and the Morison equation is used for the wave load model. According to the results, the lower the wave height and the shorter the period, the higher is the absorption efficiency of the system.

The Characteristics of Heating Performance on Small Sized Ammonia Absorption System (소형 암모니아 흡수식 냉난방기의 난방성능 특성)

  • Jin, Byoung-Ju;Oh, Seung-Taek;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Sim-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.120-123
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

The Characteristics of Heating Performance on Small Sized Ammonia Absorption System (소형 암모니아 흡수식 냉난방기의 냉방성능 특성)

  • Jin, Byoung-Ju;Oh, Seung-Taek;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Sim-Won;Kyung, Ick-Soo;Erickson, Donald C
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.198-202
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

A Study on the Sound Absorptive Characteristics and Performance of Parallel Perforated Plate Systems (병렬 다공판 시스템의 흡음특성과 성능에 관한 연구)

  • Hong, Byung-Kuk;Song, Hwa-Young;Seo, Seong-Won;Lee, Dong-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1003-1008
    • /
    • 2005
  • The acoustic absorption of a multiple layer perforated plate system is very good near the resonance frequency region, while it has been regarded as a demerit that its frequency bandwidth is considerably narrow. In order to overcome such a demerit, the parallel perforated plates with different porosities are proposed. The sound absorption of such system composed of a parallel perforated plate is calculated by an equivalent electroatoustic circuit approach and validated by comparing the calculated absorption coefficients with those measured by the two-microphone impedance tube method. The sound absorptive characteristics and performance of parallel perforated plate systems are discussed from a standpoint of frequency bandwidth related with sound absorption.

Solar Absorption System Analysis with Spreadsheet Models (태양열 이용 흡수식 냉난방시스템의 스프레드쉬트 모델)

  • Choi, Hong-Kyu;Fazzolari, Rocco A.
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 1992
  • An hourly simulation model of a solar LiBr-water absorption cooling and heating system (for brevity, solar absorption system) is presented, based on SuperCalc spreadsheet computational procedures. This paper demonstrates the value of using spreadsheet simulation techniques by examining the thermal performances of a solar absorption system. The hourly heating and cooling coil loads for a typical office building in Tucson, Arizona are modeled and calculated using ASHRAE methods. The details of the algorithms for the components and control schemes are presented. Two case studies are also presented using real system parameters.

  • PDF

Study on the Interaction between Curcumin and Ethylamines by Absorption and Fluorescence Spectroscopic Techniques

  • Kim, Sung Hoon;Gwon, Seon Yeong;Lee, Eun-Mi;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.27 no.4
    • /
    • pp.340-344
    • /
    • 2015
  • The interaction between curcumin(1,7-bis[4-hydroxy-3-methoxyphenyl]-1,6-heptadiene-3,5-dione) and ethylamines was studied in DMSO:$H_2O$(5:1, v/v) using absorption and fluorescence measurements. The association constant, $K_{ass}$, and the Stern-Volmer constants were calculated by the Benesi-Hildebrand and Stern-Volmer equation, respectively. Curcumin displayed marked UV-Vis absorption changes and highly responsive fluorescence quenching in the presence of ethylamine and the quenching ability was enhanced almost linearly with the concentration of ethylamines. The apparent Stern-Volmer constant measured for the ethylamine-curcumin system was about 1000-fold greater than that of the triethylamine-curcumin system, indicating considerably greater quenching efficiency of ethylamines.

Cycle Analysis of Diffusion Absorption Refrigerator (확산형 흡수식 냉장고의 사이클 해석)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system (공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향)

  • Kim, S.C.;Oh, M.D.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF