• 제목/요약/키워드: Absorption refrigeration

검색결과 228건 처리시간 0.025초

LiBr/$H_2O$계 흉수기의 흡수촉진에 관한 실험적 연구 (Experimental investigation of enhanced heat and mass transfer toy LiBr/$H_2O$ absorber)

  • 설원실;권오경;윤정인
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.581-588
    • /
    • 1998
  • An experimental study of the absorption process of water vapor into Lithium Bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and floral tube for the absorber of absorption chiller-heaters. floral tube has higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chiller -heaters.

  • PDF

금속와이어 흡음재의 흡음성능에 관한 실험적 연구 (An Experimental Study on the Absorption Performance of Steel-Wire Sound Absorbing Materials)

  • 서성원;용호택;이동훈
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.413-421
    • /
    • 2003
  • The acoustic performances of steel-wire sound absorbing materials with different thicknesses and bulk densities were investigated experimentally. The well-known two-cavity method was used to measure the characteristic impedance, propagation constant and absorption coefficient. The normal absorption coefficients measured by two-cavity method agreed well with those by the two-microphone impedance tube method. The experimental results showed that the magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the steel-wire. Therefore, the steel-wires obtained from the crushed tire chips could be used as a good absorbing material.

용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험 (Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate)

  • 문춘근;방기석;김재돌;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

Numerical Simulation of Solution Droplets and Falling Films in Horizontal Tube Absorbers

  • Phan Thanh-Tong;Lee Ho-Saeng;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.597-607
    • /
    • 2006
  • This paper presents a numerical simulation of the behavior of the LiBr solution droplets and falling films in horizontal tube banks of absorber. The model developed here accounts for the details of the droplets formation and impact process for absorption on horizontal tubes including the heat transfer from solution film to the tube wall. Especially. the characteristic of unsteady behavior of solution flow has been investigated. Flow visualization studies shown that the solution droplets and falling films have some of the complex characteristics. It is found that. with the numerical conditions similar to the operating condition of an actual absorption chiller/heater, the outlet solution temperature and heat flux from solution film to the tube wall have a stable periodic behavior with time. The solution droplets and falling films in horizontal tube banks of absorber is a periodic unsteady flow. The results from this model are compared with previous experimental observation taken with a high-speed digital video camera and shown good agreement.

최속 강하법을 이용한 흡수식 냉동공조시스템 제어 (Control of the Absorption Air Conditioning System by Using Steepest Descent Method)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.495-501
    • /
    • 2003
  • Control algorithms for the absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. The simulation results showed energy savings and the effective controls of an absorption air conditioning system.

수직흡수기의 열 및 물질전달 촉진 (Enhancement of Heat and Mass Transfer for a Vertical Type Absorber)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.362-370
    • /
    • 1998
  • Absorption systems require a heat source for working but they have a great merit in that relatively low-temperature and low-quality types of thermal energy such as solar heat and exhaust heat can be effectively utilized as heat source. However details research related to absorbers which have a great effect on performances has been rarely done and thus there has been a strong hope for positive developments to improve their efficiencies. This paper describes absorption experiments made with different inside tube diameters and shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a water/LiBr solution flowing down an absorber of vertical inner tubes. As a result absorption acceleration tube compares bare tube and heat transfer improved by order of insert spring tube corrugated tube grooved tube. And the acceleration that is good provided in inserting spring tube for both sides of heat and mass transfer.

  • PDF

플레이트-휜형 흡수기의 흡수성능에 대한 연구 (The Study on Absorption Performance of a Plate-Fin Type Absorber)

  • 강인석;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

수냉형 직렬방식 2중효용 흡수식 냉방기의 열해석과 최적 설계 (Thermal Analysis and Optimum Design of Water-Cooled, Series-Flow Type, Double-Effect Absorption Heat Pump)

  • 오명도;김영률;김선창;김영인
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.332-341
    • /
    • 1992
  • An absorption heat pump cycle has been modeled and simulated to analyze the system performance of water-cooled, series-flow, double-effect absorption heat pump, which can be applied to a direct gas fired cooling system with the medium range of cooling capacity (15RT level). Effect of absorption cooling system parameters, such as concentration difference, inlet temperature of cooling water, 1st generator temperature, leaving temperature differences of condenser and evaporator and efficiency of solution heat exchanger, has been investigated in the view of system cooling performance.

  • PDF

하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션 (Simulation of a two-stage absorption heat pump cycle using treated sewage)

  • 이용화;신현준;최국광
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

LiBr용액량 변화에 따른 수평다관 흡수기의 특성 연구 (An investigation of absorption phenomena in the horizontal staggered tube absorber for various LiBr solution flow rates)

  • 권율;윤상국
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.332-338
    • /
    • 1999
  • An experimental study of absorption phenomena of water vapor into LiBr solution was carried out to find out the optimum solution flow rate. The staggered bundle of horizontal absorption tubes, which are the same configuration as the commercial heat pump, were tested. The results showed that the heat transfer and absorption rate were enhanced with the increase of LiBr solution flow rate. Those values for different absorber pressures showed the same qualitative trends. The optimum flow rate of solution was obtained as three times of the designed flow rate.

  • PDF