• 제목/요약/키워드: Absorption performance

검색결과 1,481건 처리시간 0.028초

박사르®정 4 밀리그램(라시디핀 4 mg)에 대한 라니디엠®정 4 밀리그램의 생물학적동등성 (Bioequivalence of LANIDIEM® Tablet 4 mg to Vaxar® Tablet 4 mg(Lacidipine 4 mg))

  • 이윤영;김혜진;나숙희;조경희;장문선;박영준;이희주
    • Journal of Pharmaceutical Investigation
    • /
    • 제40권2호
    • /
    • pp.125-131
    • /
    • 2010
  • A bioequivalence study of LANIDIEM$^{(R)}$ tablet 4 mg (Samil. Co., Ltd.) to Vaxar$^{(R)}$ tablet 4 mg (GlaxoSmithKline Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Forty healthy male Korean volunteers were enrolled in the study and thirty six volunteers completed the study according to the protocol. Thirty six volunteers received each medicine at the lacidipine dose of 4 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of lacidipine were monitored by a high performance liquid chromatography - tandem mass spectrometry (LC-MS/MS) for over a period of 24 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for LANIDIEM$^{(R)}$/Vaxar$^{(R)}$ were log 0.8102~log 1.0417 and log 0.8493~log 1.1439, respectively. These values were within the acceptable bioequivalence intervals of log 0.80~log 1.25. Thus, our study demonstrated the bioequivalence of LANIDIEM$^{(R)}$ tablet 4 mg and Vaxar$^{(R)}$ tablet 4 mg with respect to the rate and extent of absorption.

활성화된 플라이애쉬 혼입콘크리트의 철근부식거동에 관한 전기화학적 연구 (Electrochemical Studies on the Corrosion Performance of Steel Embeded in Activated Fly Ash Blended Concrete)

  • 송하원;이창홍;이근주;벨루사라스와티
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.97-108
    • /
    • 2008
  • 시멘트 대체 재료로서 플라이애쉬의 사용은 시멘트 생산비용을 절감시키는 효과를 창출하였다. 반면에 플라이애쉬 혼입콘크리트는 OPC에 비해 상대적으로 긴 양생시간과 초기강도의 발현 저하를 들 수 있어 이의 해결을 위해 물리적 방법, 온도 및 화학적 방법 등과 같은 다양한 활성화 기술의 적용을 통하여 플라이애쉬 혼입 콘크리트의 수화를 가속시킬 수 있고, 콘크리트의 부식 저항성을 향상시킬 수가 있다. 본 연구에서는 10~40%의 치환률을 가진 활성화된 플라이애쉬 시편을 통해 개방 회로형 전위측정(Open circuit potential measurement)을 수행하였고, 투수시험, 급속염화물침투시험 및 SEM(Scanning electron microscopy)촬영을 통해 OPC 콘크리트와 비교 분석 하였다. 또한, 치환률의 임계범위 20~30%의 경우에 있어서 활성화된 플라이애쉬를 사용한 콘크리트가 열화저항성에 있어서 개선효과가 나타나고 있음을 확인하였다. 또한 플라이애쉬를 화학적으로 활성화시킨 경우가 본 연구에서 수행된 다른 활성화 방법들에 비해 더욱 좋은 결과를 나타나고 있음도 확인하였다.

다류소재 식물류 중의 황산화물질 함량 분석 (Determination of Antioxidants Contents in Various Plants Used as Tea Materials)

  • 김미혜;김명철;박종석;박은지;이종옥
    • 한국식품과학회지
    • /
    • 제31권2호
    • /
    • pp.273-279
    • /
    • 1999
  • 국내외에서 재배, 유통되고 있는 다류소재 식물류 40종에 대하여 총 페놀성 물질과 비타민 C 함량은 비색법으로, ${\alpha}-tocopherol$${\beta}-carotene$ 함량은 HPLC에 의해, 셀레늄 함량은 원자흡광법을 이용하여 분석하였다. 시료 100 g당(건량) 들어있는 총 페놀성 물질 함량은 녹차잎, 홍차잎, 우롱차잎, 인스탄트커피 등이 약 7g으로 가장 높았고 셀레늄 함량은 산수유와 칡이 약 $4{\mu}g$으로 가장 높았다. ${\beta}-carotene$ 함량은 두충$(8587{\mu}g)$, 감잎$(6222{\mu}g)$, 녹차잎$(3652{\mu}g)$ 등이 매우 높았다. ${\alpha}-tocopherol$ 함량은 감잎(33 mg), 두충(26 mg), 녹차잎(16 mg), 홍차잎(13 mg) 순으로 높았으며, 비타민 C 함량은 녹차잎(199 mg)과 홍차잎(117 mg)이 가장 높았다.

  • PDF

지하 콘크리트구조물의 열화 억제에 의한 내구성 증진에 관한 연구 (A Study on the Durability Improvement by Controlling the Deterioration of Underground Concrete Structures)

  • 천병식;최춘식;정원우
    • 한국지반공학회논문집
    • /
    • 제20권3호
    • /
    • pp.23-31
    • /
    • 2004
  • 일반적으로 코팅은 철근 콘크리트를 보호하기 위해 사용되어지며, 이러한 목적으로 사용되어지는 코팅에는 무기계 뿐만 아니라 유기계 코팅이 있다. 무기계 코팅의 장점은 자외선 흡수성이 적고 불연성이라는 것이며, 반면 유기계 코형의 장점은 $CO_2, SO_2$투과성 및 물의 투수성이 낮으며, 철근 콘크리트의 보호능력은 유기계 코팅이 더 우수하다. 그러나 에폭시, 우레탄 및 아크릴과 같은 유기계 코팅은 콘크리트와의 열팽창계수와 탄성계수 차이로 인해 장기 접착강도가 저하되고, 통기성이 부족하여 형성된 막에 들뜸이 발생된다. 또한 유기계 코팅이 콘크러트의 습윤면에 적용될 경우에는 접착의 문제가 발생된다. 본 연구에서는 콘크리트를 보호하기 위해 폴리머와 세라믹을 합성시켜 개발된 코팅제의 물리 성능과 내구 성능 및 용출 안전성에 대한 시험을 하였다. 개발된 코팅계에 대하여 유기계 코팅재 및 에폭시와 비교하였으며, 시험결과 개발된 코팅재는 콘크리트를 보호하기 위한 유기계 코팅재에 비해 성능이 떨어지지 않았고, 반면 용출 안전성 측면에서는 에폭시보다 더 우수함을 보였다. 특히 물과 접해 있는 지하 콘크리트구조물을 보호하는 데에 적합하며, 무기계와 유기계 코팅재의 장점을 갖은 콘크리트 보호용 코팅재라고 판단된다.

광원에 따른 수종의 치면열구전색제로부터 용리되는 모노머에 관한 연구 (A STUDY OF MONOMER RELEASE FROM PIT AND FISSURE SEALANTS ACCORDING TO VARIOUS LIGHT SOURCES)

  • 서현우;박호원
    • 대한소아치과학회지
    • /
    • 제32권2호
    • /
    • pp.284-292
    • /
    • 2005
  • 본 연구에서는 치과용 복합레진의 중합률에 영향을 미치는 다양한 광원인 할로겐, 플라즈마, LED를 사용하여 임상에서 사용하는 여러 치면열구전색제들을 중합 시, 이로부터 용리되는 미반응 모노머들을 확인하고 정량화하고자 하였다. 5가지의 광중합형 치면열구전색제를 각각의 광원에 따라 중합한 시편을 제작하여 3차 증류수에 넣은 후 바로 용리시킨 액을 0시간으로 하고 $37^{\circ}C$ 항온수조에서 10분, 1시간, 12시간, 24시간 보관한 후 각각의 용리액을 고성능 액체 크로마토그래피를 이용하여 미반응 모노머의 정성 및 정량 분석을 시행하였고, 다음과 같은 결과를 얻었다. 1. 표준 모노머들의 분리시간은 BPA 2.3분, TEGDMA 3.2분, UDMA 5.6분, Bis-GMA 6.5분, Bis-DMA 10.4분이었다. 2. 모든 치면열구전색제에서 TEGDMA를 제외한 어떠한 모노머들도 용리되지 않았다. 3. 저장 12시간까지 대부분의 TEGDMA가 용리되었으며, 이후부터는 그 양이 현저히 줄어드는 양상을 보였다. 4. 최소권장중합 시간인 할로겐 20초, 플라즈마 3초, LED 10초 중합 시 TEGDMA의 용리량은 할로겐, LED, 플라즈마 순으로 적었다. 5. 모든 중합기에서 Pit & Fissure $Sealant^{TM}$의 용리량이 가장 적었으며, 할로겐 중합시 $Helioseal^{(R)}$ F가, 플라즈마 아크중합 시 $Concise^{TM}$가, LED 중합 시 $Teethmate^{(R)}$ F-1이 가장 많은 용리량을 보였다.

  • PDF

압력순환흡착법과 다공성 매체 연소법을 이용한 전자산업 불화가스 저감 스크러버 개발 (The Development of Scrubber for F-gas Reduction from Electronic Industry Using Pressure Swing Adsorption Method and Porous Media Combustion Method)

  • 정종국;이기용;이상곤;이은미;모선희;이대근;김승곤
    • 청정기술
    • /
    • 제23권2호
    • /
    • pp.181-187
    • /
    • 2017
  • 반도체 및 디스플레이 산업에서 배출되는 과불화합물은 연소, 열, 플라즈마, 촉매 등의 다양한 방법이 적용된 스크러버에 의해 분해 과정을 거친 후 배출되나, 운영 스크러버의 대부분이 과도한 에너지의 사용, 낮은 저감 효율을 보임으로써 이러한 단점의 극복이 요구된다. 압력순환흡착법과 다공성 매체 연소법의 두 가지 기술이 연계된 새로운 형태의 과불화합물 저감 스크러버를 개발하고 특성을 알아보았다. 분해 대상인 $CF_4$의 흡착비와 손실계수는 흡착 컬럼의 입구와 출구에서 농도 측정을 통해 계산하였으며, 연소기의 입구와 출구의 유량과 농도 측정을 통해 처리 효율을 계산하였다. 기존 스크러버와의 에너지 사용량 및 처리효율 비교를 위하여 다양한 유량에 대한 성능 평가가 진행되었다. 1412 ppm, 204 LPM의 $CF_4$가 유입된 흡착 컬럼에서의 흡착비는 1.65였으며, 유입되는 $CF_4$의 손실 계수는 8.2%였다. 이때 연소기로 유입되는 $CF_4$의 유량과 농도는 각각 91 LPM과 2335 ppm이었으며, $CF_4$ 19 LPM, $O_2$ 40 LPM을 사용한 연소 반응시 약 96%의 저감 효율을 나타내었다. 상용 스크러버와의 동일 운전 조건에서의 다공성 매체 연소에서의 $CF_4$ 저감 효율과 전체 에너지 사용 효율 비교시 각각 16%, 41% 이상의 저감 효율 상승과 에너지 절감 효과를 보였다.

Adhesion of Model Molecules to Metallic Surfaces, the Implications for Corrosion Protection

  • de Wit, J.H.W.;van den Brand, J.;de Wit, F.M.;Mol, J.M.C.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.50-60
    • /
    • 2008
  • The majority of the described experimental results deal with relatively pure aluminium. Variations were made in the pretreatment of the aluminum substrates and an investigation was performed on the resulting changes in oxide layer composition and chemistry. Subsequently, the bonding behavior of the surfaces was investigated by using model adhesion molecules. These molecules were chosen to represent the bonding functionality of an organic polymer. They were applied onto the pretreated surfaces as a monolayer and the bonding behavior was studied using infrared reflection absorption spectroscopy. A direct and clear relation was found between the hydroxyl fraction on the oxide surfaces and the amount of molecules that subsequently bonded to the surface. Moreover, it was found that most bonds between the oxide surface and organic functional groups are not stable in the presence of water. The best performance was obtained using molecules, which are capable of chemisorption with the oxide surface. Finally, it was found that freshly prepared relatively pure aluminum substrates, which are left in air, rapidly lose their bonding capacity towards organic functional groups. This can be attributed to the adsorption of contamination and water to the oxide surface. In addition the adhesion of a typical epoxy-coated aluminum system was investigated during exposure to water at different temperatures. The coating was found to quite rapidly lose its adhesion upon exposure to water. This rapid loss of adhesion corresponds well with the data where it was demonstrated that the studied epoxy coating only bonds through physisorptive hydrogen bonding, these bonds not being stable in the presence of water. After the initial loss the adhesion of the coating was however found to recover again and even exceeded the adhesion prior to exposure. The improvement could be ascribed to the growth of a thin oxyhydroxide layer on the aluminum substrate, which forms a new, water-stable and stronger bond with the epoxy coating. Two routes for improvement of adhesion are finally decribed including an interphasial polymeric thin layer and a treatment in boiling water of the substrate before coating takes place. The adhesion properties were finely also studied as a function of the Mg content of the alloys. It was shown that an enrichment of Mg in the oxide could take place when Mg containing alloys are heat-treated. It is expected that for these alloys the (hydr)oxide fraction also depends on the pre-treatment and on the distribution of magnesium as compared to the aluminium hydroxides, with a direct impact on adhesive properties.

Fabrication and Catalysis of $SiO_2$-Coated Ag@Au Nanoboxes

  • 이재원;장두전
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.588-588
    • /
    • 2013
  • Nanoscale noble-metals have attracted enormous attention from researchers in various fields of study because of their unusual optical properties as well as novel chemical properties. They have possible uses in diverse applications such as devices, transistors, optoelectronics, information storages, and energy converters. It is well-known that nanoparticles of noble-metals such as silver and gold show strong absorption bands in the visible region due to their surface-plasmon oscillation modes of conductive electrons. Silver nanocubes stand out from various types of Silver nanostructures (e.g., spheres, rods, bars, belts, and wires) due to their superior performance in a range of applications involvinglocalized surface plasmon resonance, surface-enhanced Raman scattering, and biosensing. In addition, extensive efforts have been devoted to the investigation of Gold-based nanocomposites to achieve high catalytic performances and utilization efficiencies. Furthermore, as the catalytic reactivity of Silver nanostructures depends highly on their morphology, hollow Gold nanoparticles having void interiors may offer additional catalytic advantages due to their increased surface areas. Especially, hollow nanospheres possess structurally tunable features such as shell thickness, interior cavity size, and chemical composition, leading to relatively high surface areas, low densities, and reduced costs compared with their solid counterparts. Thus, hollow-structured noblemetal nanoparticles can be applied to nanometer-sized chemical reactors, efficient catalysts, energy-storage media, and small containers to encapsulate multi-functional active materials. Silver nanocubes dispersed in water have been transformed into Ag@Au nanoboxes, which show highly enhanced catalytic properties, by adding $HAuCl_4$. By using this concept, $SiO_2$-coated Ag@Au nanoboxes have been synthesized via galvanic replacement of $SiO_2$-coated Ag nanocubes. They have lower catalytic ability but more stability than Ag@Au nanoboxes do. Thus, they could be recycled. $SiO_2$-coated Ag@Au nanoboxes have been found to catalyze the degradation of 4-nitrophenol efficiently in the presence of $NaBH_4$. By changing the amount of the added noble metal salt to control the molar ratio Au to Ag, we could tune the catalytic properties of the nanostructures in the reduction of the dyes. The catalytic ability of $SiO_2$-coated Ag@Au nanoboxes has been found to be much more efficient than $SiO_2$-coated Ag nanocubes. Catalytic performances were affected noteworthily by the metals, sizes, and shapes of noble-metal nanostructures.

  • PDF

고투과성 세라믹 중공사 개발과 접촉막 공정의 CH4/CO2 분리 특성 평가 (Development of High-Permeability Ceramic Hollow Fiber and Evaluation of CH4/CO2 Separation Characteristics of Membrane Contactor Process)

  • 이승환;김민광;정병준;장학룡;박정훈
    • 멤브레인
    • /
    • 제30권4호
    • /
    • pp.269-275
    • /
    • 2020
  • 본 연구에서는 세라믹 중공사 접촉막 모듈을 이용하여 CH4/CO2 혼합가스에서 CO2 분리 실험을 수행하였다. 높은 성능의 접촉막 모듈을 제작하기 위해 고투과성 중공사막의 제조 실험을 진행하였으며, 제조한 중공사막은 N2 기체투과실험을 통해 투과 성능을 평가하였다. 최종적으로 고투과도 중공사막을 이용하여 CH4/CO2 혼합 기체 분리를 위한 Hollow fiber membrane contactor (HFMC)를 제작하였다. 실험에는 CH4/CO2 혼합 기체(34.5% CO2, CH4 balance)와 monoethanolamine (MEA)를 사용하였으며, CO2 제거 효율이 흡수제의 유량에 따라 어떠한 영향을 받는지 평가하였다. CO2 제거 효율은 액체유량이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 결과를 보였다.

루리드 정(록시스로마이신 150 mg)에 대한 록시스린 정의 생물학적동등성 (Bioequivalence of RoxithrinTM Tablet to RulidTM Tablet (Roxithromycin 150 mg))

  • 정선경;이윤영;조태섭;김호현;이예리;이경률;이희주
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권3호
    • /
    • pp.209-214
    • /
    • 2004
  • A bioequivalence study of $Roxithrin^{TM}$ tablet (Kukje Pharma. Ind. Co., Ltd.) to $Rulid^{TM}$ tablet (Han Dok Pharma. Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the roxithromycin dose of 300 mg in a $2{\times}2$ crossover study. There was a one-week wash-out period between the doses. Plasma concentrations of roxithromycin were monitored by a high-performance liquid chromatography for over a period of 36 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 36 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the cross-over design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Roxithrin^{TM}/Rulid^{TM}$ were 1.00 - 1.13 and 0.98 - 1.10, respectively. These values were within the acceptable bioequivalence intervals of 0.80 - 1.25. Thus, our study demonstrated the bioequivalence of $Roxithrin^{TM}$ and $Rulid^{TM}$ with respect to the rate and extent of absorption.