• 제목/요약/키워드: Absorption air condition

검색결과 118건 처리시간 0.032초

증기압축식/흡수식 하이브리드 히트펌프 사이클에 관한 최적화 연구 (Optimization Study of the Compression/Absorption Hybrid Heat Pump Cycle)

  • 전관택;박춘건;정동수
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.48-58
    • /
    • 2001
  • For the past few decades the vapor compression cycle with a solution circuit (VCCSC) has been known to provide high efficiency and variable capacity. In this study performance of a VCCSC cycle is examined through computer simulation. In the simulation heat exchangers were modelled by specifying UA or effectiveness values while the compressor performance was specified by an isentropic efficiency. Aqua/ammonia solution was chosen as the working fluid which can be used in the high temperature range. The results show that there exists an optimum operation condition which is dependent upon the temperatures of the external heat transfer fluids(HTFs). Besides the HTF\`s temperature, the maximum system pressure and the size of the solution heat exchanger are shown to have an influence on the optimum operation condition. Finally, as compared to a simple vapor compression heat pump with HFC134a, the COP of the VCCSC is shown to be 2∼22% higher.

  • PDF

공랭형 수직원관 흡수기에서의 열 및 물질전달 해석 (Analysis of heat and mass transfer in a vertical tube absorber cooled by air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3293-3303
    • /
    • 1996
  • Numerical analyses have been performed to estimate the absorption heat and mass transfer coefficients in absorption process of the LiBr aqueous solution and the total heat and mass transfer rates in a vertical tube absorber which is coolING ed by air. Axisymmetric cylindrical coordinate system was adopted to model the circular tube and the transport equations were solved by the finite volume method. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by water vapor in tube. Effects of film Reynolds number on heat and mass transfer coefficients have been also investigated. Especially, effects of tube diameter have been considered to observe the total heat and mass transfer rates through falling film along the tube. Based on the analysis it has been found that the total mass transfer rate increases rapidly in a region with low film Reynolds number(10 ~ 40) as the film Reynolds number increases, while decreases beyond that region. The total heat and mass transfer rates increase with increasing the tube diameter.

Numerical Simulation of Solution Droplets and Falling Films in Horizontal Tube Absorbers

  • Phan Thanh-Tong;Lee Ho-Saeng;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.597-607
    • /
    • 2006
  • This paper presents a numerical simulation of the behavior of the LiBr solution droplets and falling films in horizontal tube banks of absorber. The model developed here accounts for the details of the droplets formation and impact process for absorption on horizontal tubes including the heat transfer from solution film to the tube wall. Especially. the characteristic of unsteady behavior of solution flow has been investigated. Flow visualization studies shown that the solution droplets and falling films have some of the complex characteristics. It is found that. with the numerical conditions similar to the operating condition of an actual absorption chiller/heater, the outlet solution temperature and heat flux from solution film to the tube wall have a stable periodic behavior with time. The solution droplets and falling films in horizontal tube banks of absorber is a periodic unsteady flow. The results from this model are compared with previous experimental observation taken with a high-speed digital video camera and shown good agreement.

수음실 잔향 시간변화에 따른 바닥충격음레벨 특성 - 잔향실을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in a Reverberation Chamber)

  • 정정호;김정욱;정재군
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.274-281
    • /
    • 2013
  • Field measurement method of heavy/soft impact sound pressure level which is regulated in JIS and ISO has been using in Korea, Japan and Canada. It is reported that heavy/soft impact sound pressure level was varied by the sound field condition of receiving room such as sound absorption power and room volume. In this study, it is checked that heavy/soft impact sound pressure level was affected by the receiving sound field condition. Rubber ball and bang machine sound pressure level was measured in the vertically connected reverberation chamber. In oder to check the effect of receiving sound field on heavy/soft impact sound pressure, sound absorption power was changed with polyester sound absorption blankets with air space and glass wool. The reverberation time at 1 kHz band was changed from 10 s to 0.2 s by sound absorption material. Rubber ball sound pressure level measured without sound absorption material was 58 dB in $L_{i,Fmax,AW}$, but the level was 46 dB with sound absorption treatment. From this result, it is confirmed that sound field correction method is needed in the heavy/soft impact sound pressure level measurement method using bang machine and rubber ball.

공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향 (Influence of surfactant on heat transfer of air-cooled vertical absorber)

  • 윤정인;권오경;문춘근
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

기저귀용 부직포의 촉감에 미치는 마찰과 함수의 영향 (Effect of Abrasion and Absorption on the Handle of Nonwovens for disposable diaper)

  • 홍경화;강태진;오경화
    • 한국의류학회지
    • /
    • 제28권1호
    • /
    • pp.112-118
    • /
    • 2004
  • Recently, as the percentage of women employment has been growing, the demand for various facilities and services regarding household duties and infant rearing is increasing and so do the amount of the disposable diaper used. Among the components of disposable diaper, the top sheet contacting with infant skin directly is usually made with nonwoven textiles. Therefore, the mechanical and surface characteristics of the nonwovens used in disposable diaper are important for the skin health of infants. In this study, we have explored the mechanical and surface properties, such as friction coefficient, fluid permeability and strength, of the nonwovens used for disposable diaper top sheet and observed the variation of their properties with abrasion cycles. Nonwoven materials examined in this study are 100% cotton spunlace, 100% tencel spunlace, 100% polypropylene (PP) thermal bonding and 100% PP air through (Thru-air bonded carded web). From the result of KES-F analysis, we've found that 100% PP air through type nonwoven had a low friction coefficient and showed a little change in surface properties as increasing abrasion cycles. Moreover, it revealed superior fluid permeability and quick-drying character. On the other hand, though showing an excellent absorption force, the spun lace type nonwoven made of 100% cotton and 100% tencel displayed relatively low abrasion strength especially in wetting condition.

경남 김해지역의 동계 대기중 중금속 분포와 특성 (Study on the Distribution and Characteristics of Heavy Metals in Ambient Air of Kimhae, Kyongnam of Wintertime)

  • 정성욱;전병일
    • 한국환경과학회지
    • /
    • 제5권4호
    • /
    • pp.453-462
    • /
    • 1996
  • This study was conducted to evaluate the level of atmospheric heavy metals and the relationship of that concentration with weather conditions. This research monitored the concentration of Total Suspended Particulates (TSP) at every three hours by using High Volume Air Sampler from December 24th, of 1995 to Febuary 20th, 1996 in Kimhae area, which recently became a rapidly growing residential and industrial sitc. The items such as air-temperature, relative humidity, radition, wind speed, and wind direction were monitored by using Atmospheric Weather System at the same time. From the collected TSP, the concentration of heavy metals were analyzed by using the Atomic Absorption Spcetrophotometry. The mean concentration of TSP was 110.4 $\mu\textrm{g}$/$m^3$, and the mean concentration of lead (Pb), copper(Cu), chromium (Cr), manganese (Mn), cadmium (Cd), were 0.837 $\mu\textrm{g}$/$m^3$, 0486 $\mu\textrm{g}$/$m^3$, 0.264$\mu\textrm{g}$/$m^3$). The concentration of Pb and Mn was higher in the moring and that of Cu, Cr and Cd was higher in the afternoon and the evening. Regarding the relationship between the concentration of pollutants and weather condition, the-concentration TSP revealed positive correlation with temperature, humidity, wind speed, but negative correlation with tradition (p<0.01). The concentration of Mn revealed positive correlation with temperature and humidity, but negative correlation with wind speed (p<0.01). And the the concentration of pollutants and weather condition revealed higher correlation within the same time period. In summary, the paralleled mornitoring of air conditions and weather condition should be recommended to. get the correct informations concerning the pollution and to prevent the deterioration of air conditions.

  • PDF

창호지의 흡음성능에 관한 실험적 연구 (Sound Absorption Performance of Korean Traditional Window Papers)

  • 최은석;이태강;김항;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2006
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to he standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound absorption characteristics according to difference in thickness and finishing method of window paper and those in sound absorption characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰 (Study on Improvement in Reliability of Analysis for VOCs and Aldehydes)

  • 이민도;이상욱;임용재;김영미;김소영;문광주;한진석;정일록
    • 한국대기환경학회지
    • /
    • 제22권4호
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향 (Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller)

  • 최경식;손화승;김형식;임상규;허광범
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.