• 제목/요약/키워드: Absorption Cooling System

검색결과 152건 처리시간 0.024초

A Cooled Deformable Bimorph Mirror for a High Power Laser

  • Lee Jun-Ho;Lee Young-Cheol;Kang Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • 제10권2호
    • /
    • pp.57-62
    • /
    • 2006
  • Adaptive optics (AO) has been applied in various fields including astronomy, ophthalmology and high power laser systems. An adaptive optics system for a high power laser is not significantly different from other AO systems in the point of configuration except that high energy absorbed by the deformable mirror distorts the deformable mirror surface and so degrades system performance. Currently we are researching a bimorph deformable mirror for beam cleaning of a high power class laser. The bimorph mirror was considered to have 99% reflective coating and 1% absorption. So this paper first presents the temperature profiles and corresponding thermal distortions of the bimorph mirror faceplate when the mirror is under a high power lasing for 10 seconds. The analysis was accomplished by the use of finite difference and finite element computer programs to generate the element arrays, calculate the temperature profiles, and determine the structural deformations. Then this paper proposes an 'embedded wafer' type water-cooling system with derived cooling parameters.

빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구 (The Novel Configuration for Building Energy System Including Build ins Microgrid)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로- (A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis -)

  • 김은섭;윤석환;박정강;전윤호;강혜원;김상혁;김지연;이용구;이동근
    • 한국환경복원기술학회지
    • /
    • 제24권6호
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.

가스냉방 보급효과에 대한 연구 (Study on The Supplying effect of Gas Air Conditioning Systems)

  • 한정옥;채정민;최경식;홍성호
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.19-25
    • /
    • 2011
  • 냉방용 에너지는 크게 전력과 가스로 대별할 수 있는데, 전기냉방 시스템은 하절기 최대전력을 상승시키는 요인이 되고 있다. 전기에너지는 수요 공급 특성상 저장이 불가능하기 때문에 예상되는 최대전력을 상회하는 공급능력을 보유해야 하며 매년 하절기의 사회문제로 대두되어 왔다. 한편 가스냉방의 경우 흡수식 시스템과 GHP 시스템이 있다. 그러나 가스냉방 보급용량은 전기 냉방에 비해 매우 적으며 소형시장은 대부분 전기냉방에 의존하고 있는 상황이다. 본 논문에서는 국내 냉방에너지 현황을 살펴보고 에너지원간의 부하분담 비중을 분석하여 냉방에너지의 합리적인 방향을 제시하고자 2024년까지 장기적인 가스냉방 보급 규모를 전망하였으며, 이를 바탕으로 가스냉방 보급효과를 분석하여 가스냉방의 확대 필요성을 뒷받침 하고자 하였다.

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

소형(小型)디젤기관(機關)의 냉각성능(冷却性能)에 관(關)한 연구(硏究) (Cooling Performance on the Small Diesel Engine)

  • 김성래;명병수
    • 농업과학연구
    • /
    • 제17권1호
    • /
    • pp.45-51
    • /
    • 1990
  • 본(本) 실험(實驗)은 동력경운기(動力耕耘機)에 탑재(搭載)되는 소형(小型)디젤기관(機關)의 냉각수(冷却水)의 적정량을 구명(究明)하기 위한 기초적(基礎的)인 실험(實驗)으로 냉각수(冷却水) 순환량(循環量) 15, 20, $25{\ell}/min$의 3수준(水準)으로, 변화(變化)시켰을 때의 기계손실(機械損失), 출력(出力), 연료소비율(燃料消費率), 토크, 냉각수흡열양(冷却水吸熱量), 열효율등(熱效率等)에 미치는 영향(影響)을 측정(測定) 분석(分析)한 결과(結果)는 다음과 같다. 1. 공시기(公試機)의 Motoring loss는 상용회전(常用回轉) 2,200rpm에서 1.371kW로 정격출력시(定格出力時)의 기계효율(機械效率)은 79.13%로 외국제품(外國製品)보다 약간(若干) 낮았다. 2. 냉각수(冷却水) 순환량(循環量)을 증가(增加)시킴에 따라 출력(出力)은 증가(增加)되는 경향(傾向)을 보였다. 3. 정격출력시(定格出力時) 연료소비율(燃料消費率)은 냉각수순환량(冷却水循環量) $20{\ell}/min$일때 282.93g/kW-h로서 가장 작게 나타났으며 이때 냉각수(冷却水)의 출구온도(出口溫度)는 $80.9^{\circ}C$이었다. 4. 냉각수(冷却水) 순환량(循環量)의 변화(變化)에 따른 토크의 변화(變化)는 거의 없었다. 5. 기관(機關)의 냉각수(冷却水) 흡열량(吸熱量)은 냉각수(冷却水) 순환량(循環量)의 증가(增加)에 따라 증가(增加)하는 경향(傾向)을 나타내었다. 6. 열효율(熱效率)은 냉각수(冷却水) 순환량(循環量) $20{\ell}/min$에서 32.31%로 가장 높게 나타났다.

  • PDF

선박배출 배기냉각과 흡수식이 결합된 하이브리드 시스템을 통한 물 회수 및 미세먼지 저감을 위한 기초실험연구 (Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships)

  • 김영민;신동길;류영현
    • 해양환경안전학회지
    • /
    • 제28권7호
    • /
    • pp.1252-1258
    • /
    • 2022
  • 선박용 엔진에서 배출되는 배기가스에는 다량의 수분과 미세먼지를 포함하고 있다. 미세먼지에는 여과성 미세먼지와 배기 배출 후 액상으로 변화하는 응축성 미세먼지가 포함되어 있으며 배출 전에 걸러지는 고체상 미세먼지보다 응축성 미세먼지가 더 많은 것으로 보고되고 있다. 본 연구에서는 배기가스의 배기열과 수분을 회수하고 응축성 미세먼지를 제거하기 위한 실험장치를 실험실 내의 가스보일러 배기가스를 이용하여 테스트 하였다. 배기가스는 1차적으로 냉각방식으로 수분과 응축성 미세먼지가 제거되고 2차적으로 흡수제 방식에 의해 추가적으로 수분이 제거되었다. 상대습도 측정에 의한 배기가스 수분 제거율을 계산하면 1단계 배기냉각 방식으로 73%, 2단계 흡수제 방식으로 90% 제거되는 것으로 측정되었다. 이 과정에서 응축성 미세먼지는 80~90% 제거되는 것으로 측정되었다. 개발 시스템에 의해 회수된 열은 공정열로 활용할 수 있으며, 회수된 물은 수처리 과정을 통해 공정수로 활용할 수 있다. 또한 현재 관리 규제가 되고 있지 않지만 미세먼지의 주요 원인인 응축성 미세먼지를 효과적으로 제거할 수 있을 것으로 기대된다.

반사판을 이용한 고정식 집속형 태양광.열복합패널의 성능평가 (Performance Evaluation of Fixed-concentrated Photovoltaic/Thermal Hybrid Panel using Reflector)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.85-92
    • /
    • 2005
  • One of the most effective methods for utilizing solar energy is to combine thermal solar and optical energy simultaneously using a hybrid panel. Many systems using various kinds of photovoltaic panels have already been constructed. But utilizing solar energy by means of a hybrid panel with concentrator has not been to be attempted yet. Normally if sunlight is directed on the solar cell, and there is no increase in temperature, the absorption energy of each cell will increase per unit area. In a silicon solar cell. however, cell conversion efficiency decreases according to the increasing temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. we design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect effectively thermal energy. We compared performance of new hybrid panel with PV module and thermal panel. We also evaluated conversion efficiency, electric power and thermal capacity and confirmed cooling effect from thermal absorption efficiency.

공기열원 히트 펌프 시스템 설계 (Design of Heat Pump System in Air Heat Source Type)

  • 이윤민;신진섭
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.73-77
    • /
    • 2019
  • 본 논문에서는 냉매의 흡열 또는 응축열을 이용하여 저온의 열원을 고온으로 전달하거나 고온의 열원을 저온으로 전달하는 공기열원 히트 시스템을 설계 제작하였다. 히트펌프는 냉동 사이클에서 응축기 및 증발기를 기능이 전환가능한 밸브를 이용하며 따라서 난방시에 응축기 기능을 하는 열교환기가 냉방시에는 증발기 기능을 하도록 함으로써 냉난방을 구현할 수 있도록 하였다. 이를 위하여 저온의 열원을 고온으로 전달하거나 고온의 열원을 저온으로 전달하기 위한 체계가 개발되었다. 실험을 위하여 냉각 사이클에서 콘덴서와 증발기를 전환하는 기능으로 밸브를 사용하기 위한 히트펌프를 제작하였다. 그 결과 히트펌프시스템은 공기열원방법으로 개발되어졌으며 하나의 시스템으로 냉난방을 동시에 해결할 수 있는 에너지 절약 시스템을 설계하였다.

하수처리수이용 신용액 흡수식 냉동기의 성능해석 (Performance Analysis of New Working Solution for Absorption Refrigeration Machine using Treated Sewage)

  • 권오경;유선일;윤정인
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.231-240
    • /
    • 1998
  • CFC계 냉매에 의한 지구환경문제 야기, 여름철 피크전력의 증가뿐만 아니라 열회수 시스템에서의 손실로 인하여 고성능 흡수냉동시스템의 개발은 이 문제를 해결할 수 있는 유망한 방법중의 하나이다. 하수처리수를 이용한 흡수식 냉동시스템은 환경보호와 에너지 보존의 측면에서 유용하다. 본 연구에서는 2중효용 병렬 및 직렬방식에 대한 사이클 시뮬레이션 해석을 수행하였다. 신작동매체로 LiBr+LiI+LiCl+LiNO3 용액을 선택하였다. 이 연구의 주된 목적은 흡수기와 응축기의 냉각수로써 하수처리수를 효과적으로 이용할 수 있는 가능성을 평가하는 것과 2중효용 병렬과 직렬방식에 영향을 미치는 신작동매체의 특성을 파악하고 최적설계조건을 찾고자 하는 것이다. 본 연구에서 사이클 시뮬레이션을 통하여 신작동매체를 사용하는 흡수식 냉동기의 특성을 파악했으며 이를 기존의 LiBr 수용액을 사용하는 흡수식 냉동기와 비교평가하였다. 신작동매체를 이용한 흡수식 냉동기는 LiBr 수용액을 사용하는 경우보다 COP의 향상과 시스템의 소형화가 가능하다는 것을 알 수 있었다.

  • PDF