• 제목/요약/키워드: Absorption

검색결과 13,365건 처리시간 0.037초

Sound Absorption Property of Heat-Treated Wood at A Low Temperature and Vacuum Conditions

  • Byeon, Hee-Seop;Park, Jung-Hwan;Hwang, Kyo-Kil;Park, Han-Min;Park, Beyung-Soo;Chong, Song-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권2호
    • /
    • pp.101-107
    • /
    • 2010
  • Heat treatment was performed to improve sound absorption properties for four tree species; Tulip tree, Korean Paulownia, Red pine and Costata birch, at temperature of $175^{\circ}C$ and $200^{\circ}C$under vacuum condition. Sound absorption properties of two kinds of boards, which were in radial and tangential sections, were measured under a frequency range of 100 to 3200 Hz by the two microphone transfer function method. It was found that sound absorption properties were increased by heat treatment and the efficiency was higher at $200^{\circ}C$ than that at $175^{\circ}C$. Even Costata birch had a little effect on low temperature of $175^{\circ}C$, $200^{\circ}C$ heat treatment for sound absorption property, the efficiencies of sound absorption were 14, 19%, respectively. The efficiencies of sound absorption ranged 22 to 120% for heat-treated Tulip tree, Korean Paulownia.

Studies on Drug Absorption Characteristics for Development of Ocular Dosage Forms: Ocular and Systemic Absorption of Topically Applied ${\beta}-Blockers$ in the Pigmented Rabbit

  • Lee, Yong-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권3호spc1호
    • /
    • pp.59-66
    • /
    • 1994
  • The objective of this study was to determine the influence of drug lipophilicity on the extent of ocular and systemic absorption following topical solution instillation in the pigmented rabbit. ${\beta}-Blockers$ of various lipophilicity were chosen as model drugs, $25\;{\mu}l$ of a 15 mM drug solution in isotonic pH 7.4 buffer was instilled, and ocular tissue and plasma drug concentrations were monitored. Ocular absorption was apparently increased in all eye tissues, but non-corneal absorption ratio was decreased by increasing of drug lipophilicity. Systemic bioavailability was ranged from 61% for atenolol to 100% for timolol, and at least 50% of the systemically absorbed drug reached the blood stream from the nasal mucosa. Occluding the nasolacrimal duct for 5 min reduced the extent of systemic absorption of timolol and levobunolol, but did not do so for atenolol and betaxolol. Taken together, the ocular absorption of topically applied ophthalmic drugs would be modest for lipophilic drugs. By contrast, the systemic bioavailability would be modest for drugs at the extremes of lipophilicity, and the nasal contribution to systemically absorbed drug diminished with increasing of drug lipophilicity.

  • PDF

An Experimental Study on the Absorption Property of Slit Absorbers with Composite Details

  • Jeong, Dae-Up;Joo, Moon-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • 제21권2E호
    • /
    • pp.81-90
    • /
    • 2002
  • Single absorbing materials and Helmholtz resonators have limited absorption characteristics over limited frequency ranges due to their structures and properties. Porous materials are highly absorptive for mid and high frequency ranges, while they have little sound absorption for low frequency sounds. Helmholtz resonators are generally used to absorb sound energy for a specified frequency range. Hence they have limited capability in controlling the overall acoustic properties of a space. Not much has been known about useful finishing materials which have enough rigidity and absorption over broad frequency range, in spite of wide demands from acoustic designers and consultants. The present work measured and analyzed absorption characteristics of a slit absorber by varying surface materials, depths of air gap, dimensions of slat and slit widths. It was found that the narrower the slit width, the larger the absorptions over the wide frequency ranges and the pattern was dependent on the presence of porous material. Narrower slat's width tend to increase the slit absorber's absorption more or less. Absorption coefficients at low frequency ranges were dramatically improved (from 0.23 to 0.56) by increasing air gap when porous materials were present.

실 단면 형상과 니트 구조 인자가 흡한속건 소재의 수분이동 특성에 미치는 영향 (Effect of Yarns Cross-Sections and Structure Parameters of Its Knitted Fabrics to Moisture Transport of Perspiration Absorption and Fast Dry Fabrics)

  • 김현아
    • 한국의류산업학회지
    • /
    • 제20권4호
    • /
    • pp.457-463
    • /
    • 2018
  • This study examined the water absorption and drying properties of the thirteen types of the knitted fabrics for sports wear. These physical properties were analysed with relation to the constituent fiber cross-sectional shape and structure parameters of the knitted fabrics by regression analysis. Absorption and drying properties of the knitted fabric specimens were increased with increasing the porosity of the constituent yarns, which was attributed to the capillary channels in the yarns. The water absorption and drying properties were increased and decreased with increasing tightness factor and stitch density of the knitted fabric. The absorption property of the knitted fabric for perspiration absorption and fast dry sport-wear clothing was mostly influenced mostly by fiber cross-sectional shape and its characteristics, whereas, drying property was dependent on the structural parameters of the knitted fabric such as tightness factor and stitch density. Therefore, superior perspiration absorption and fast drying knitted fabric could be obtained in the fabric structure with optimum tightness factor and stitch density, and constituent yarn structure with non-circular fiber crosssection and high porosity. GATS method and MMT method are used to measure sweating fast drying properties and it is necessary to carry out studies using these measurement methods in order to compare with the results of this study.

Effect of Carbonization Temperature on Hygric Performance of Carbonized Fiberboards

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.615-623
    • /
    • 2014
  • Increases of public attention on healthy environment lead to the regulation of indoor air quality such as Clean Healthy House Construction Standard. This standard covers emission of total volatile organic compounds (TVOCs) (e.g., formaldehyde, benzene, and toluene), ventilation, and use of environmentally-friendly products or functional products. Moisture absorption and desorption abilities are a recommended functionality for improving indoor air quality. In this study, moisture absorption and desorption capacities of carbonized board from wood-based panels and other materials were determined by using UNT-HEAT-01 according to ISO 24358:2008. Pine had higher moisture absorption and desorption capacities ($49.0g/m^2$ and $35.3g/m^2$, respectively) than hinoki cypress, cement board, gypsum board, oriented strand board, and medium density fiberboard (MDF). The moisture absorption and desorption capacities differed considerably according to the wood species. After carbonization process at $400^{\circ}C$, the absorption and desorption ability of MDF increased to 38% and 60%, respectively. However, moisture absorption and desorption capacities decreased with increasing carbonization temperature, but they were still higher than original MDF. Therefore, it is suggested that carbonization below $600^{\circ}C$ can improve moisture absorption/desorption capacities.

간섭계를 이용한 차량 기반 에어로졸 광흡수 측정 연구 (Study of Aerosol Light Absorption Measurement Operated in a Vehicle Using an Interferometer)

  • 이정훈
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1317-1324
    • /
    • 2011
  • 대기중에 부유하고 있는 입자들의 광흡수량을 측정할 수 있는 기법을 소개한다. 본 연구에서 사용된 기법은 광열분광법이다. 광흡수 측정에 있어서 광열 기법의 장점은 광산란에 둔감할 뿐만 아니라 광산란 계수의 영향을 받지 않고 광흡수 계수를 직접적으로 측정할 수 있다는 것이다. 공기중 부유물질의 흡수 계수 측정의 시간 상수는 10 초이며, 실시간으로 고속도로 주변에서 흡수 계수를 측정하였다. 자동차 경주용 트랙, 공항, 또는 연구소 정문 등 차량 통행량이 많은 지역에서의 흡수 계수가 높게 측정되었는데, 이는 카본 부유물 입자에 의한 영향이라고 판단된다.

Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지 (Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law)

  • 윤병동;장범찬;김희수;배용채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

Sebum Absorption Characteristics of Polymer Microgel-containing Face Powder

  • Lee, Young-Keun;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1396-1400
    • /
    • 2007
  • In this study, poly(iso-butyl methacrylate-co-ethylene glycol dimethacrylate) [poly(iso-BMA-co-EGDMA)] microgel was prepared and used as a face powder additive. The spreading, adhesiveness, and skin reactivity of poly(iso-BMA-co-EGDMA) microgel-containing face powder II were investigated and compared with the same properties of commercially available Silica bead 700-containing face powder I. In the results, the particle size of the poly(iso-BMA-co-EGDMA) microgel was significantly swelled as a result of sebum absorption. Face powder II showed a lower primary irritation index and a higher adhesiveness than did face powder I. Face powder I showed a low sebum absorption ratio and a relatively high rate of sebum absorption, whereas face powder II, contrastingly, exhibited a high sebum absorption ratio and a low rate of sebum absorption, which properties would reduce the phenomena of facial strain and sliminess. These results indicate that poly(iso- BMA-co-EGDMA) microgel has outstanding sebum absorption characteristic and adhesiveness, and thus that it is a good candidate for use as a face powder additive.

Enhancement of Absorption Performance Due to the Wavy Film of the Vertical Absorber Tube

  • Kim Jung-Kuk;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.41-48
    • /
    • 2006
  • Absorption performance at the vertical interface between refrigerant vapor and liquid solution of $LiBr-H_{2}O$ solution was enhanced by the waves formed due to the interfacial shear stress. The present study investigated experimentally and analytically the improvements of absorption performance in a falling film by wavy film flow. The dynamic parameter was the film Reynolds numbers ranged from 50 to 150. The energy and diffusion equations were solved simultaneously to find the temperature and concentration profiles at the interface of liquid solution and refrigerant vapor. Absorption characteristics due to heat and mass transfer were analyzed for the falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Absorption performance showed a peak value at the solution flow rate of $Re_{f}>100$. Absorption performance for the wavy film flow was found to be greater by approximately 10% than that for uniform film flow. Based on numerical and experimental results, the maximum absorption rate was obtained for the wavy flow caused by spring insert. The difference between the measured and the predicted results were ranged from 5.8 to 12%.

흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석 (Performance Analysis of Microturbine CHP System with Absorption Chiller)

  • 윤린;한승동
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.486-491
    • /
    • 2008
  • The performance of a microturbine CHP system equipped with an absorption chiller was analyzed by modeling it. The microturbine with recuperator was simulated with the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microturbine were simulated. These results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type with a solution heat exchanger. The heat input into the generator was proportional to the heat transfer rate and the UA values of the heat exchangers of the absorption chiller. Furthermore, the COP of the absorption chiller increased with respect to an increase of the heat input into the generator, under the sufficient evaporator capacity condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller doubled, and the UA values for evaporator and condenser increased by factors of x3.9 and x3.4, respectively, under the same COP condition.