• Title/Summary/Keyword: Absorbing capacity

Search Result 155, Processing Time 0.026 seconds

The Collapse Characteristics of Vehicle Thin-walled Members Coated Damping Material (댐핑재가 도포된 차체 박육부재의 압궤특성)

  • 송상기;박상규;송찬일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.76-81
    • /
    • 2003
  • The purpose of this study is to analyze the collapse characteristics of widely used spot welded section members coated damping material Y1000 and to develop an analysis method for acquiring exact collapse loads and energy absorption ratio. Hat-shaped thin-walled members have the biggest energy absorbing capacity in a front-end collision. The sections were tested on quasi-static and impact loads. Specimens with two type thickness, width ratio and spot weld pitch on the flange have been tested in impact velocities(6.73n0sec and 7.54n1sec) which imitate a real-life car collision. As a result, it was developed the system for acquiring impact energy absorbing characteristics of structure united thin-walled member and damping materials.

Seismic study of buildings with viscoelastic dampers

  • Pong, W.S.;Tsai, C.S.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.6
    • /
    • pp.569-581
    • /
    • 1995
  • In this paper, the seismic behavior of a 10-story building equipped with viscoelastic dampers is analyzed. The effects of ambient temperature, the thickness, the total area, and the position of the viscoelastic dampers are studied. Results indicate that the energy-absorbing capacity of viscoelastic damper decreases with increasing the ambient temperature. The thickness and the total area of viscoelastic dampers also affect the seismic mitigation capacity. The thickness cannot be too small, which is not effective in vibration reduction, nor can it be too large, which not only increases the cost but also reduces the seismic resistance. The total area of viscoelastic dampers should be determined properly for optimum damper performance at the most economical design. The mounting position of viscoelastic dampers also influences the structure's seismic performance. Numerical results show that, if properly equipped, the VE dampers can reduce the structural response both floor displacement and story shear force and increase the overall level of damping in structures during earthquakes.

A Study on the Collapse Characteristics of Thin-walled Structural Members for Automobiles Under Axial Compression Load (차체구조용 박육부재의 압궤특성에 관한 연구)

  • 김정호;임성훈;양인영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.1-14
    • /
    • 1997
  • In this paper, collapse test of thin-walled structural member widely used for automobiles is carried out under static compression load to observe the effects of cross- sectional shape and material on the energy absorbing capacity in the viewpoint of cras- hworthiness. Specimens tested consist of two sorts(Aluminium, CFRP) and configur- ations(Circular, Square) with variation in thickness. Also, comparisons of Al circular and square specimens are made to find the influence of difference in shape on the energy absorbing capability according as the thickness of specimen varies.

  • PDF

Analysis on the Crashworthiness of the Full Rake Korean Electric Multiple Unit Train (한국형 표준전동차 전체차량의 충돌안전도 해석 연구)

  • 구정서;김동성;조현직;권태수;최성규
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • In this paper, numerically evaluated is the crashworthiness of the new design of the standard Korea Electric Multiple Unit Train(K-EMU)[developed by the Korea Railway Research Institute]. The 4-car consist of K-EMU is analyzed under collision conditions such as normal coupling, heavy shunting, light collision and heavy collision to collide against another stationary one at 5 kph, 10 kph, 25 kph and 32 kph, respectively. Energy absorbing capacity of its draftgear commercially available in the market and to be equipped in K-EMU is evaluated under each collision condition. Analytical results show that draftgear only is not enough to provide necessary energy absorbing capacity. It is therefore concluded that additional energy absorbers like mechanical fuses should be adopted to improve the crashworthiness of K-EMU.

  • PDF

Evaluation of Absorbing Energy for the Rockfall Protection Fence Using High Carbon Steel Wire Rods (경강선 적용 낙석방지울타리의 흡수에너지 평가)

  • Lee, Yongjoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.49-60
    • /
    • 2009
  • In order to develop a new rockfall protection fence using high carbon steel wire rod (HSWR) material instead of the conventional wire rope material, the author has conducted the laboratory strength tests of both materials and their connections, and carried out evaluation of absorbing rockfall energy through the vertical field rockfall tests. The vertical filed rockfall tests showed that the new rockfall protection fence with 12 rows of the HSWR could absorb more rockfall energy than 50 kJ which stands for the typical design criteria. In addition, when the quantity of HSWR was increased up to the 16 rows, the capacity of absorbing energy was greatly improved. The new rockfall protection fence was successfully applied to the highway rock-cut slope. As a result of the filed application, its constructability was similar to the conventional fence, but its total image was improved as simple and clean. The total construction cost was saved up to 20% in comparison with the conventional one.

  • PDF

Estimation of Plastic Energy Dissipation Amount of Multi-bent Spatial structure by Equivalent Linear Analysis

  • Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.131-136
    • /
    • 2006
  • It is important to evaluate energy absorption capacity of frames required during a design earthquake. An inelastic computer analysis based on mathematical modelling of energy absorbing frames and elements makes it possible to evaluate required energy absorption capacity. But such an analysis sometimes consumes much computation time particularly in case of complicated structural system. This paper presents a proposal to predict energy absorption of multi-bent steel frames by simple equivalent linear method.

  • PDF

Experimental Investigation of the Sound Absorption Capability of Wood Pellets as an Eco-Friendly Material

  • JANG, Eun-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.126-133
    • /
    • 2022
  • In this study, I used wood pellets as an eco-friendly sound-absorbing material. The aim of the research was to analyze the effect of the filling height of wood pellets on sound absorption. This was done using two types of wood pellets of different lengths (A group: 1.5-3 cm, B group: less than 1.5 cm). With increasing filling height of the wood pellets, the optimum sound absorption shifted towards a lower frequency. The group B wood pellets had better sound absorption capacity than the group A ones. The optimum sound absorption coefficient of group A filled to a height of 7 cm was 0.722 at 864 Hz. On the other hand, that of group B filled to a height of 7 cm was 0.764 at 862 Hz, 5.82% higher than that of group A. While wood pellets are used as an eco-friendly fuel, the results of this study suggest the possibility of using wood pellets as an eco-friendly sound-absorbing material.

Energy Absorbing Control Characteristic of Al Thin-walled Tubes (AL 박육부재의 에너지 흡수 제어특성)

  • Yang, Yong-Jun;Yang, In-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • The structural members must be designed to control characteristics of energy absorption for protecting passengers in a car accident. Study on collapse characteristics of structural member is currently conducted in parallel with other studies on effective energy absorption capacity of structural members with diverse cross-sectional shapes and various materials. This study concerns the crashworthiness of the widely used vehicle structural members, square thin-walled tubes, which are excellent in the point of the energy absorption capacity. The absorbed energy, mean collapse load and deformation mode were analyzed for side member which absorbs most of the collision energy. To predict and control the energy absorption, controller is designed in consideration of its influence on height, thickness and width ration in this study. The absorbed energy and mean collapse load of square tubes were increased by $15{\sim}20%$ in using the controller, and energy absorbing capability of the specimen was slightly changed by change of the high controller's height.

Characteristics and Energy Absorbing Capacity for Rockfall Protection Fence from In-Situ Rockfall Tests (현장 낙석실험을 통한 낙석방지울타리의 특성 및 성능 평가)

  • 구호본;박혁진;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.111-121
    • /
    • 2001
  • Rockfall protection fences are used for diminishing rockfall damage in roads side slopes. In order to install the fences in effective way, the conditions of rock slopes and total predicted impact energy of fa11ing rock should be considered. However, the fences have been constructed without any consideration for lithology, height and slope angle of rock slope in Korea. In addition, the information about the performance of the protection fences, which should be evaluated by in-situ test or laboratory test in order to check out the practical use in the field, is not available. Therefore, in design manual for the rockfall protection fence, the specific details for the installation of this type of fence are not provided yet. The full sized rockfall in situ test was carried out for the calculation of falling energy of rock and the evaluation of the maximum energy absorbing capacity of fence. For this test, the rock slopes whose heights are about 20 m and dip angle of 65 degree, have been chosen. This is because those geometries are mean height and slope angle of most road cut slopes along Korean national highway. Based on the preliminary simulation procedure, four different sizes of concrete ball (0.7, 1.3, 2.3 and 4.3 ton) were prepared and flour different types of protection fence were constructed. The results of this test provide information about the maximum energy absorbing capacity of the fence, kinetic energy of rockfall and restitution coefficient, and these results can be utilized in the establishment of rockfall fence design and construction manual.

  • PDF