• Title/Summary/Keyword: Absorbed dosimetry

Search Result 138, Processing Time 0.024 seconds

Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment (PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가)

  • Cho, Yong-In;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.237-244
    • /
    • 2015
  • Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose reduction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose distribution was different due to characteristics of dosimetry device. However, spatial dose rate was exponentially reduced according to distance with increasing lead content.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

Beta Dosimetry in Intraperitoneal Administration of 166Ho-chitosan Complex (166Ho-chitosan 복합체의 복강 내 투여를 위한 베타선 흡수선량 평가)

  • Kim, Eun-Hee;Lim, Sang-Moo;Park, Kyung-Bae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.99-108
    • /
    • 1998
  • Intraperitoneal administration of radioisotopes is suggested to treat the metastatic ovarian cancer in the peritoneal cavity. Administering beta-emitting radioisotopes into the peritoneal cavity allows the maximum energy delivery to the cancerous cells of the peritoneal wall surface while sparing the normal cells located in deep site of the peritoneal wall. In this study, dose estimates of the peritoneal wall are provided to be used for prescribing the amount of $^{166}Ho$-chitosan complex administered. The $^{166}Ho$-chitosan complex diffused in the peritoneal fluid may attach to the peritoneal wall surface. The attachment fraction of $^{166}Ho$-chitosan complex to the peritoneal wall surface is obtained by simulating the ascites with Fischer rats. Both volume source in the peritoneal fluid and the surface source over the peritoneal wall surface are counted for the contribution to the peritoneal wall dose. The Monte Carlo code EGS4 is used to simulate the energy transfer of the beta particles emitted from $^{166}Ho$. A plane geometrical model of semi-infinite volume describes the peritoneal cavity and the peritoneal wall. A semi-infinite plane of $10{\mu}m$ in thickness at every 1 mm of depth in the peritoneal wall is taken as the target in dose estimation. Greater than 98 percents of attachment fraction has been observed from the experiments with Fischer rats. Given $1.3{\mu}Ci/cm^2$ and $2.4{\mu}Ci/ml$ of uniform activity density, absorbed dose is 123 Gy, 8.59 Gy, 3.00 Gy, 1.03 Gy, and .327 Gy at 0 mm, 1 mm, 2 mm, 3 mm, and 4 mm in depth to the peritoneal wall, respectively.

  • PDF

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors

  • Kwon, Seog-Guen;Kim, Kyung-Eung;Ha, Chung-Woo;Moon, Philip S.;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.171-179
    • /
    • 1980
  • This paper presentss flux-to-dose conversion factors for neutrons and gamma-rays based on the concept of the maximum absorbed dose. Neutron flux-to-does-rate conversion factors for energies from 2.5$\times$10$^{-8}$ to 20 MeV are presented while the conversion factors for gamma-rays are given in the energy range of 0.01 to 15MeV. Flux-to-does-rate conversion factors, which were calculated under the assumption that the radiation energy distribution has nonlinearity in phantom, are different from those values obtained by monoenergetic radiation. Especially, these values obtained here were determined for the cross section libray such as DLC-23, DLC-27, and DLC-31. The flux-to-dose-rate conversion factors obtained in this work are in a good agreement with the values presented by American National Standard Institute (ANSI) N666. These results are used to calculate the dose rate distribution of neutron and gamma-ray in any radiation fields, and will be useful for the radiation shielding analysis, radiation protection and radiation dosimetry concerned with problems of continuous energy distribution.

  • PDF

KFDA TLD Dose Quality Audit and Measurement Uncertainty (식품의약품안전청의 치료방사선 선량보증과 측정불확도)

  • Jeong, Hee-Kyo;Lee, Hyun-Ku;Kim, Gwe-Ya;Yang, Hyun-Kyu;Lim, Chun-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.153-156
    • /
    • 2004
  • Korea Food and Drug Administration(KFDA) has peformed the calibration of therapy level dosimeters for Co-60 radiation since 1979. The reference standard ionization chamber has been calibrated at BIPM in France. The uncertainty on the KFDA calibration coefficients is 0.9 %(k=2) for air kerma and absorbed dose to water. Since 1999 a national quality audit program for ensuring dosimetry accuracy in Korea radiotherapy centers has been performed by the KFDA. The uncertainty associated with the determination of the absorbed dose to water from the TLD readings for high energy x-ray is 1.6 %(k=1). The correction factors for energy, non-linearity dose response, and TLD holder are used in the dose determination. Agreement between the user stated dose and KFDA measured dose within ${\pm}$ 5 % is considered acceptable. KFDA TLD postal dose quality audit program was peformed for 71 beam qualities of 53 domestic radiotherapy centers in 2003. The results for quality assurance showed that 63 out of 71 beam qualifies (89 %) satisfied the acceptance limit. The second audit was carried out for the centers outside the limit and ail of them have been corrected.

  • PDF

Variation of Dose due to the Wound Electrode of Ionization Chamber (굴곡이 있는 전리함 집전극에 기인한 선량 변화)

  • Lee, Byung-Koo;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.203-209
    • /
    • 2008
  • Nowadays the risk of radiation is getting more serious, so we must know the exact dose that was irradiated, Because very high radiation dose is used in radiation therapy field. We used the ionization chamber which measure the radiation dose in this study. We tried to know the incorrect result from the distortion of geometric structure of ionization chamber and we studied how to find the distortion of geometric structure of ionization chamber. We used a radio fluoroscopy to find the wound degree of electrode of ionization chamber and a reconstructed 3D CT image to analyze the wound degree of electrode quantitatively. we measured degree of distortion by comparing with absorbed dose of normal electrode and wound electrode. The comparative result is not absolute dosimetry at specific point but relative dosimetry between thats. We measured 4 MV, 10MV photon with same absorbed dose and dose rate. The degree of distortion of wound electrode was totally $5.5{\sim}7.2%$, and there was no difference between two energies. The variation induced from radiation dose to be irradiated and dose rate, and the degree of distortion from wound direction also was almost similar value. We could find that the geometric structure of ionization chamber that can influence a basic measurement of radiation dose can be changed by old usage and inattention of management in this study, especially winding of electrode can be happened, in radiation therapy field, It is very important to keep precise radiation dose quantitatively.

Cytokinesis-blocked micronuclei in the human peripheral lymphocytes following low dose γ-rays irradiation (저선량의 감마선 피폭된 사람 말초 임파구의 미소핵을 이용한 방사선 생물학적 피폭선량 측정법 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.99-104
    • /
    • 2001
  • To determine if micronucleus (MN) assay could be used to predict the absorbed dose of victims after accidental radiation exposure, we carried out to assess the absorbed dose depending on the numerical changes of MN in human peripheral blood lymphocytes after $^{60}Co\;{\gamma}-rays$ exposure in the range of 0.25 to 1 Gy, respectively. The MNs were observed at very low doses, and the numerical changes according to doses. Satisfactory dose-effect calibration curve is observed after low dose irradiation of human lymphocytes in vitro. When plotting on a linear scale against radiation dose, the line of best fit was $Y=(0.02{\pm}0.0009)+(0.033{\pm}0.010)D+(0.012{\pm}0.012)D^2$. The dose-response curve for MN induction immediately after irradiation was linear-quadratic and has a significant relationship between the frequencies of MN and dose. These data show a trend towards increase of the numbers of MN with increasing dose. The number of MN in lymphocytes that were observed in the control group is $0.1610{\pm}0.0093/cell$. Accordingly, MN assay in human peripheral lymphocytes could be a useful in viva model for studying radio-protective drug sensitivity or screening test, microdosimertic indicator and radiation-induced target organ injury. Since MN assay is simple, rapid and reproducible, it will also be a biodosimetric indicator for individual dose assessment after accidental exposure.

  • PDF

Absorbed Dose Determination for a Biological Sample Irradiated by Gamma Rays from a Cs-137 Source (Cs-137 감마선에 대한 생물학 연구용 시료의 흡수선량 결정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jeung-Kee;Yang, Kwang-Mo;Ju, Min-Su;Kim, Min-Young;Lee, Chang-Yeol;Kim, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.124-130
    • /
    • 2011
  • In this study the dosimetric evaluation for a biological sample irradiated by gamma rays from Cs-137 irradiator (Gamma Irradiator, Chiyoda Technol Co., Japan) was performed for radiobiological experiment. A spherical water with a diameter of 3 cm was assumed as a biological sample. The absorbed dose were determined by the air kerma based dosimetric calculation system. The theoretical and Monte Carlo calculations (MCNPX) were performed and compared to evaluate measured air kerma and determined absorbed dose respectively. As a result of comparison with theoretical calculation, the measured air kerma was in good agreement within 3.1% at the distance of 100 and 200 cm from the source. In comparison with Monte Carlo results the determined absorbed dose along the central axis was in good agreement within 1.9% and 3.7% at 100 cm and 200 cm respectively. Although the preliminary results were obtained in this study these results were used as a basis of dosimetric evaluation for radiobiological experiment. Extended study will be performed to evaluate the dose in various conditions of biological samples.