6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Comparison of Air Kerma and Absorbed Dose to Water Based Protocols for High Energy Photon Beams: Theoretical and Experimental Study

  • Shin, Dong-Oh;Kim, Seong-Hoon;Seo, Won-Seop;Park, Sung-Yong;Park, Jin-Ho;Kang, Jin-Oh;Hong, Seong-Eon;Ahn, Hee-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.241-243
    • /
    • 2002
  • New types of protocols have been recently in development, all based on an absorbed dose-to-water with the aim of improving the accuracy of measurements of absorbed dose to water. IAEA TRS-277, the air-kerma standard-based present protocol, and IAEA TRS-398 and AAPM TG-51, the absorbed dose-to-water standard-based new one, were studied and compared theoretically and experimentally for photon beams of 6, 10, and 15 MV. NE 2571 and 3 Farmer types of ionization chambers in widely commercial use were used to determine an absorbed dose to water at the reference depth in water. Two different kinds of calibration factors were given respectively for every chamber calibrated in $\^$60/CO gamma ray beams from a Korean Secondary Standard Dosimetry Laboratory (KFDA). This work shows that there is around 1 % of difference of absorbed doses measured between two different types of calibration systems owing to different physical parameters and reference conditions used. We hope this work to help form the basis on development of new type of protocol in Korea.

  • PDF

물 흡수선량 표준에 기반한 선량교정 프로그램 개발 (Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.175-183
    • /
    • 2003
  • 최근 선량측정의 정확성을 향상시키기 위하여 기존의 공기커마 교정인수에 기반한 표준측정법에서 물 흡수선량 교정인수에 기반한 표준측정법으로 변환하고 있는 추세이다. 본 연구에서는 미국의학물리학회의 AAPM TG-51과 국제원자력기구의 IAEA TRS-398 표준측정법에 대한 선량교정 프로그램을 개발하였다. 이 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 C++언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스화함으로써 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화 (Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards)

  • 김성훈;허현도;최상현;김찬형;민철희;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2009
  • 본 논문은 물 흡수선량 표준에 기반하여 근접치료 선원인 $^{192}Ir$을 교정하는 것에 대한 예비적 연구를 위한 것이다. 이온함을 사용하여 물흡수선량 표준에 기반하여 근접치료 선원을 교정하기 위해선, 빔 선질 교정인자인 $k_{Q,Q_0}$가 필요하다. 본 연구에선 일차 표준을 사용하여 지정된 거리에서의 흡수선량를 측정하는 데 있어서의 현실적인 어려움 때문에 몬테칼로 전산모사와 반실험적인 방법을 통하여 $k_{Q,Q_0}$를 결정하였다. 본 연구를 위해 PTW30013 이온함 5개를 선택하였다. 포괄적 $k^{gen}_{Q,Q_0}$ 값의 경우엔 이온함간 변화가 최대 4.0%에 이른 반면, 개별적 $k^{ind}_{Q,Q_0}$ 경우엔 이온함간 변화가 최대 0.5% 이내였다. 이 결과는 물 흡수선량에 기반하여 근접치료 선원인 $^{192}Ir$을 교정시에 이온함을 왜 개별적으로 교정해야 하는지, 개별적인 교정이 얼마나 중요한 지를 보여 준다. 가까운 장래에 공기커마 세기 대신에 사용자가 근접치료 선원을 고에너지 광자빔과 전자빔의 교정에서처럼 치료에서 관심있는 물리량인 물흡수선량의 관점에서 교정할 수 있기를 희망한다.

  • PDF

Bilateral comparison of the absorbed dose to water in high energy X-ray beams between the KRISS and the NMIJ

  • Kim, In Jung;Kim, Byoung Chul;Yi, Chul-Young;Shimizu, Morihito;Morishita, Yuichiro;Saito, Norio
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1511-1516
    • /
    • 2020
  • The Korea Research Institute of Standards and Science (KRISS) established a new standard of the absorbed dose to water in LINAC X-ray beams. To confirm the equivalence of the new standard with other national metrology institutes (NMIs), a bilateral comparison study of the absorbed dose to water in high energy X-ray beams was performed between the KRISS and the National Metrology Institute of Japan (NMIJ). The comparison was made in-directly. Three transfer chambers were calibrated in the high energy X-ray beams by both laboratories and the calibration coefficients were compared. The average ratios of the calibration coefficients of the three transfer chambers obtained by the KRISS to those obtained by the NMIJ were 1.004, 1.006, 1.006, 1.007 for 6, 10, 15 and 18 MV X-ray beams, respectively. The calibration coefficients obtained at the KRISS were higher than those at the NMIJ but they were in good agreement within the expanded uncertainty of 1.0% (k = 2). The results of this study will be used as the evidence for the KRISS standard being comparable with those of other NMIs, temporarily, in the interim period up to finalizing a key comparison study, BIPM.RI(I)-K6 managed by the Consultative Committee for Ionizing Radiation.

6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남;박성용;서태석;권수일;윤세철
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.87-102
    • /
    • 1997
  • 목적 : 방사선량 측정시 에너지, 매질, 측정기 등의 측정 조건과 측정 프로토콜에 따라 절대 흡수선량값이 결정된다. 본 연구에서는 이러한 측정 조건의 변화와 측정 프로토콜의 차이에 따른 절대 선량 값을 구하여 비교 분석 하고자 한다. 방법 : 시멘스 선형가속기에서 발생하는 6MV 광자선을 이용하여 3개의 다른 매질(물, 고체 물팬텀, 폴리스틸렌팬텀)내에서 2개의 전리함 (PTW ion chamber, NEL ion chamber)과 2개의 전기계(Victoreen electrometer, Keithley electrometer)를 사용하여 흡수선량을 측정하였다. 매질, 전리함, 전기계등의 측정 조건을 달리하여 서로 다른 조합에 대한 측정값을 TG21, IAEA 프로토콜에 의해 각각 분석하였다. 결과 및 결론 : 2개의 전기계와 2개의 전리함 조합에 따른 TG2l 및 IAEA 의 Ngas,, ND값의 비는 평균적으로 1% 이내에서 일치하였다. 3개의 서로 다른 매질, 4개의 서로 다른 전리함 및 전기계 조합에 따른 12 가지 측정조건에 대한 흡수선량의 변화는 평균 0.6%의 차이를 보여 주였으며 임의의 전리함 및 전기계 조합에 대하여 물팬텀 및 고체물팬텀에 대한 TG21, MEA 측정법에 의한 흡수선량비의 변화 양상이 같은 양상을 보여주고 있으나 그 차이가 평균 1.96%를 보임으로서 고체물팬텀이 절대 흡수선량 측정에는 적절치 않은 것으로 사료된다. TG21 측정법에 따른 물팬텀과 폴리스틸렌팬텀을 이용한 절대 흡수선량값이 1.54%의 차이를 보임으로서 팬텀 매질에 대한 비교 factor가 필요할 것으로 사료된다. 측정매질, 전리함, 전기계 등의 여러 조건에 대한 흡수선량값의 차이가 TG21, IAEA 프로토콜에서 1% 이내의 차이를 보여 주고 있으며 상대적인 변화 양상이 측정법에 상관없이 같은 경향으로 변함으로서 측정조건이 측정법에 영향을 주지 않았음을 알 수 있다. 다만 표준 측정법을 사용할 때 팬텀에 의한 차이는 많이 날 수 있으므로 측정법에서 사용하는 표준 팬텀을 사용 할 것을 권장하며 이것이 어려운 경우는 병원에서 사용하는 팬텀에 대한 보정값을 자체적으로 구하여 사용하는 것이 오차를 줄일 수 있을 것으로 사료된다.

  • PDF

고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발 (Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams)

  • 신동오;박성용;지영훈;이창건;서태석;권수일;안희경;강진오;홍성언
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.381-390
    • /
    • 2002
  • 목적 : 고 에너지 광자선에 대한 기준점에서의 물 흡수선량 계산을 절차상 또는 계산상의 오류를 피하기 위해 공기커마(혹은 조사선량) 교정정수에 토대를 두고 있는 IAEA TRS-277과 AAPM TG-21 및 최근 발표된 새로운 개념의 물 흡수선량 교정정수에 토대를 두고 있는 IAEA TRS-398과 AAPM TG-51 표준측정법에 기초한 고 에너지 광자선의 선량 교정 프로그램을 개발하고자 한다. 대상 및 방법 : 현재 국내외에서 널리 사용되고 있는 고 에너지 광자선에 대한 흡수선량 표준측정법은 IAEA TRS-277과 AAPM TG-21로서 공기커마(혹은 조사선량) 교정정수에 토대를 두고 있어 수식 체계가 복잡하고, 사용된 물리량에 대한 불확정도가 커서 선량측정의 정확성을 향상시키는데 한계가 있다. 최근 국제원자력기구와 미국의학물리학회에서는 새로운 개념의 물 흡수선량 교정정수에 토대를 두고 있는 IAEA TRS-398과 AAPM TG-51을 발표하였다. 개발된 네 종류의 선량 교정 프로그램은 이들 표준측정법에서 사용되고 있는 수식체계와 물리적인 매개변수를 엄격하게 적용하였고, 선량계에 대한 정보 및 물리적인 값에 대한 표와 그래프 값은 수치화하여 데이터베이스화하였다. 이들 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 $C^{++}$ 언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 결과 : 네 종류의 표준측정법에 대하여 개발된 고 에너지 광자선에 대한 선량 교정 프로그램은 사용자가 병원에서 사용하고 있는 표준측정법을 선택하여 선량측정 절차에 따라 선량계, 선질 특성 및 측정 조건에 관한 정보와 측정 결과를 입력하고, 순차적으로 수행하도록 되어 있어 절차상 혹은 선량 계산에 있어서 사용자간의 오차 및 실수를 최소화할 수 있었다 또한 서로 다른 개념의 네 종류의 표준측정법에 대한 기준점에서의 선량값을 상호 비교할 수 있었다. 결론 : 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스함으로써 수작업으로 각 프로토콜의 수행 절차상 혹은 사용자간의 발생할 수 있는 개인적인 실수 및 오차를 줄일 수 있었다. 또한 이 프로그램은 사용자 편의성을 고려하였고, 모든 보정계수와 물흡수선량을 정확하게 계산할 수 있기 때문에 각 표준측정법에 대한 주요한 차이점을 비교 분석할 수 있어 사용자가 적당한 표준측정법을 선택하여 수행하므로써 고 에너지 광자선 선량 교정에 이용시 매우 유익할 것으로 사료된다.

연구용 세슘-137 조사기에 대한 흡수선량 측정과 유리선량계 교정에 관한 연구 (Reference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays)

  • 문영민;이동주;김정기;강영록;이만우;임희진;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.140-144
    • /
    • 2013
  • 본 연구에서는 방사선생물 분야에서는 사용하는 세슘-137 조사기에 대한 기준 흡수선량을 측정하고 시료의 방사선량 평가에 활용하기 위하여 유리선량계를 교정하였다. 세슘-137 감마선에 대하여 IAEA TRS-277 프로토콜을 적용하여 정밀하게 물흡수선량을 결정하였다. 기준 흡수선량 측정에는 PTW-TM300013 전리함과 PTW-TM41023 물팬텀을 사용하였으며, 유리선량계는 DoseAce사의 GD-302M 모델을 사용하였다. 교정된 유리선량계의 불확도(1 SD)는 약 2.7%로 평가되며, 본 결과는 연구용 시료의 방사선량 측정에 이용될 예정이다.

웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발 (Development of Web-based Dosimetry Calibration Program for High Energy Radiation)

  • 신동오;신동호;김성훈;박성용;서원섭;안희경;강진오;홍성언
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.116-124
    • /
    • 2005
  • 고 에너지 광자선과 전자선의 흡수선량 결정에 대한 표준측정법은 공기커마 교정인수를 바탕으로 한 방법이 널리 사용되고 있으나 복잡한 수식과 물리적인자의 불확실성 등으로 정확도 향상에 한계가 있다. 따라서 최근 국제원자력기구와 미국의학물리학회에서 물 흡수선량을 기반으로 표준측정법을 개발하였다. 본 연구는 국제원자력기구의 IAEA TRS-398 과 미국의학물리학회의 AAPM 7e-51 물 흡수선량 표준측정법에 대한 인터넷을 기반으로 하는 선량교정 프로그램을 개발하였다. 이 프로그램은 인터넷 온라인상에서 사용할 수 있도록 C$\#$ 언어를 사용하여 각각의 표준측정법의 절차에 따라 사용자의 편의를 고려하여 개발하였다. 사용자는 인터넷을 통해 기준점에서의 두 가지 절차서에 따른 물 흡수선량을 비교할 수 있으며, 국내 각 기관에서 수행된 선량교정의 추세를 이해하고 보다 쉽게 관리할 수 있게 하였다. 웹 기반 데이터베이스를 이용하여 차후 국내 실정에 적합한 물 흡수선량 표준에 기반을 둔 표준측정법을 개발하는데 기여할 것으로 기대된다

  • PDF

기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발 (The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source)

  • 허현도;김우철;노준규;이석;이상훈;조삼주;신동오;최진호;권수일;김성훈
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.232-237
    • /
    • 2006
  • 본 연구의 목적은 Ir-192 선원의 검교정을 겉보기 방사능(apparent activity)을 이용하지 않고 물속 기준점에서 흡수선량을 측정함으로써 공기커마 세기(air-kerma strength, Sk)를 계산하고자 알고리즘을 개발하였다. 연구를 위하여 근접치료용 다목적 팬톰(multi purpose brachytherapy Phantom, MPBP)을 제작하였다. 물 흡수선량 측정은 고선량률 근접치료기(micro-Selectron, Nucletron, Netherlands)에 장착된 Ir-192 선원(Mallinckrodt Medical B.V., Netherlands)을 대상으로 측정하였다. 물 흡수선량은 몬테칼로 계산방법으로 계산된 이온전리함(TM30013, PTW, Germany)의 물 흡수선량 교정인자($N_{D.W.Q}$)를 이용하여 결정하였다. 물 흡수선량은 한 개의 선원에 대하여 4 cm에서 7 cm까지 측정하였다. 측정된 값은 전산화 치료계획 장치에서(plato BPS, ver 13.2, Nucletron, Netherlands) 계산된 값과 비교하였다. 공기커마 세기(Sk)는 기준점 5 cm되는 곳에서 3개의 Ir 선원에 대하여 구하였다. 계산된 공기커마 세기는 선원제조사에서 제공된 값과 비교하였다. 몬테칼로 계산방법으로 계산된 이온전리함의 물 흡수선량 교정인자는 5.28 cGy/nC이었다. 한 개 선원에서 측정한 물 흡수선량 값은 -2.16%에서 -0.84%까지 상대오차를 나타내었다. 공기커마 세기는 제조사에서 제공된 값과 비교하여 -0.6%에서 +1.8% 제조사 권고치 ${\pm}5%$ 이내로 잘 일치하였다. 본 연구에서 개발한 알고리즘은 기준점에서의 물 흡수선량을 정확히 결정함으로써 선원의 공기커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다.

  • PDF