• Title/Summary/Keyword: Absorbed Spectrum

Search Result 64, Processing Time 0.026 seconds

Analysis of the Spectrum Characteristics of Etched Glass Surface by Incident Angle (입사각에 따른 에칭 기판의 분광특성분석)

  • Kim, Haemaro;Lee, Don-Kyu
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1077-1081
    • /
    • 2019
  • Lights that enter the surface of a solar cell cannot be absorbed inside all of the solar cells, and some of it is reflected off the surface of the substrate, resulting in loss. Because of this, many studies are underway to reduce reflective losses on the surface of substrates or to steam the generated charge inside the solar cell. In this paper, surface treatment for forming a rough surface by wet etching the surface of a glass substrate is advanced, and structural characteristics of the rough surface are analyzed. Then, spectral characteristics by changing the angle of the glass substrate to which light enters the company are analyzed. When the light entering the company is investigated on a etched surface, it is confirmed that the probability of re-absorbing the light inside the glass substrate by multiple reflection is increased. When entering the light while changing the angle of the glass substrate, the transmission and reflection performance of the light are not changed.

Photo-Transistors Based on Bulk-Heterojunction Organic Semiconductors for Underwater Visible-Light Communications (가시광 수중 무선통신을 위한 이종접합 유기물 반도체 기반 고감도 포토트랜지스터 연구)

  • Jeong-Min Lee;Sung Yong Seo;Young Soo Lim;Kang-Jun Baeg
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.143-150
    • /
    • 2023
  • Underwater wireless communication is a challenging issue for realizing the smart aqua-farm and various marine activities for exploring the ocean and environmental monitoring. In comparison to acoustic and radio frequency technologies, the visible light communication is the most promising method to transmit data with a higher speed in complex underwater environments. To send data at a speedier rate, high-performance photodetectors are essentially required to receive blue and/or cyan-blue light that are transmitted from the light sources in a light-fidelity (Li-Fi) system. Here, we fabricated high-performance organic phototransistors (OPTs) based on P-type donor polymer (PTO2) and N-type acceptor small molecule (IT-4F) blend semiconductors. Bulk-heterojunction (BHJ) PTO2:IT-4F photo-active layer has a broad absorption spectrum in the range of 450~550 nm wavelength. Solution-processed OPTs showed a high photo-responsivity >1,000 mA/W, a large photo-sensitivity >103, a fast response time, and reproducible light-On/Off switching characteristics even under a weak incident light. BHJ organic semiconductors absorbed photons and generated excitons, and efficiently dissociated to electron and hole carriers at the donor-acceptor interface. Printed and flexible OPTs can be widely used as Li-Fi receivers and image sensors for underwater communication and underwater internet of things (UIoTs).

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Acute pyelonephritis and myositis after carboxytherapy : A case report (카르복시테라피 후 발생한 급성 신우신염 및 근육염 : 증례 보고)

  • Sun, KyungHoon;Heo, JunHo;Hwang, Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.417-421
    • /
    • 2018
  • Carboxytherapy is very similar to mesotherapy in terms of methods, conditions it treats, and outcomes. An important difference consider, however, is that carboxytherapy administers carbon dioxide gas into the subcutaneous layer, just underneath the skin, whereas mesotherapy administers a cocktail of vitamins, minerals, and drugs and into the mesoderm of the skin. There have been many previous case reports of complications of mesotherapy such as hematoma, granulomatous panniculitis, cellulitis, and abscesses. However, complications of carboxytherapy have rarely been reported because the carbon dioxide gas is absorbed within a week and is infused into the subcutaneous and superficial layers. A 27-year-old woman who had twice undergone carboxytherapy to reduce abdominal fat (3 days and 2 weeks ago) at an oriental medical clinic visited the emergency department due to high fever, myalgia, severe back pain, and subcutaneous emphysema from the buttocks to the lower chest wall area. A computed tomography (CT) scan was performed for diagnosis and treatment. We immediately started broad spectrum antibiotics and consulted with the department of radiology, which could not rule out acute peritonitis due to needle injury. A radiologist confirmed abdominal myositis and needle puncture induced acute pyelonephritis. Pyelonephritis can even lead to septicemia, which can have fatal consequences. Therefore, if the patient has costovertebral or back pain after undergoing needle puncture or acupuncture therapy, the emergency physcians need careful initial evaluation for diagnosis and treatment.

Fabrication of a Schottky Type Ultraviolet Photodetector Using GaN Layer (GaN를 이용한 Schottky diode형 자외선 수광소자의 제작)

  • Seong, Ik-Joong;Lee, Suk-Hun;Lee, Chae-Hyang;Lee, Yong-Hyun;Lee, Jung-Hee;Hahm, Sung-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.28-34
    • /
    • 1999
  • We fabricated a planar ultra-violet photodetector whose ohmic and schottky contacts were respectively formed with evaporated Al and Pt on the GaN layer. To examine the applicability of the device to the UV sensor, we investigated its electrical and optical characteristics. The GaN layer on the sapphire waver had $7.8{\times}10^{16}cm^{-3}$ of doping concentnation and the $138 cm^2/V{\cdot}s$ of electron mobility and it absorbed the spectrum of the light below 325 nm wavelength. It had the responsivity of 2.8 A/W of at 325 nm, and the signal to noise ratio(SNR) of $4{\times}10^4$, and the noise equivalent power(NEP) of $3.5{\times}10^9$W under 5 V reverse bias. These results confirmed that the GaN schottky diode had a solar blind properly when it was applied to the UV photodetector.

  • PDF

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Synthesis of Aminated Poly(ether sulfone) as Anion Exchanger and its NO Gas Adsorption (Aminated Poly(ether sulfone)의 합성과 NO 가스의 흡착특성)

  • Son, W.K.;Park, S.G.
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.857-862
    • /
    • 1999
  • Aminated poly(ether sulfone)(APES) was prepared by amination of nitrated poly(ether sulfone)(NPES) after poly(ether sulfone)(PES) was nitrated with mixed acid of nitric acid and sulfuric acid(sulfuric acid is a catalyst). As a results of the FT-IR spectrum analysis, the nitration of PES was confirmed by the bands of asymmetric stretching and symmetric stretching of $NO_2$ group at 1537 and $1351cm^{-1}$, respectively. Also when the NPES was aminated, it was disappeared to absorbance peaks of $NO_2$ group. And It was confirmed by the bands of asymmetric stretching and symmetric stretching of $NH_2$ group at 3470 and $3374cm^{-1}$, respectively. The optimum condition of the nitration on PES(5 g; 21.55 mmol.) was 12 hr of reaction time, $120^{\circ}C$ of reaction temperature, nitric acid of 28.00 mmol. and sulfuric acid of 52.00 mmol. As a result of the elemental analysis of APES, reapeating unit per amine groups were induced to 0.89. The adsorption rate of NO gas was lower than that of silica gel and active carbon. But the adsorption capacity of NO gas was higher than that of these. When the APES was absorbed to NO gas, the chemical adsorption rate was lower than the physical adsorption rate. But the chemical adsorption capacity of it was higher than physical adsorption capacity.

  • PDF

Photodecomposition of Concentrated Ammonia over Nanometer-sized TiO2, V-TiO2, and Pt/V-TiO2 Photocatalysts

  • Choi, Hyung-Joo;Kim, Jun-Sik;Kang, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.581-588
    • /
    • 2007
  • To enhance the photodecomposition of concentrated ammonia into N2, Pt/V-TiO2 photocatalysts were prepared using solvothermal and impregnation methods. Nanometer-sized particles of 0.1, 0.5 and 1.0 mol% V-TiO2 were prepared solvothermally, and then impregnated with 1.0 wt% Pt. The X-ray diffraction (XRD) peaks assigned to V2O5 at 30.20 (010) and Pt metal at 39.80 (111) and 46.20 (200) were seen in the 1.0 wt% Pt/ 10.0 mol% V-TiO2. The particle size increased in the order: pure TiO2, V-TiO2 and Pt/V-TiO2 after thermal treatment at 500 °C, while their surface areas were in the reverse order. On X-ray photoelectron spectroscopy (XPS), the bands assigned to the Ti2p3/2 and Ti2p1/2 of Ti4+-O were seen in all the photocatalysts, and the binding energies increased in the order: TiO2 < Pt/V-TiO2 < V-TiO2. The XPS bands assigned to the V2p3/2 (517.85, 519.35, and 520.55 eV) and V2p1/2 (524.90 eV) in the V3+, V4+ and V5+ oxides appeared over V-TiO2, respectively, while the band shifted to a lower binding energy with Pt impregnation. The Pt components of Pt/ V-TiO2 were identified at 71.60, 73.80, 75.00 and 76.90 eV, which were assigned to metallic Pt 4f7/2, PtO 4f7/2, PtO2 4f7/2, and PtO 4f5/2, respectively. The UV-visible absorption band shifted closer towards the visible region of the spectrum in V-TiO2 than in pure TiO2 and; surprisingly, the Pt/V-TiO2 absorbed at all wavelengths from 200 to 800 nm. The addition of vanadium generated a new acid site in the framework of TiO2, and the medium acidic site increased with Pt impregnation. The NH3 decomposition increased with the amount of vanadium compared to pure TiO2, and was enhanced with Pt impregnation. NH3 decomposition of 100% was attained over 1.0 wt% Pt/1.0 mol% V-TiO2 after 80 min under illumination with 365 nm light, although about 10% of the ammonia was converted into undesirable NO2 and NO. Various intermediates, such as NO2, -NH2, -NH and NO, were also identified in the Fourier transform infrared (FT-IR) spectra. From the gas chromatography (GC), FT-IR and GC/mass spectroscopy (GC/MS) analyses, partially oxidized NO and NO2 were found to predominate over V-TiO2 and pure TiO2, respectively, while both molecules were reduced over Pt/V-TiO2.