노말프로판올과 아세틱에씨드 계의 최소자연발화온도(AIT) 측정 및 예측 (Measurement and Prediction of Autoignition Temperature(AIT) of n-Propanol and Acetic acid System)

  • 하동명
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.66-71
    • /
    • 2017
  • The autoignition temperature (AIT) is crucial combustible characteristics which need attention in chemical process that handle hazardous materials. The AIT, also to as minimum spontaneous ignition temperature(MSIT), is the lowest temperature of a hot surface at which the substance will spontaneously ignite without any obvious sources of ignition such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for process safety. This study measured the AITs of n-propanol+acetic acid system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-propanol and acetic acid which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-propanol+acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). In the case of n-propanol and acetic acid system, the minimum autoignition temperature behavior (MAITB), which is lower than the lower AIT, is shown among the two pure substances constituting the mixture.

Temperature distribution prediction in longitudinal ballastless slab track with various neural network methods

  • Hanlin Liu;Wenhao Yuan;Rui Zhou;Yanliang Du;Jingmang Xu;Rong Chen
    • Smart Structures and Systems
    • /
    • 제32권2호
    • /
    • pp.83-99
    • /
    • 2023
  • The temperature prediction approaches of three important locations in an operational longitudinal slab track-bridge structure by using three typical neural network methods based on the field measuring platform of four meteorological factors and internal temperature. The measurement experiment of four meteorological factors (e.g., ambient temperature, solar radiation, wind speed, and humidity) temperature in the three locations of the longitudinal slab and base plate of three important locations (e.g., mid-span, beam end, and Wide-Narrow Joint) were conducted, and then their characteristics were analyzed, respectively. Furthermore, temperature prediction effects of three locations under five various meteorological conditions are tested by using three neural network methods, respectively, including the Artificial Neural Network (ANN), the Long Short-Term Memory (LSTM), and the Convolutional Neural Network (CNN). More importantly, the predicted effects of solar radiation in four meteorological factors could be identified with three indicators (e.g., Root Means Square Error, Mean Absolute Error, Correlation Coefficient of R2). In addition, the LSTM method shows the best performance, while the CNN method has the best prediction effect by only considering a single meteorological factor.

하절기 콘크리트의 품질특성 변화에 관한 연구 (A Study on the Quality Fluctuation of Hot Weather Concrete)

  • 김동석;정연식;유재상;김창범;이종열;김영준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.665-668
    • /
    • 2001
  • Generally, according to rising of atmospheric temperature, a consistency of concrete decreases, and a slump property of concrete is changed to be large. Also, in the strength development of concrete, the strength development rate of long-term age(28day) in comparison to strength of early age(7day) and the absolute compressive strength decreases. Accordingly, in this study, experiments about quality evaluation of concrete utilizing Ordinary Portland Cement is carried out. As a result of experiments, there were a conspicuous change in slump of concrete due to temperature increase. In conclusion, the rising of atmospheric temperature was very important factor in affecting the quality fluctuation of hot weather concrete.

  • PDF

The Determination of Stress Distribution in WC-Ni Cemented Carbide Composites by Neutron Diffraction

  • Seol, Kyeongwon
    • 한국재료학회지
    • /
    • 제5권2호
    • /
    • pp.232-238
    • /
    • 1995
  • The thermal stress distribution of WC and Ni binder phases In WC-26st.%Ni and WC-6wt.%Ni composites has been investigated over the temperature range 100-900 K using a time-of-flight neutron diffractometer. To determine the stress distribution, the breadths of WC and Ni peaks in the reference powder and the composites were analyzed. The peak breadths were corrected for particle size effect using a procedure based on the integral peak breadth method of particle size-strain analysis. The result shows a broad range of strain, and thus stress, is present in the WC and Ni binder phases of the composites. The strain distribution of both phases broadens as the temperature decreases, and some fraction of total strain distribution of the WC phase remains tensile regardless of the temperature. The strain distribution of the WC phase broadens as the binder content increases, and that of Ni binder phase broadens as the binder content decreases, which means the strain distribution broadens as the absolute value of residual stress increase.

  • PDF

공정, 전압, 온도 보상 회로를 이용한 On-Chip CMOS Oscillator (On-Chip CMOS Oscillator using PVT Compensated Circuit)

  • 한도희;권익진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.593-594
    • /
    • 2008
  • In this article, process voltage temperature (PVT) compensated on-chip oscillator is implemented by using proportional to absolute temperature (PTAT) circuit and process compensator. Process compensator circuit based on current subtracter and PTAT circuit are proposed for compensation of oscillation frequency to cope with process variation and temperature variation. All circuit can operate in the range of $3.5{\sim}5\;V$ supply voltage. It can be applied to PVT insensitive low frequency clock reference generator.

  • PDF

두 개의 온도 의존 매개변수가 있는 3차 상태방정식의 성능비교 (Performance Comparison of Cubic Equations of State With Two Temperature Dependent Parameters)

  • 권영욱;박경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.205-210
    • /
    • 2001
  • Cubic equations of state with two temperature dependent parameters are suggested and optimized using ASHRAE data for methane, propane, carbon dioxide, R-32 and R-134a. Appropriate simple functional forms are assumed for the temperature dependent parameters. The equations tested are Martin, Fuller, Harmens-Knapp, Schmidt-Wenzel. Among them modified Schmidt-Wenzel equation of state appears to be the choice for calculation of saturation properties such as vapor pressures, saturated liquid volumes, and saturated vapor volumes with an average absolute deviation of about one percent over the entire region excluding; the near cirtical.

  • PDF

데시칸트제습기 선정프로그램 (Desiccant Dehumidifier Selection Program)

  • 김희재;박승태;유경록;이현주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.224-229
    • /
    • 2009
  • Performance curve of the desiccant rotor is an important information when developing and selecting the desiccant dehumidifier. The effective utilization of the energy is major capacity for the system and the desiccant performance curve is a design ability for a designer. By the rotor supply contract with DRI, ECO-DRY programs would be offered. Moreover, it could make remarkable progress in the desiccant system and energy saving. It is good to introduce the programs with the amicable help of DRI.

  • PDF

표면온도분포 분석을 이용한 몰드 변압기 진단 (Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution)

  • 임용배;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

저어널베어링의 압력 및 온도분포에 관한 실험적 연구 (An Experimental Study on the Pressure and Temperature Distribution in a Plain Journal Bearing)

  • 신영재;김경웅
    • Tribology and Lubricants
    • /
    • 제4권1호
    • /
    • pp.69-73
    • /
    • 1988
  • The effects of journal speed and bearing load on pressure distribution and the temperature distribution of bearing surface are investigated experimentally. The journal bearing which has 219.94mm diameter, length-to-diameter ratio of L/D=0.8 and clearance ratio of 0.004 is used. Journal has a built-in pressure transducer for the measurement of pressure distribution in the mid plane of bearing. Bearing surface temperatures are measured at 60 points. The bearing load is varied from 300 N to 5900 N and journal speed from 300 rpm to 2500 rpm. As the load is increased under constant speed, the location of maximum pressure moves to the site of minimum film thickness, and maximum pressure and absolute value of minimum pressure are increased. The temperature distribution in vicinity of oil inlet shows that heated lubricant's carry-over exists around the oil inlet.

사출성형조건이 HIPS 수축율에 미치는 영향 (The effect of the injection molding conditions on the shrinkage of HIPS)

  • 차백순;이병옥;최권일;구본흥;박형필
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.259-264
    • /
    • 2005
  • The shrinkage of the product in injection molded part occurs due to the volume change with variation of temperature and pressure and is influenced by the processing conditions of injection molding. Mold designers greatly concerns the shrinkage of parts for a high dimensional accuracy. In this study, bar type HIPS specimen with 15x19 grid on the surface was tested. The amount of shrinkage of flow and transverse directions was examined with respect to the injection molding conditions such as melt temperature, injection speed, holding pressure, mold temperature and cooling time. As the packing pressure increased, the difference of shrinkage of both directions is decreased and the absolute shrinkage value also decreased.