• Title/Summary/Keyword: Abrasion rate

Search Result 168, Processing Time 0.023 seconds

A study of characteristics by abrasion test of recycled aggregates (재생골재의 마모시험과 특성연구)

  • Song Young Joo;Park Kyoung Sub;Kong Kyoung Rok;Kang Heon Chan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.117-120
    • /
    • 2005
  • It is necessary for decrease of building waste to increase using of recycled aggregate. However, the quality of those recycled aggregates is not good enough. This study aim at the rise of the quality through abrasion test and researching the characteristic change of the test. The samples of recycled aggregates had been divided into 10 sorts by the amount of cement paste, and then the abrasion rate of those divided aggregates has been figured out through this experiment. The result of this experiment shows that the quality of the recycled aggregates has been improved.

  • PDF

Wear Behaviors of ${Si_3}{N_4}$ under Various Sliding Conditions (미끄럼 환경의 변화에 따른 ${Si_3}{N_4}$의 마멸거동)

  • Lee, Yeong-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1753-1761
    • /
    • 1996
  • The wear behaviors of ${Si_3}{N_4}$ under the different sliding conditions were investigated. The cylinder-on-disc wear tester was used. Using the servo-metor, the sliding speed did ot alternate due to the frictional forces. Threekinds of loads and speeds were selected to watch the variation of the wear rates and the frictional forces. Also three kinds of sliding condition under a constant speed were used to see the effects of the oxidationand the abrasion. The contact pressure was more effective than the repeated cycle on the wear behavior of ${Si_3}{N_4}$. With the low loads, the effect of the asperity-failure was more dominant than that of oxidation and abrasion. As increasing the load, the effects of oxidation and abrasion were increased, but the asperity-failure effects were decreased. The wear particles destroyed the ozide layers formed on sliding surfaces. The wear rate could be decreased due to delaying the oxidation. The frictional power and the wear weight per time were usefuel to see the transition of wear.

Cure Characteristics, Mechanical Properties, Abrasion Property and Thermal Properties of EVM/EPM Blends Containing Flame Retardants

  • Sung, Il Kyung;Lee, Won Ki;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.52 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • The curing behavior, mechanical properties, hot-air aging resistance, abrasion properties,thermal properties, etc., of EVM/EPM/APP (ammonium polyphosphate)/DPER (dipentaerythritol)/EG (expandable graphite) and EVM/EPM/ATH (aluminium trihydroxide) flame retarding systems in ethylene vinyl acetate rubber (EVM) blends with EPM (ethylene propylene rubber) were sequentially examined. For both flame retarding systems, the torque values increased with the content of EPM rubber and with the vulcanization time. As the content of EPM rubber increased, the scorch time became shorter, whereas the optimum cure time followed an increasing trend. For the EVM/EPM/APP/DPER/EG flameretarding system, as the content of EPM rubber increased, the hardness did not change,whereas the tensile strength and elongation at break decreased. A hot-air aging resistance test at $150^{\circ}C$ showed that the heat resistance decreased with the EPM content regardless of the kinds and contents of flame retardants. As the EPM content increased, the abrasion rate became higher and the abrasion resistance of the EVM/EPM/APP/DPER/EG flame retarding systems exceeded that of the EVM/EPM/ATH flame retarding counterparts. In comparison with the EVM/EPM/ATH flame retarding systems, the thermal stability of the EVM/EPM/APP/DPER/EG flame retarding system showed an increasing tendency.

The Effects of Sb Additions on the Structures and Mechanical Properties of C/V Graphite Cast Iron (C/V 흑연주철(黑鉛鑄鐵)의 조직(組織)과 기계적성질(機械的性質)에 미치는 Sb첨가효과(添加效果))

  • Choi, Yang-Jin;Kang, In-Chan
    • Journal of Korea Foundry Society
    • /
    • v.7 no.1
    • /
    • pp.53-59
    • /
    • 1987
  • In order to study the infuence of Sb addition on the compacted vermicular graphite cast iron(C/V) and gray cast iron(GC), these specimen which had different Sb content(0-0, 1wt.%) were prepared. these specimen were tested for microstructure and mechanical properties. The result from this study are as follows. For C/V and GC, the microstructure of graphite appeared to be finer with increasing Sb content more than 0.06wt.% Ferrite disappeared from the matrix with addition of Sb more than 0.06wt.% in GC and more than 0.08wt.% in C/V. The size of the eutectic cell in GC was 4.5 to 7 times larger than that in C/V, but the decreasing tendancy of its size was more remarkable in GC than in C/V with increasing Sb content. The abrasion speed corresponding to the maximum amount of abrasion in the nabrasion test was found to be 1.37m/sec. GC sample weared 3.6 to 21 times faster than those of C/V did. the amount of abrasion demeased remarkably with Sb addition, and the abrasion rate was constant with Sb content over 0.04wt.%

  • PDF

Effect of Blade Materials on Wear Behaviors of Styrene-Butadiene Rubber and Butadiene Rubber

  • Lee, Gi-Bbeum;Shin, Beomsu;Han, Eunjung;Kang, Dawon;An, Dae Joon;Nah, Changwoon
    • Elastomers and Composites
    • /
    • v.56 no.3
    • /
    • pp.172-178
    • /
    • 2021
  • The wear behavior of styrene-butadiene rubber (SBR) and butadiene rubber (BR) was investigated using a blade-type abrader with a steel blade (SB), Ti-coated tungsten carbide blade (TiB), or zirconia blade (ZB). The wear rate of SBR against SB and TiB decreased with increasing number of revolutions because of the blunting of the blades during wear. However, the wear rate of SBR against ZB remained nearly constant with little blade blunting. Generally, the wear rate of BR was largely unaffected by the blade material used for abrasion. The wear rate and frictional coefficient of SBR were found to be higher than those of BR at similar levels of frictional energy input. A power-law relationship was found between the wear rate and frictional energy input during abrasion. A well-known Schallamach pattern was observed for SBR, while a much finer pattern was observed for BR. The blade material affects the wear rate of the rubbers because the macromolecular free radicals and blade tend to undergo mechano-chemical reactions. The inorganic ZB was found to be the most inert for such a mechanism.

A study on the capability of edge shape milling tool with the operatio parameters of equipment (장비운영요소변화에 따른 석재측면 성형공구의 성능시험 연구)

  • 선우춘
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.332-341
    • /
    • 1998
  • Conventional polishing of stone panel edges has been done by hand. While this has changed somewhat with the advent of automatic machines, it is still very much a hand finishing technology. For the development of edge shape milling tool, the primary test on characteristics of edge shape milling tool was carried out. This paper presents the results of tests focused upon the milling capability that was varied by the variables of operation parameters. Author tried to confirm the effect of six operation parameters of equipment such as rotation speed, advance speed, applied load, water flow rate and rotational direction. The result from test was described in term of shape milling capability that was defined as cutting volume of rock by unit weight of tool wear. The variance of the results could indicate the optimum level of each operating parameters. The test was also carried out to determine the abrasion resistance varied according to the abrasive flow rate. The abrasion resistance was increased with the abrasive flow rate, but over some rate it was not changed.

  • PDF

Treatment of Spontaneous Pneumothorax; in Patients 50 Years of Age or Older (노인성 자연 기흉의 치료방법 및 그 결과;50세 이상환자 60례 대상)

  • 조선환
    • Journal of Chest Surgery
    • /
    • v.26 no.7
    • /
    • pp.532-537
    • /
    • 1993
  • To assess the therapy of spontaneous pneumothorax in the aged patients, the treatment methods and results in 60 patients 50 years of age or older were retrospectively reviewed. Most of the patients were male [56 of 60 patients] and the major underlying lung diseases associated with spontaneous pneumothorax were tuberculosis [32 patients] and chronic obstructive lung disease [20 patients]. The recurrence rate of thoracostomy tube drainage with or without chemical pleurodesis using tetracycline was 39.6% [21 of 53 patients], but there was no recurrence in the patients treated with open thoracotomy, pleural abrasion, and chemical pleurodesis using talcum powder[Asbestosis free]. In the patients treated with open thoracotomy, the bullous or bleb lesions were placed in the various sites of both lungs. We concluded that even though thoracostomy tube drainage is the first choice of therapy for spontaneous pneumothorax in the aged patients, the recurrence rate is high, especially in the patients with persistent air leakage for more than 2 days, and the open thoracotomy with pleural abrasion and chemical pleurodesis using talcum powder can prevent the recurrence in the selected patients.

  • PDF

Effects of Carbide Morphology and Heat Treatment on Abrasion Wear Resistance of Chromium White Cast Irons (합금크롬주철의 탄화물형상 및 열처리가 내마모성에 미치는 영향)

  • Yu, Sung-Kon;Matsubara, Yasuhiro
    • Korean Journal of Materials Research
    • /
    • v.12 no.5
    • /
    • pp.407-413
    • /
    • 2002
  • Eutectic high chromium cast irons containing 17%Cr and 26%Cr were produced for this research by making each of them solidify unidirectionally. Abrasion wear test against SiC or $Al_2$O$_3$bonded paper was carried out using test pieces cut cross-sectionally at several distances from the chill face of castings. The wear resistance was evaluated in connection with the parameters such as eutectic colony size($E_w$), area fraction of boundary region of the colony($S_B$) where comparatively large massive chromium carbides are crystallized and, average diameter of chromium carbides in the boundary region($D_c$). The wear rate($R_w$), which is a gradient of straight line of wear loss versus testing time, was influenced by the type and the particle size of the abrasives. The $R_w$ value against SiC was found to be larger than that against A1$_2$O$_3$under the similar abrasive particle size. In the case of SiC, the $R_w$ value increased with an increase in the particle size. The $R_w$ value also increased as the eutectic colony size decreased, and that of the 17%Cr iron was larger than that of the 26%Cr iron at the same $E_w$ value. Both of the $S_B$ and $D_c$ values were closely related to the $R_w$ value regardless of chromium content of the specimens. The $R_w$ values of the annealed specimens were greater than those of the as-cast specimens because of softened matrix structures. As for the relationship between wear rate and macro-hardness of the specimens, the hardness resulting in the minimum wear rate was found to be at 550 HV30.

Staple Line Coverage with a Polyglycolic Acid Patch and Fibrin Glue without Pleural Abrasion after Thoracoscopic Bullectomy for Primary Spontaneous Pneumothorax

  • Hong, Ki Pyo;Kim, Do Kyun;Kang, Kyung Hoon
    • Journal of Chest Surgery
    • /
    • v.49 no.2
    • /
    • pp.85-91
    • /
    • 2016
  • Background: This study was conducted to determine the efficacy of staple line coverage using a polyglycolic acid patch and fibrin glue without pleural abrasion to prevent recurrent postoperative pneumothorax. Methods: A retrospective analysis was carried out of 116 operations performed between January 2011 and April 2013. During this period, staple lines were covered with a polyglycolic acid patch and fibrin glue in 58 cases (group A), while 58 cases underwent thoracoscopic bullectomy only (group B). Results: The median follow-up period was 33 months (range, 22 to 55 months). The duration of chest tube drainage was shorter in group A (group A $2.7{\pm}1.2day$ vs. group B $3.9{\pm}2.3day$, p=0.001). Prolonged postoperative air leakage occurred more frequently in group B than in group A (43% vs. 19%, p=0.005). The postoperative recurrence rate of pneumothorax was significantly lower in group A (8.6%) than in group B (24.1%) (p=0.043). The total cost of treatment during the follow-up period, including the cost for the treatment of postoperative recurrent pneumothorax, was not significantly different between the two groups (p=0.43). Conclusion: Without pleural abrasion, staple line coverage with a medium-sized polyglycolic acid patch and fibrin glue after thoracoscopic bullectomy for primary spontaneous pneumothorax is a useful technique that can reduce the duration of postoperative pleural drainage and the postoperative recurrence rate of pneumothorax.

The Effect of Thoracoscopic Pleurodesis in Primary Spontaneous Pneumothorax: Apical Parietal Pleurectomy versus Pleural Abrasion

  • Huh, Up;Kim, Yeong-Dae;Cho, Jeong Su;I, Hoseok;Lee, Jon Geun;Lee, Jun Ho
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.316-319
    • /
    • 2012
  • Background: The standard operative treatment of primary spontaneous pneumothorax (PSP) is thoracoscopic wedge resection, but necessity of pleurodesis still remains controversial. Nevertheless, pleural procedure after wedge resection such as pleurodesis has been performed in some patients who need an extremely low recurrence rate. Materials and Methods: From January 2000 to July 2010, 207 patients who had undergone thoracoscopic wedge resection and pleurodesis were enrolled in this study. All patients were divided into two groups according to the methods of pleurodesis; apical parietal pleurectomy (group A) and pleural abrasion (group B). The recurrence after surgery had been checked by reviewing medical record through follow-up in ambulatory care clinic or calling to the patients, directly until January 2011. Results: Of the 207 patients, the recurrence rate of group A and B was 9.1% and 12.8%, respectively and there was a significant difference (p=0.01, Cox's proportional hazard model). There was no significant difference in age, gender, smoking status, and body mass index between two groups. Conclusion: This study suggests that the risk of recurrence after surgery in PSP is significantly low in patients who underwent thoracoscopic wedge resection with parietal pleurectomy than pleural abrasion.