• Title/Summary/Keyword: Abrasion Resistance

Search Result 469, Processing Time 0.037 seconds

COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN (4종의 간접법용 복합 레진의 기계적 특성 비교)

  • Kim, Kil-Soo;Yoon, Tae-Ho;Song, Kwang-Yeob;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

A Study on the Performance Improvement of ta-C Thin Films Coating on Tungsten Carbide(WC) Surface for Aspherical Glass Lens by FCVA Method Compared with Ir-Re coating (Ir-RE 코팅 대비 자장여과필터방식을 이용한 비구면 유리 렌즈용 초경합금(WC)표면의 ta-C 박막 코팅 성능 개선 연구)

  • Jung, Kyung-Seo;Kim, Seung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.27-36
    • /
    • 2019
  • The demand for a low dispersion lens with a small refractive index and a high refractive index is increasing, and accordingly, there is an increasing need for a releasable protective film with high heat resistance and abrasion resistance. On the other hand, the optical industry has not yet established a clear standard for the manufacturing process and quality standards for mold-releasing protective films used in aspheric glass lens molding. Optical lens manufacturers treat this technology as proprietary information. In this study, an experiment was conducted regarding the optimization of ion etching, magnetron, and arc current at each source and filter part, and bias voltage in FCVA (filtered cathode vacuum arc)-based Ta-C thin film coatings. This study found that compared to iridium-rhenium alloy thin film sputtering products, the coating conditions were improved by approximately 50%, 20%, and 40% in terms of thickness, hardness, and adhesive strength of the film, respectively. The thin-film coating process proposed in this study is expected to contribute significantly to the development and utilization of glass lenses, which will help enhance the minimum mechanical properties and quality of the mold-release thin film layer required for glass mold surface forming technology.

Effect of mechanical surface treatment on the fracture resistance and interfacial bonding failure of Y-TZP zirconia (Y-TZP zirconia의 기계적 표면처리가 파절저항과 접착계면 실패에 미치는 영향)

  • Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2014
  • Purpose: Surface damage and bonding strength difference after micromechanical treatment of zirconia surface are to be studied yet. The aim of this study was to evaluate the difference of fracture resistance and bonding strength between more surface-damaged group from higher air-blasting particle size and pressure, and less damaged group. Materials and Methods: Disk shape zirconia ($LAVA^{TM}$) was sintered and air-blasted with $30{\mu}m$ particle size (Cojet), under 2.8 bar for 15 seconds, $110{\mu}m$ particle size (Rocatec), under 2.8 bar for 15 seconds, and $110{\mu}m$ particle size (Rocatec), under 3.8 bar for 30 seconds respectively. Biaxial flexure test and bonding failure load test were performed serially (n = 10 per group). For bonding test, specimens were bonded on the base material having similar modulus of elasticity of dentin with $200{\mu}m$-thick resin cement for tension of surface damage. Failure load of bonding was detected with acoustic emission (AE) sensor. Results: There were no significant differences both in the biaxial flexure test and bonding failure load test between groups (P > 0.05). Sub-surface cracks were all radial cracks except for two specimens. Conclusion: Within the limitations of no aging under monotonic load test, surface damage from higher air-blasting particle size and pressure was not significant. Evaluations of failure load with bonded zirconia disks was clinically relevant modality for surface damage and bonding strength, simultaneously.

AN EVALUATION OF WEAR CHARACTERISTICS OF LIGHT-CURED RESTORATIVE COMPOSITES ON ENAMEL SURFACE (광중합형 복합레진과 법랑질간의 마모특성 평가)

  • Baik, Byeong-Ju;Lee, Seung-Young;Lee, Doo-Cheol;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.261-270
    • /
    • 2001
  • This study was performed to evaluate wear characteristics of light-cured composites when opposed by human enamel. Seven light-cured restorative composites were selected and enamel cusps sectioned from premolars. All samples were stored in distilled water at $37^{\circ}C$ for 10 days. 68.6 N of weight was loaded during the test. The measurements of vertical loss of enamel cusps, weight loss and volume loss of composites, and SEM observations of the polished and abraded surfaces were made after 30,000 cycles. The results obtained were summarized as follows; 1. The highest hardness value of 70.4 was observed in the Spectrum group and the lowest value of 19.8 was observed in the Heliomolar group. Results of Tukey test showed that an overall significant difference was indicated except the Spectrum, Z100 and Clearfil AP-X groups(p<0.05). 2. Enamel showed the good abrasion resistance against the Heliomolar group of microfilled composite and the Palpique Toughwell group containing the submicron hybrid type spherical fillers. 3. The abrasive wear resistance of hybrid composites was improved with the decrease of mean particle size and hybrid of submicron particle fillers. 4. SEM observation of worn surfaces revealed the protrusion, attrition and missing of fillers, cracks developing and delamination in the matrix.

  • PDF

An Experimental Study and Value Analysis for Performance Assessment of the Embo-thane Membrane Waterproofing Method (엘보탄도막방수공법의 성능평가를 위한실험적 연구 및 VE분석)

  • Yoon, Cha-Woong;Lee, Seung-Soo;Kim, Sang-Rok;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.123-134
    • /
    • 2009
  • Since 1970s, urethane waterproofing method is broadly used in rooftops, underground spaces, and sports stadium for its outstanding ultraviolet blockage, watertightness, and elasticity. However, development of slippage-resistance and endurance, improvement of function considering convenience and visually pleasing of users, urethane waterproofing method is necessary, since rooftops and underground spaces have slippage and external force risks. Therefore, many improved waterproofing methods are being developed and, recently, embo-thane waterproofing method, which applies embo-spray coating system, has been developed. This paper explains exposure, nonexposure, and floor-material of embo-thane waterproofing method, and then perform experimental study for comparison with urethane waterproofing method about tensile strength, coefficient of expansion, performance of bond, anti-abrasion, and slippage-resistance. In addition, the performance index was presented for the superiority of embo-thane waterproofing method compared to urethane by setting up evaluation criteria considering not only physical performance but also design side of embo-thane waterproofing method, and Value Analysis applying AHP. Also for an assessment considering uncertain result, Monte Carlo Simulation Method was used to operate reliability analysis through statistic approach method.

ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT (차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Yook, Geun-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.685-695
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four composite resins in an alkaline solution. The resistance to degradation was evaluated on the basis of mass loss(%), degradation depth(${\mu}m$), Si loss(ppm) and wear depth. The brands studied were Heliomolar flow, Filtek supreme, Point4, Tetric flow. The results were as follows: 1. The sequence of the mass loss was in descending order by Heliomolar flow, Filtek supreme, Point4, Tetric flow. There was significant differences among the materials except Heliomolar flow and Filtek supreme. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek supreme, Heliomolar flow, Tetric flow, Point4. There were significant differences among the materials except Heliomolar flow and Tetric flow. 3. The sequence of Si loss was in descending order by Filtek supreme, Heliomolar flow, Point4, Tetric flow. There were significant differences among the materials except Point 4 and Tetric flow. 4. The sequence of maximum wear depth was in descending order by Heliomolar flow, Point4, Fillet supreme, Tetric flow and there was increasing wear depth on soaking in 0.1N NaOH solution. 5. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. There results indicate that wear and hydrolytic degradation could be considered to be evaluation factors of composite resins.

  • PDF

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.

DIMENSIONAL ACCURACY OF EPOXY RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS (EPOXY RESIN의 정확도와 인상재와의 친화성에 관한 연구)

  • Chang, Su-Kyoung;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.383-394
    • /
    • 1999
  • The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has some problems such as the weakness in its strength and low abrasion resistance. Recently, epoxy resin die systems have become available. The purpose of this study was to examine two commercially available resin die systems and evaluate some characteristics for their clinical performance. This study evaluated the dimensional accuracy of epoxy resins and their wettability with impression materials. In this study, the first experiment was about dimensional accuracy of different die materials. The master model was made of stainless steel. 10 models were made of two epoxy resins (Die-epoxy, Tri-epoxy) and a die stone (Fujirock) each. Occlusal diameter (Dimension I), occluso-gingival height (Dimension II), and interabutment distance (Dimension III) were measured in each model. Next, the contact angles of die materials with impression materials were observed. The blocks were made of polyether, hydrophilic additional silicone, polysulfide impression materials. By drop-ping the same amount (0.05ml) of Tri-epoxy, Die-epoxy, and die stone on the blocks, 10 samples of each die material were made. After setting of materials, the contact angles were measured. The results of this study were as follows. 1. The expansion of stone die and the shrinkage of resin dies in occlusal diameter were observed, and stone and Tri-epoxy were expanded and Die-epoxy was shrinked in occluso-gingival height. There was little change among materials in interabutment distance (p<0.05). 2. In comparison with the master model Tri-epoxy had the least variation in measurement of the three die systems examined. Die-epoxy was next, and die stone showed the greatest variation. 3. The compatibility of die stone for polyether, hydrophilic additional silicone, polysulfide decreased in order, wherease epoxy materials had the decreased compatibility for polyether and polysulnde, hydrophilic additional silicone in order. It was not statistically different between polyether and polysulfide (p<0.05). 4. The contact angles of Tri-epoxy, Die-epoxy, die stone were getting bigger in order.

  • PDF

Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle (전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가)

  • Kwak, Daehwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.634-640
    • /
    • 2020
  • Failure analysis and heat-resistant were performed for an electric fuel pump that is installed in the fuel tank to transfer fuel to the engine of combat vehicles. The fuel pump with a DC motor was disassembled and inspected to determine the cause of failure. The failure phenomenon was classified into three categories based on observations of the inside of the housing: burnt winding, quick brush abrasion, and fuel leak into the pump. Based on the inspection results, it was estimated that overheating was the main cause of failure. The thermal test was conducted under the no-load condition in 24 hours, and the thermal sensor was installed on the stator surface and the brush holder to check the possibility of damage to the winding due to overheating. When the ambient temperature of the fuel pump was set to 68 ℃, the stator temperature increased to 135.9 ℃, and the winding of the motor was almost damaged. The test results confirmed the lack of heat resistance of fuel pump windings, and suggested that the type F of insulation class (below 155 ℃) of the windings and varnish should be replaced with type C or higher that can be used above 180 ℃.

Interface Reactions and Diffusion of Si3N4/Ti and Si3N4/TiAl Alloys (Si3N4/Ti와 Si3N4/TiAl합금의 계면반응 및 확산 거동)

  • Choi, Kwang Su;Kim, Sun Jin;Lee, Ji Eun;Park, Joon Sik;Lee, Jong Won
    • Korean Journal of Materials Research
    • /
    • v.27 no.11
    • /
    • pp.603-608
    • /
    • 2017
  • $Si_3N_4$ is a ceramic material attracting attention in many fields because of its excellent abrasion resistance. In addition, Ti and TiAl alloys are metals used in a variety of high temperature environments, and have attracted much attention because of their high strength and high melting points. Therefore, study of the interface reaction between $Si_3N_4/Ti$ and $Si_3N_4/TiAl$ can be a useful practice to identify phase selection and diffusion control. In this study, $Si_3N_4/Ti_5Si_3+TiN/TiN/Ti$ diffusing pairs were formed in the $Si_3N_4/Ti$ interfacial reaction and $Si_3N_4/TiN(Al)/Ti_3Al/TiAl$ diffusion pathway was identified in the $Si_3N_4/TiAl$ interfacial reaction. The diffusion layers of the interface reactions were identified and, to investigate the kinetics of the diffusion layer, the integrated diffusion coefficients were estimated.