• 제목/요약/키워드: Abnormal voltage

검색결과 193건 처리시간 0.024초

마아카-에폭시 복합재료 계면에서의 왜도 특성 (The Skewness Properties at Interface in Mica-Epoxy Composite)

  • 임장섭;이은학;구할본;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 추계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 1992
  • In this paper, the skewness properties of partial discharge at interface layer in mica-epoxy composite material were investigated and studied on interface specimens which has internal electrodes. As a result, it has been confirmed that the interface exists as abnormal resin layer and the contact condition at the interface is depended upon the density of si lane aqueous solution. The Pulse frequency of discharge at abnormal interface has been shown a linear increasing with enlargement of discharge quantity according to rising of the applied voltage. Whereas, in case of normal interface, pulse frequency represented exponential increasing at the saturating point of discharge quantity. The aging model can be represented from the variable characteristics of skewness.

  • PDF

계통사고시 장해 경감을 위한 긴급제어에 관한 연구 (A Study on the Emergency Control Algorithm for Viability Crisis of Power System)

  • 송길영;이희영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.129-132
    • /
    • 1987
  • This paper presents an emergency control algorithms for viability crisis following abnormal condition as well as a sudden major supply outage and line outage. The algorithm considers the effect of voltage-reactive power control for determining the load shedding quantities and generation reallocation. The problem is decomposed into a P-problem and a Q-problem. The former minimizes system frequency deviation from nominal value and the latter minimizes voltages violation of load buses. The optimization problem is solved by a reduced gradient technique which can handle a great number of inequality constraints very efficiently. It has been found that the use of the proposed algorithm for 6-Bus system restore the abnormal system during the viability crisis to the normal state.

  • PDF

HVDC 전력변환기의 Commutation 동작분석 (Analysis of HVDC Converter Commutation Process)

  • 곽주식;우정욱;고봉언;김찬기;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1286-1288
    • /
    • 2000
  • Commutation failure can be considered as the severest abnormal operation of thyristor HVDC converter. During the failure, power conversion from DC to AC is stopped until the AC voltage get recovered. The process of thyristor converter is subscribed at normal and abnormal state, respectively. The detection and the protection for Cheju HVDC are explained by computer simulation results.

  • PDF

비상상태에서의 제주 ±80kV 60MW HVDC 운전 방안 연구 (±80kV 60MW HVDC Operational Strategy in Abnormal State)

  • 윤종수;서보혁
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.664-668
    • /
    • 2012
  • This paper presents the operation strategy of KEPCO(Korea Electric Power COporation) ${\pm}80kV$ 60MW Bipole HVDC system that will be applied between Guemak C/S(converter station) and Hanlim C/S in Jeju island. Unlike intertie HVDC system, this system is located in AC power grid inside. Therefore, the enhancement of system security related with line flow and bus voltages can be major operation strategy. In this paper, in particular, the optimal operation algorithm in the abnormal(not steady state) power system is presented and simulated.

디젤발전기 엔진 상태 진단 기술의 발전소 적용 연구 (A Study on the Power Plant Application of Engine Condition Diagnosis Technology for Diesel Generator)

  • 최광희;이상국
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel generator of nuclear power plant has a role for supply of emergency electric power to protect reactor core system in event of loss of off-site power supply. Therefore diesel generator should be tested periodically to verify the function that can supply specified frequency and voltage at design power level within limited time. For this purpose, appropriate maintenances in case that abnormal conditions were found are required in allowed time. In this paper, results of development of engine condition diagnosis technology and study on power plant of its technology for diesel generator are described.

Analysis of CRUD Flake Applied to Abnormal High Beam Current by Shielded-EPMA

  • Jung, Y.H.;Baik, S.J.;Ahn, S.B.
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.265-271
    • /
    • 2018
  • CRUD specimens, scraped from twice-burned fuel cladding in the Korean Nuclear Power Plant, were analyzed using Shielded-EPMA. The principal elements of the CRUD were identified as Ni and Fe, at an approximate ratio of 1.3 Ni/Fe. To investigate the morphology and composition of the pure metallic materials in the CRUD, coolant impurities must be removed. This can be accomplished by increasing the EPMA current to an abnormally high intensity until the impurities are melted. Normally, EPMA applications are performed at conditions of 20 kV voltage and 20 nA current. But in our study, the applied current was increased up to 1200 nA, over time increments ranging from 5 to 30 seconds. This technique was performed by opening an adjustable aperture for the gun alignment. Results showed impurities contained in the CRUD material disappeared and pure metal materials, e.g., Ni and Fe, remained. This method presents an innovative way to analyze CRUD.

A Novel Quadrant Search Based Mitigation Technique for DC Voltage Fluctuations in Multilevel Inverters

  • Roseline, Johnson Anitha;Vijayenthiran, Subramanian;V., Rajini;Mahadevan, Senthil Kumaran
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.670-684
    • /
    • 2015
  • The hybrid cascaded multilevel inverter (HCMLI) is a popular converter topology that is being increasingly used in high power medium voltage drives. The intricacy of the control technique for a HCMLI increases with the number of levels and due to fluctuating dc voltages. This paper presents a novel offline quadrant search based space vector modulation technique to synthesize a sinusoidal output from a dispersed pattern of voltage vectors due to different voltages in the auxiliary unit. Such an investigation has never been reported in the literature and it is being attempted for the first time. The method suggested distributes the voltage vectors for a reduced total harmonic distortion at minimal computation. In addition, the proposed algorithm determines the maximum modulation index in the linear modulation range in order to synthesize a sinusoidal output for both normal and abnormal vector patterns. It is better suited for a wide range of practical applications. It is particularly well suited for renewable source fed inverters which utilize large capacitor banks to maintain the dc link, which are prone to such slow fluctuations. The proposed quadrant search space vector modulation technique is simulated using MATLAB/SIMULINK and implemented using a Nexys-2 Spartan-3E FPGA for a developed prototype.

$\textrm{I}_{DDQ}$ 테스팅을 위한 빠른 재장형 전류감지기 (Fast built-in current sensor for $\textrm{I}_{DDQ}$ testing)

  • 임창용;김동욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.811-814
    • /
    • 1998
  • REcent research about current testing($\textrm{I}_{DDQ}$ testing) has been emphasizing that $\textrm{I}_{DDQ}$ testing in addition to the logical voltage testing is necessary to increase the fault coverage. The $\textrm{I}_{DDQ}$. testing can detect physical faults other than the classical stuck-at type fault, which affect reliability. One of the most critical issues in the $\textrm{I}_{DDQ}$ testing is to insert a built-in current sensor (BICS) that can detect abnormal static currents from the power supply or to the ground. This paper presents a new BICS for internal current testing for large CMOS logic circuits. The proposed BICS uses a single phase clock to minimize the hardware overhead. It detects faulty current flowing and converts it into a corresponding logic voltage level to make converts it into a corresponding logic voltage level to make it possible to use the conventional voltage testing techniqeus. By using current mirroring technique, the proposed BICS can work at very high speed. Because the proposed BICS almost does not affects normal operation of CUT(circuit under test), it can be used to a very large circuit without circuit partitioning. By altenating the operational modes, a circuit can be $\textrm{I}_{DDQ}$-tested as a kind of self-testing fashion by using the proposed BICS.

  • PDF

냉온정수기의 전원 제어 시스템 개선에 관한 연구 (Research on Improvement of Power Control System of Cold & Hot Water Purifier)

  • 이기연;최충석;김동욱;김향곤;김동우
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.45-50
    • /
    • 2007
  • In this paper, this paper discusses how to improve the power control system of cold and hot water purifiers, in particular, system protecting device against abnormal voltage. The existing power supply control system came with a protecting device composed of varistor device only for impulse-type surges. Even though the existing system senses surge other than impulse-type, the system can not be protected. Accordingly, a new type of power control system was designed to protect the system from surge and ultimately prevent electricity accidents. The power control system suggested in this paper will be designed to protect the system by sensing input voltage and discontinuing power supply by means of SSR if voltage exceeding set value is sensed. To test the designed system, surge was imposed on the existing system and processes of system failure were experimented before safety of the designed power control system was simulated via P-spice program developed by Orcad in order to examine safety and reliability of the system.

리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구 (A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor)

  • 정준채
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.392-401
    • /
    • 2020
  • 연구목적: 본 연구는 비상시의 예비전원장치로 사용 가능한 리튬이온커패시터의 동작 특성을 분석하고, 충·방전시의 선형비례특성을 이용하여 전압을 측정하는 것으로도 예비전원장치의 동작 이상 유무를 판단 할 수 있는 실험근거의 제공을 목적으로 한다. 연구방법: 본 연구를 위한 방법으로 먼저 기존 예비전원장치와 리튬이온커패시터에 대한 동작원리 및 특성을 분석하고, 다음으로 실험에 사용한 유도등의 구성도와 시스템 블록도에 따라 리튬이온커패시터의 전압 측정을 통해 배터리의 보유 전력량을 확인하는 전압대역별 방전전력량 측정 값 테스트와 유도등을 이용한 동작 테스트 실험으로 진행한다. 연구결과: 리튬이온커패시터의 선형비례특성을 이용한 충전전압을 확인하는 것만으로도 정확하게 유도등 램프의 유효동작 시간을 추론 할 수 있는 근거를 제시하고 있다. 결론: 재난 상황 시 리튬이온커패시터를 비상유도등의 예비전원장치로 사용함으로써 비상유도등의 완전 방전을 미연에 방지하고, 예비전원장치의 정상 작동 수행의 문제가 발생하지 않게 하며, 간단한 전압측정만으로도 예비전원장치의 이상 유무를 확인 할 수 있게 하여 향후 피난설비 적용에 많은 활용도를 제시하고자 하였다.