• Title/Summary/Keyword: Abnormal voltage

Search Result 192, Processing Time 0.02 seconds

A Study on Bypass Characteristics for Photovoltaic Module (태양광모듈 바이패스 특성에 관한 연구)

  • Chae, Myoung-Suk;Suh, Hun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.79-80
    • /
    • 2014
  • In this paper, to make sure that the photovoltaic solar cell module of the system can be normal for output in each solar cell module, input and output unit is installed in the bypass device, and then through the voltage and current monitoring to determine abnormality of the solar cell module, in the case of abnormal occurring, the bypass device can be pass to the next solar module of the serial structure.

  • PDF

The Problems and Solutions for 154kV Power Transformer neutral point Ground (154kV 송수전용 변압기 중성점 접지시 문제점과 해결방안)

  • Jeon, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.37-39
    • /
    • 2004
  • To restrain abnormal voltage and effective operation in protect system, some of customer in Korea earth their own transformer in 154kV power system. The above ground system has some problems if ground fault occurs in other related area such as ground relay errors, under count register in two element register system. There for most huge customers opens the ground neutral and it causes errors in insulate and protection coordination and register system. In this paper presents the solution for above system.

  • PDF

A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices (저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.

A Stuty of Programmed Ignition Method for Metal Halide Lamp (메탈핼라이드 램프의 프로그램된 이그니션 방식 연구)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jung, Bong-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.181-183
    • /
    • 2009
  • This paper proposes a programmed ignition method of high frequency electronic ballast for metal halide lamp. The method precisely controls the ignition voltage and prevents possible damage of ballast for abnormal lamp operation or lamp failure, also sures the zero voltage switching. This improved performance for igniting the lamp enables reliable product of high frequency ballast because of high efficiency, fast start and no extra ignitor.

  • PDF

Analysis of closing surge in static condenser bank using EMTP (EMTP를 이용한 스타콘뱅크의 투입써-지 해석)

  • Won, Young-Jin;Seo, Soon-Gyo;Jung, Tay-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.673-675
    • /
    • 1992
  • The operation of condenser-bank is now increasing around Kyoungin area. The operation of condenser-bank is used for the improvement of under voltage and expand of power demand. But the operation has the problem in itself as the switching over voltage. This report deals with the static-condenser fault caused by abnormal operation of circuit breaker which has occurred last summer. We have analyzed this fault using EMTP(electromagnetic transient program).

  • PDF

A Basic Study on Electrostatic Induction Motor (II) (정전(靜電) 유도형(誘導型)모터의 기초연구(基礎硏究)(II))

  • Moon, Jae-Duk;Lee, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.699-702
    • /
    • 1992
  • A miniature size electrostatic induction motor have been constructed and studied by applying a three phase ac power source with a maximum voltage of 5 KV and a variable frequency ranged 0.0 - 150 Hz. A maximum no load speed of the motor tested was about 7600 RPM at the applied voltage of 4330 volt and the frequency of 130 Hz for the case of the rotor surface material of polyprophylene sheet screen-printed $TiO_2$ powder on it. It is found that there are 3 different regions of the motor operation, a rotor stop region, a stable operation region and a high speed abnormal region. And it is also found that the motor speed is influenced greatly by the charge relaxation time constant of the rotor surface materials, which however was changed by the means of vapour-deposited Ti or Ni and screen-printed $TiO_2$ powder on the surface of the rotor material, polyprophylene.

  • PDF

A Study on the Optimal Load Shedding Considering Alleviation of the Line Overload (선로과부하해소를 고려한 최적부하간단에 관한 연구)

  • 송길영;이희영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.6
    • /
    • pp.381-389
    • /
    • 1987
  • This paper presents a method for optimal load shedding in preserving a system security following abnormal condition as well as a sudden major supply outage. The method takes account of static characteristic of generators control and voltage and system frequency characteristic of loads. The optimization problem is solved by a gradient technique to get the maximal effect by the least quantity of load shedding considering line overloads as well as voltage disturbances and system frequency. The method is illustrated on a 8-bus system. It has been found that the use of the proposed algorithm for model systems alleviate the line overload more efficiently than the former method. It is believed that this method will be useful in security studies and operational planning.

  • PDF

Conduction Mechanism Analysis of Low Voltage ZnO Varistor

  • Jang, Kyung-Uk;Kim, Myung-Ho;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.263-266
    • /
    • 1998
  • ZnO varistors have an excellent non-linearity and a large surge-energy absorption capability. For these reasons, the ZnO varistors are widely used to protect electrical/electronic circuits from an abnormal surge and/or noise signal. In order to obtain the low-voltage varistor with randomly distributed large seed grain within bulk, the ZnO varistors are made by a new three-composition seed grain method. And a conduction mechanism of varistors, which was observed in the temperature range of 30 ∼ 120$^{\circ}C$ and at the current range of 10$\^$-8/∼10$^2$ A/cm$^2$, was classified by the three regions of different mechanism when the current was increased.

  • PDF

Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement (음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF

Study on the Failure Protection Mechanism for the Low Voltage Converter Module of Power Control and Distribution Unit (전력조절분배기 저전압 컨버터 모듈의 고장 방지에 대한 연구)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jang, Sung-Soo;Lee, Sang-Kon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.285-288
    • /
    • 2008
  • Even though many modular converters have several internal protection circuit blocks for various abnormal operation conditions, there are many failure cases on modular converters at real applications. In this paper, the control strategy for failure protection of converters with internal 'In-Hibit' function is investigated. As an example, for the MDl modular converters the in-hibit function application is realized and the test results shows that adopting in-hibit function while converter switching reduces the voltage and current stress. And the reduction of switching stress on converter will decrease failure rate on converters.

  • PDF