• Title/Summary/Keyword: Abnormal value detection

Search Result 94, Processing Time 0.029 seconds

Ultrasonic Inspection of Internal Defects of Potatoes (초음파를 이용한 감자의 내부결함검사)

  • Kim, In-Hoon;Jung, Kyu-Hong;Jang, Kyung-Young;Seo, Ryun;Kim, Man-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.82-88
    • /
    • 2003
  • The nondestructive internal quality evaluation of agricultural products has been strongly required from the needs for individual inspection. Recently, the ultrasonic wave has been considered as a solution fur this problem, and an ultrasonic system was constructed for the ultrasonic NDE of fruits and vegetables in our previous work. In this paper, the practical applicability of our ultrasonic system is tested fur the inspection of internal defects (central cavity) in Atlantic potato. Sound speed and RMS of transmitted ultrasonic wave signal were measured and classification algorithm using 2 dimensional stochastic analysis. was presented. Experimental results showed greater value of sound speed and RMS (root mean square) of transmitted signal in normal samples than in abnormal samples with cavity. Also a stochastic method to distinguish normal and abnormal showed fault detection rate less than 5%.

Extended use of P504S Positive Primary Circulating Prostate Cell Detection to Determine the Need for Initial Prostate Biopsy in a Prostate Cancer Screening Program in Chile

  • Murray, Nigel P.;Reyes, Eduardo;Fuentealba, Cynthia;Jacob, Omar;Orellana, Nelson
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9335-9339
    • /
    • 2014
  • Background: To determine the frequency of primary circulating prostate cells (CPC) detection according to age and serum PSA levels in a cohort of men undergoing screening for prostate cancer and to determine the diagnostic yield in those men complying with the criteria for prostate biopsy. Materials and Methods: A prospective study was carried out to analyze all men evaluated in a hospital prostate cancer screening program. Primary CPCs were obtained by differential gel centrifugation and detected using standard immunocytochemistry using anti-PSA, positive samples undergoing a second process with anti-P504S. A malignant primary CPC was defined as PSA+ P504S+, and a test positive if 1 cell/4ml was detected. The frequency of primary CPC detection was compared with age and serum PSA levels. Men with a PSA >4.0ng/ml and/or abnormal rectal examination underwent 12 core prostate biopsy, and the results were registered as cancer/no-cancer and compared with the presence/absence of primary CPCs to calculate the diagnostic yield. Results: A total of 1,117 men participated; there was an association of primary CPC detection with increasing age and increasing serum PSA. Some 559 men underwent initial prostate biopsy of whom 207/559 (37.0%) were positive for primary CPCs and 183/559 (32.0%) had prostate cancer detected. The diagnostic yield of primary CPCs had a sensitivity of 88.5%, a specificity of 88.0%, and positive and negative predictive values of 78.3% and 94.9%, respectively. Conclusions: The use of primary CPCs for testing is recommended, since its high negative predictive value could be used to avoid prostate biopsy in men with an elevated PSA and/or abnormal DRE. Men positive for primary CPCs should undergo prostate biopsy. It is a test that could be implemented in the routine immunocytochemical laboratory.

A Study on the Detection Technique of the Flame and Series arc by Poor Contact (접촉 불량에 의한 불꽃 및 직렬아크의 검출 기법에 관한 연구)

  • Woo, Kim Hyun;Hyun, Baek Dong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.24-30
    • /
    • 2012
  • This study is on the method of the detection for flame and series arc which can be happened at poor contact point added a vibration in part of contact point of low voltage line. In general, the causes of electric fire are over current, short circuit, poor contact, ect. The over-current or short circuit among those causes is detected by measuring a instant current value, but poor contact is difficult to detect by measuring a excessive value of the voltage and current and a distortion of waveforms. And therefore, in this paper, it is studied on the optimal technique of the arc judgement using fuzzy logic and MDET (Multi Dimension Estimation Technique). And it carries out the simulation for arc detection and the experiment for controller and load test. In result, the controller and detection algoristhm, is classified with normal wave and abnormal arc wave without relation with each loads and so the controller can detect a series arc successfully.

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

The Value of I-Scan Image-Enhanced Endoscopy in the Diagnosis of Vocal Cord Leukoplakia

  • Lee, Young Chan;Eun, Young-Gyu;Park, Il-Seok
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.29 no.2
    • /
    • pp.98-102
    • /
    • 2018
  • Background and Objectives : Detection of vascular abnormalities in vocal cord (VC) leukoplakia is important for the diagnosis of neoplastic change of the mucosa. The aim of this study was to investigate the value of i-scan in the differential diagnosis of VC leukoplakia based on visualization of abnormal vascular features. Material and Methods : Fifty-two patients with leukoplakia were enrolled in the study. Images of their larynx obtained using conventional white light endoscopy and an i-scan-enhanced endoscopy (Pentax DEFINA EPK-3000 Video Processors, with Pentax VNLJ10) were reviewed. The microvascular features of the lesions and vascular changes were analyzed and the results were compared with the histopathologic diagnosis. Results : Among the 52 leukoplakia patients, 7 (13.5%) patients had squamous hyperplasia, 10 (19.3%) mild dysplasia, 2 (3.8%) moderate dysplasia, 14 (26.9%) severe dysplasia, 4 (7.7%) carcinoma in situ, and 15 (28.8%) invasive squamous cell carcinoma on histopathologic examination. Using i-scan-enhanced endoscopy, abnormal vascular change with neoplastic neoangiogenesis was detected in most cases of malignant VC lesion [severe dysplasia : 9/14 (64.3%), carcinoma in situ: 2/4 (50.0%), and invasive squamous cell carcinoma : 11/15 (73.4%)]. Conclusion : i-scan-enhanced endoscopy is a useful optical technique for the diagnosis of VC leukoplakia. Our results suggest that i-scan may be a promising diagnostic tool in the early detection of laryngeal cancer.

Visual Evoked Potentials in Retrochiasmal Lesion; Correlation with Neuroimaging Study (시각유발전위 검사상 후-시신경교차부위병변을 보인 환자들의 뇌 영상 결과와의 연관성)

  • Kim, Sung Hun;Cho, Yong-Jin;Kim, Ho-Jin;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • Background and Objective : Visual evoked potentials(VEPs) is considered to be a reliable diagnostic procedure for examining patients with anterior visual pathways. Some abnormalities in the recordings on monocular stimulation have been said to indicate retrochiasmal lesion, but less consistent results have been reported. This study is to evaluate the positive predictability of VEP for the detection of retrochiasmal lesion. Methods : We reviewed VEPs that could be interpreted as indicative of a retrochiasmal lesions, based on amplitude or latency asymmetry recorded on the left(O1) and right(O2) occipital regions. Bilateral absent VEPs on both recording(O1 and O2) without evidence of prechiasmal lesion were included. During 5 years, we identified 31 patients who met the above criteria and who had undergone magnetic resonance imaging(MRI) of brain(one patient underwent computerized tomography). Twenty three patients underwent pattern reversal VEPs and others underwent flash goggle VEPs. Results : Brain imagings were abnormal in 29 and were normal in 2. Of the 29 abnormal scans, lesions in posterior visual pathway were detected in 21 scans(predictive value=68%). The predictive value was not significantly different between flash goggle VEP(75%) and pattern reversal VEP(68%). The predictive value was higher in patient with visual field defect(100%) than those without visual field defect(25%). The pathologic nature of lesion also showed close relations to the predictive value. VEPs is usually paradoxically lateralized(78%), but not in all patients. Conclusion : VEPs abnormalities suggesting retrochiasmal lesion were usually corresponded with brain MRI findings. Diagnostic reliability could be increased when considering the visual field defect and nature of lesion. Therefore, the authors suggest that VEPs studies could be useful in evaluating the patients with the retrochismal lesion.

  • PDF

Tension Wire Sensor of shallow failure detection for the real time slop stabilization (지표변위 감지 센서를 활용한 사면 안전감지 시스템)

  • 장기태;윤기재;정성윤;유병선;김경태;이원효
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10c
    • /
    • pp.19-27
    • /
    • 2001
  • Early detection of premonitory symptom of slope movement ensures tremendous saving of lives and repair costs from catastrophic disaster. Therefore, it is essential to constantly monitor the performance and integrity of both reinforced and un-reinforced cut slopes. We developed a novel monitoring system by using tension wire sensors. It's advantages are highly sensitivity, simple installation, large displacement measurement, durability of system, capability of remote sensing. Real-time measurement of slope surface movement is shown graphically and it gives a warning when the monitored value exceeds a given threshold level so that any sign of abnormal slope movement can be easily perceived.

  • PDF

A Study on the Detection of the Ventricular Fibrillation based on Wavelet Transform and Artificial Neural Network (웨이브렛과 신경망 기반의 심실 세동 검출 알고리즘에 관한 연구)

  • Song Mi-Hye;Park Ho-Dong;Lee Kyoung-Joung;Park Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.780-785
    • /
    • 2004
  • In this paper, we proposed a ventricular fibrillation detection algorithm based on wavelet transform and artificial neural network. we selected RR intervals, the 6th and 7th wavelet coefficients(D6, D7) as features for classifying ventricular fibrillation. To evaluate the performance of the proposed algorithm, we compared the result of the proposed algorithm with that of fuzzy inference and fuzzy-neural network. MIT-BIH Arrhythmia database, Creighton University Ventricular Tachyarrhythmia database and MIH-BIH Malignant Ventricular Arrhythmia database were used as test and learning data. Among the algorithms, the proposed algorithm showed that the classification rate of normal and abnormal beat was sensitivity(%) of 96.10 and predictive positive value(%) of 99.07, and that of ventricular fibrillation was sensitivity(%) of 99.45. Finally. the proposed algorithm showed good performance compared to two other methods.

Tension Wire Sensor of shallow failure detection for the real time slop stabilization (지표변위 감지 센서를 활용한 사면 안전감지 시스템)

  • Chang, Ki-Tae
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.137-143
    • /
    • 2005
  • Early detection of premonitory symptom of slope movement ensures tremendous saving of lives and repair costs from catastrophic disaster. Therefore, it is essential to constantly monitor the performance and integrity of both reinforced and un-reinforced cut slopes. We developed a novel monitoring system by using tension wire sensors. It's advantages are highly sensitivity, simple installation, large displacement measurement, durability of system, capability of remote sensing. Real-time measurement of slope surface movement is shown graphically and it gives a warning when the monitored value exceeds a given threshold level so that any sign of abnormal slope movement can be easily perceived.

  • PDF

Robust Model Based Fault Detection of EPB System for Varying Temperature (온도변화에 강인한 EPB 시스템의 모델기반 고장검출 방법)

  • Moon, Byoung-Joon;Park, Chong-Kug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.26-30
    • /
    • 2009
  • In this paper, a robust model based fault detection for varying temperature is proposed, To develop a robust force estimation model, it needs temperature information because the force sensor's output is affected by a temperature variation. If an EPB system does not include a temperature sensor, the model has a much larger error than an EPB system with a built-in temperature sensor. Therefore, the temperature is estimated by using Ohm's law. The force model is applied with a motor current, battery voltage, operation mode, and the estimated temperature to detect a force sensor's abnormal signal fault. The residual is calculated by comparing the value of the measured force and the estimated force. Fault information is collected by using the output of the evaluated residual with the adaptive thresholds. A proposed robust model based fault detection for varying temperature was verified by HILS (Hardware in the Loop Simulation).