• Title/Summary/Keyword: Abnormal value detection

Search Result 94, Processing Time 0.025 seconds

A Study on Dual-IDS Technique for Improving Safety and Reliability in Internet of Things (사물인터넷 환경에서 안전성과 신뢰성 향상을 위한 Dual-IDS 기법에 관한 연구)

  • Yang, Hwanseok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.1
    • /
    • pp.49-57
    • /
    • 2017
  • IoT can be connected through a single network not only objects which can be connected to existing internet but also objects which has communication capability. This IoT environment will be a huge change to the existing communication paradigm. However, the big security problem must be solved in order to develop further IoT. Security mechanisms reflecting these characteristics should be applied because devices participating in the IoT have low processing ability and low power. In addition, devices which perform abnormal behaviors between objects should be also detected. Therefore, in this paper, we proposed D-IDS technique for efficient detection of malicious attack nodes between devices participating in the IoT. The proposed technique performs the central detection and distribution detection to improve the performance of attack detection. The central detection monitors the entire network traffic at the boundary router using SVM technique and detects abnormal behavior. And the distribution detection combines RSSI value and reliability of node and detects Sybil attack node. The performance of attack detection against malicious nodes is improved through the attack detection process. The superiority of the proposed technique can be verified by experiments.

Anal Papanicolaou Smear in Women with Abnormal Cytology: a Thai Hospital Experience

  • Sananpanichkul, Panya;Pittyanont, Sirida;Yuthavisuthi, Prapap;Thawonwong, Nutchanok;Techapornroong, Malee;Bhamarapravatana, Kornkarn;Suwannarurk, Komsun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1289-1293
    • /
    • 2015
  • Background: Anal intraepithelial lesions (AIL) are likely to represent a precursor for anal cancer. Women infected with human immunodeficiency virus (HIV) may be at higher risk of anal cancer but a screening program for AIL still is not routinely recommended. We here studied the relationship of dysplastic cells from cervical and anal cytology in HIV-infected women. Materials and Methods: This prospective study was conducted in Prapokklao Hospital, Thailand during 2013-2014. Five hundred and ninety nine HIV-infected women were recruited. Participants who had cytological reports of equally or over "abnormal squamous/glandular cells of undetermined significance" (ASC-US) were classified as abnormal cervical or anal cytology. Descriptive statistics and logistic regression analysis were used to evaluate correlations between groups. Results: HIV-infected women with abnormal cervical cytology had 3.8 times more risk (adjusted odd ratio 3.846, 95% confidence interval 1.247-11.862, p-value. 019) for abnormal anal cytology. The major problem of the anal Pap test in this study was the inadequacy of the collected specimens for evaluation (34.4%, 206/599). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of cervical and anal Pap tests were 93.9/12.0, 87.3/96.9, 39.7/21.4, 99.4/94.1 and 88.1/91.4 percent, respectively. Conclusions: Abnormal cervical cytology in HIV-infected women indicates elevated risk for abnormal anal cytology. The sensitivity of the anal Pap test for detection of AIL 2/3 in HIV-infected women was quite low while specificity was excellent. Inadequacy of specimen collection for evaluation was a major limitation. Improvement of sample collection is recommended for future investigations.

Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology

  • Tanabodee, Jitraporn;Thepsuwan, Kitisak;Karalak, Anant;Laoaree, Orawan;Krachang, Anong;Manmatt, Kittipong;Anontwatanawong, Nualpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7381-7384
    • /
    • 2015
  • This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

A Non-annotated Recurrent Neural Network Ensemble-based Model for Near-real Time Detection of Erroneous Sea Level Anomaly in Coastal Tide Gauge Observation (비주석 재귀신경망 앙상블 모델을 기반으로 한 조위관측소 해수위의 준실시간 이상값 탐지)

  • LEE, EUN-JOO;KIM, YOUNG-TAEG;KIM, SONG-HAK;JU, HO-JEONG;PARK, JAE-HUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.4
    • /
    • pp.307-326
    • /
    • 2021
  • Real-time sea level observations from tide gauges include missing and erroneous values. Classification as abnormal values can be done for the latter by the quality control procedure. Although the 3𝜎 (three standard deviations) rule has been applied in general to eliminate them, it is difficult to apply it to the sea-level data where extreme values can exist due to weather events, etc., or where erroneous values can exist even within the 3𝜎 range. An artificial intelligence model set designed in this study consists of non-annotated recurrent neural networks and ensemble techniques that do not require pre-labeling of the abnormal values. The developed model can identify an erroneous value less than 20 minutes of tide gauge recording an abnormal sea level. The validated model well separates normal and abnormal values during normal times and weather events. It was also confirmed that abnormal values can be detected even in the period of years when the sea level data have not been used for training. The artificial neural network algorithm utilized in this study is not limited to the coastal sea level, and hence it can be extended to the detection model of erroneous values in various oceanic and atmospheric data.

Detecting Abnormal Human Movements Based on Variational Autoencoder

  • Doi Thi Lan;Seokhoon Yoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.94-102
    • /
    • 2023
  • Anomaly detection in human movements can improve safety in indoor workplaces. In this paper, we design a framework for detecting anomalous trajectories of humans in indoor spaces based on a variational autoencoder (VAE) with Bi-LSTM layers. First, the VAE is trained to capture the latent representation of normal trajectories. Then the abnormality of a new trajectory is checked using the trained VAE. In this step, the anomaly score of the trajectory is determined using the trajectory reconstruction error through the VAE. If the anomaly score exceeds a threshold, the trajectory is detected as an anomaly. To select the anomaly threshold, a new metric called D-score is proposed, which measures the difference between recall and precision. The anomaly threshold is selected according to the minimum value of the D-score on the validation set. The MIT Badge dataset, which is a real trajectory dataset of workers in indoor space, is used to evaluate the proposed framework. The experiment results show that our framework effectively identifies abnormal trajectories with 81.22% in terms of the F1-score.

Z-score Based Abnormal Detection for Stable Operation of the Series/Parallel-cell Configured Battery Pack (직병렬조합 배터리팩의 안전운용을 위한 Z-score 기반 이상 동작 검출 방법)

  • Kang, Deokhun;Lee, Pyeong-Yeon;Kim, Deokhan;Kim, Seung-Keun;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.390-396
    • /
    • 2021
  • Lithium-ion batteries have been designed and used as battery packs with series and parallel combinations that are suitable for use. However, due to its internal electrochemical properties, producing the battery's condition at the same value is impossible for individual cells. In addition, the management of characteristic deviations between individual cells is essential for the safe and efficient use of batteries as aging progresses with the use of batteries. In this work, we propose a method to manage deviation properties and detect abnormal behavior in the configuration of a combined battery pack of these multiple battery cells. The proposed method can separate and detect probabilistic low-frequency information according to statistical information based on Z-score. The verification of the proposed algorithm was validated using experimental results from 10S3P battery packs, and the implemented algorithm based on Z-score was validated as a way to effectively manage multiple individual cell information.

Design and Evaluation of a Rough Set Based Anomaly Detection Scheme Considering Weighted Feature Values (가중 특징 값을 고려한 러프 집합 기반 비정상 행위 탐지방법의 설계 및 평가)

  • Bae, Ihn-Han;Lee, Hwa-Ju;Lee, Kyung-Sook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.8
    • /
    • pp.1030-1036
    • /
    • 2006
  • The rapid proliferation of wireless networks and mobile computing applications has changed the landscape of network security. Anomaly detection is a pattern recognition task whose goal is to report the occurrence of abnormal or unknown behavior in a given system being monitored. This paper presents an efficient rough set based anomaly detection method that can effectively identify a group of especially harmful internal masqueraders in cellular mobile networks. Our scheme uses the trace data of wireless application layer by a user as feature value. Based on the feature values, the use pattern of a mobile's user can be captured by rough sets, and the abnormal behavior of the mobile can be also detected effectively by applying a roughness membership function considering weighted feature values. The performance of our scheme is evaluated by a simulation. Simulation results demonstrate that the anomalies are well detected by the method that assigns different weighted values to feature attributes depending on importance.

  • PDF

Clinical implications of DMSA Scan in Childhood Acute Pyelonephritis

  • Huh, Sun-Mi;Park, Bo-Kyoung;Kang, Hyun-Mi;Rhim, Jung-Woo;Suh, Jin-Soon;Lee, Kyung-Yil
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.107-113
    • /
    • 2017
  • Purpose: This study aimed to evaluate the relationships between 99mTecnicium-dimercaptosuccinic acid (DMSA) scan findings and clinical parameters including age and fever duration. Methods: The positive rates for abnormal DMSA scans were analyzed according to the age of patients, fever duration prior to admission, and total fever duration. DMSA scan findings were divided into 3 categories: single defect, multifocal defects, and discrepant defects. We evaluated the detection rates of vesicoureteral reflux according to DMSA scan lesions. Results: Among a total 320 cases, 141 (44.1%) had abnormal DMSA scans. The infant group (0-1 year of age) had a shorter total fever duration, and a lower C-reactive protein (CRP) value and DMSA positive rate (39.8% vs. 60.6%, P=0.002) compared to children group (2-15 years of age). Patients with abnormal scans had a longer total fever duration and higher CRP compared to those with normal scans. The positivity rate of abnormal scans did not differ between the patients with a short fever duration prior to admission of ${\leq}2$ days and those with longer fever duration of ${\geq}3$ days. However, patients with longer total fever duration had a higher rate of abnormal DMSA scans (P=0.02). Among cases with a single defect, multifocal defects, and discrepant defects, vesicoureteral reflux was observed in 22.4%, 60% and 70.6% of cases, respectively (P=0.004). Conclusion: Although DMSA scan has limitations in early diagnosis, DMSA scan findings may aid in the prediction of the severity of systemic inflammation and detection of vesicoureteral reflux.

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.