• Title/Summary/Keyword: Abnormal Wear

Search Result 85, Processing Time 0.026 seconds

Design of Infants Natural Colour Fashion Products Using Eckloinia cava and Onion Shell Extracts (제주감태와 양파껍질 추출물을 이용한 유유아(乳幼兒) 천연염색 패션제품 디자인)

  • Jang, Hyun-Joo
    • Fashion & Textile Research Journal
    • /
    • v.21 no.6
    • /
    • pp.708-716
    • /
    • 2019
  • This study explored Jeju natural resources with healing function and tried mixed dyeing of Ecklonia cava and onion shell to improve dyeing. The results showed that silk dyed with a mixture of Ecklonia cava powder and onion shells rather than Jeju's individually dyed silk had better color power to develop fashion products. In addition, all friction lightning bolts, dry cleaning and sweat mining levels were excellent as well as excellent UV protection rates. The three baenaet jeogori worn during a birth anniversary and four rest suits that infants and children can wear comfortably maintained the dyeing and functioning of Ecklonia cava and onion shell mixture that was proven through abnormal experiments. For the three baenaet jeogori and two rest suits, the company has developed a fashion product recognized for high value-added merchandise using a variegation dyeing method made in a handmade style for expressing a person's natural sensibility through dyeing fabrics. Based on the results of the above research, it is expected that various fashion product developments will be possible by dyeing a mixture of functional and colorful extracts of the drug and colorful dye.

A Study on the Slacks Blocks for the Menopausal Women (폐경기 여성을 위한 슬랙스 패턴에 관한 연구)

  • Park, Hyun-Sook;Kim, Yeo-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.19 no.1
    • /
    • pp.145-155
    • /
    • 2008
  • From the menopause, women's aging progress is accelerated. Changes of lower body somatotype are accentuated in abnormal of body index and proportion. The purpose of this study is making more functional, more beautiful and more comfortable slacks for the postmenopausal women who actively participate in social activities. The results of this study are as follows: As the characteristics of this study pattern, hip circumference was replaced with maximum lower body circumference, the crotch length was defined as H/4, front crotch extension was H/16 and back crotch extension was defined as H/8. The center backline was set up with half of crotch level line. As characteristics of style, waist line is lowered 2cm at the center front, 1cm at the center back with a little bent waistband. Knee line was set up heightened 6cm from crotch level to the ancle, and widened the width of the knee and ancle, and made in semi bell bottom. 6 women who put on slacks designed from their body size evaluated that their experimental slacks were superior than ready to wear.

  • PDF

Development of the Auto-Aging Test Controller for a Hydraulic Motor (유압모터 길들이기 자동시험 제어기 개발)

  • Jung, Gyu Hong;Shin, Dae Young;Seo, Dong Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.28-34
    • /
    • 2015
  • Because heavy-duty construction vehicles such as excavators are required for good engine-room cooling capacity, a hydraulic gear motor is adopted in the cooling fan drive mechanism to actively control the output speed, instead of adopting the conventional ON/OFF type belt drive. While gear motors are normally limited to 140bars of operating pressure, those for the cooling fan are capable of operating at continuous pressures of up to 220bars. After assembly, all gear motors for high pressure must pass an aging test which is a kind of the wearing process between the gear teeth and motor housing. During the aging process with gradual pressure increments, gear sticking sometimes occurs due to abnormal wear, resulting in defects. This paper focuses on a gear-sticking free aging test controller that is designed together with the knowledge of an experienced operator and the analysis results of experimental data of the gear jamming phenomenon. From the aging experiment, it is demonstrated that the developed controller that can alter the setting pressure of the load pump is effective for stabilizing the abrupt increase in the motor input pressure, thus preventing the hydraulic motor from stopping. This is expected to be helpful for the reduction of defects and increase in productivity.

Utilizing Advanced Pad Conditioning and Pad Motion in WCMP

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.171-175
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectrics and metal, which can apply to employed in integrated circuits for sub-micron technology. Despite the increased use of CMP process, it is difficult to accomplish the global planarization of free-defects in inter level dielectrics and metal. Especially, defects like (micro-scratch) lead to severe circuit failure, and affects yield. Current conditioning method - bladder type, orbital pad motion- usually provides unsuitable pad profile during ex-situ conditioning near the end of pad life. Since much of the pad wear occurs by the mechanism of bladder type conditioning and its orbital motion without rotation, we need to implement new ex-situ conditioner which can prevent abnormal regional force on pad caused by bladder-type and also need to rotate the pad during conditioning. Another important study of ADPC is related to the orbital scratch of which source is assumed as diamond grit dropped from the strip during ex-situ conditioning. Scratch from diamond grit damaged wafer severely so usually scraped. Figure 1 shows the typical shape of scratch damaged from diamond. e suspected that intensive forces to the edge area of bladder type stripper accelerated the drop of Diamond grit during conditioning. so new designed Flat stripper was introduced.

  • PDF

A Study Temperature of Break Disc using Two-way Layout (이원 배치법을 이용한 브레이크 디스크의 온도에 관한 연구)

  • Ryu, Mi-Ra;Choi, Ji-Woong;Lee, Dae-Hee;Lee, Seong-Beom;Park, Jeong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.94-99
    • /
    • 2012
  • Due to economic growth, the number of cars has grown rapidly and consequently traffic accidents have grown in direct ratio. This reminds us that braking device of a vehicle is an important factor to prevent traffic accidents. Aim these researches to speed and lighten the braking system of vehicles, to lengthen its durability and to shorten the stopping distance. However, it is still difficult to analyze quantitatively and clearly the reason and solution for abnormal wear of disc and pad or judder in flywheel mode. Therefore this study was carried out to presume for mutual relation of analysis condition to get the optimum temperature by two-way layout. The results shown that coefficient of determination has a fine reliability over 92.57% and temperature is made by two-way layout.

A Experimental Study on Wearing Phenomenon of Cu-type Wearing Slider for the Rail Motor Car's Pantograph (집전장치용 동계 주습판의 마모현상에 관한 실험적 연구)

  • Kim, Kyung-Seob
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.3
    • /
    • pp.224-230
    • /
    • 2012
  • The wearing slider of the rail motor car's pantograph is considerable changed by the type and the material properties. Especially, precipitation and arc influences are main factors decided to life time of wearing slider and contact wire. This study is wearing phenomenon analysis of Cu-type wearing slider with high electric conductivity and resistance arc through experiment by running train. Author observed that wearing phenomenon of Cu-type wearing slider with normal and abnormal wearing characteristics and comparatively analysis precipitation, mileage and weight influences of exchanged Cutype and Fe-type wearing sliders. In this paper result showed that necessity for the application which is the Fe-type of wearing slider had superior wear resisting capacity etc., through tribology approach.

Grinding Characteristics of Diamond Burs in Dentistry (치과용 다이아몬드 버의 연삭가공 특성)

  • Lee, Keun-Sang;Lim, Young-Ho;Kwon, Dong-Ho;Choi, Man-Yong;Kim, Kyo-Han;Choi, Young-Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.66-72
    • /
    • 1997
  • This paper aims at reviewing the possibility application over normal or abnormal, detection used by AE and the wear characteristics of grinding process. In this study, when diamond bur in dentistry with chosen grinding conditions were tuned at grinding. The variation of grinding resistance and AE signal is detected by the use of AE measuring system. The tests are carried out in accordance with diamond burs and workpiece: arcyl and bovine. According to the experiment results, the following can be expected: AE has the possibility to detect the state normality and abnormality. Hpwever, the grinding resistance measuring can find it difficult to detect it. It can be accurately excepted from AE occurrence pattern in contact start point of diamond bur and bovine, grinding condition and derailment point. It is known that AErms is well compatible with grinding resistance. According to the increase of the material removal rate, the specific energy of the diamond bur is inclined to dectease and the grinding resistance has a tendency to increase.

  • PDF

Full mouth rehabilitation of deep bite patient with segmental osteotomy and orthodontic treatment (분절골절단술과 교정치료를 동반한 과개교합 환자의 완전구강회복 증례)

  • Chu, Seung-Sik;Cho, Woong-Rae;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.26-38
    • /
    • 2015
  • Teeth wear and extrusion of antagonist are commonly observed in deep bite patient having severe vertical and horizontal overlap. These problems cause collapse of occlusal plane and abnormal anterior guidance. Without restoring harmonious occlusion, loss of multiple teeth and decreased masticatory function could not be prevented. To resolve problems associated with deep bite, multidisciplinary treatment including oral surgical, orthodontic and prosthetic treatment should be performed. This clinical report describes the results of increasing occlusal vertical dimension with a full-mouth restoration procedure. The treatment procedures include extraoral and intraoral examination, diagnosis, treatment planning, diagnostic wax-up, segmental osteotomy, orthodontic intrusion and prosthodontic rehabilitation. Full mouth rehabilitation with increasing occlusal vertical dimension can solve esthetic and functional problems.

ANALYSIS OF THE CLINICAL SYMPTOMS AND THE TEMPOROMANDIBULAR JOINT DISK BY MAGNETIC RESONANCE IMAGING AFTER CONSERVATIVE TREATMENT WITH ANTERIOR REPOSITIONING SPLINT (측두하악관절 환자의 전방재위치장치 치료 전후의 임상증상 및 자기공명영상을 이용한 관절원판 변화의 분석)

  • Myoung, Shin-Won;Park, Je-Uk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.136-142
    • /
    • 2006
  • Temporomandibular joint(TMJ) disorders have characteristic clinical findings such as pain, joint sound, and abnormal jaw function. With the rapid progress in TMJ imaging techniques, magnetic resonance imaging(MRI) especially provides the clinician and researcher with the ability to evaluate TMJ disorders(effusion, anterior disk displacement) and the hard and soft tissue of the TMJ. In order to manage the internal derangement of TMJ such as anterior disk displacement, the so-called appliance therapy is commonly used. This technique became the treatment of choice before surgical intervention by many practitioners. The purpose of the present study was to evaluate and determine the efficacy of anterior repositioning splint by means of the change of the position of the disk through pre- and post-treatment MRI. MRI and clinical symptom were carefully recorded in TMJ disorder patients. The relationship between TMJ symptoms such as pain, clicking sound, and disk displacement and effusion in MRI were analyzed. Then, splint therapy was applied for 3 months according to our protocol; at day 1, patients should wear 24 hours, in order to accomodate the splint and then, wearing time is reduced to 12 hours per day for one month. During next 2 months, it is tapered to 8 hours per day according to the evaluation of the clinical symptoms. Post-treatment MRI was obtained after 3 month protocol. This treatment strategy improved the clinical symptoms of TMJ disorder, and effusion and articular disk position showed a significant change. In conclusion, a treatment modality using an anterior repositioning splint therapy is an appropriate method for temporomandibular disorder patients.

Development of Local Ground Pantograph for Power Supply to Wireless Mountain Trams (무가선 산악트램 급전을 위한 지상 집중식 급전장치 개발)

  • Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.268-275
    • /
    • 2020
  • In domestic mountain resort areas, a catenary system cannot be installed for the protection of the natural environment and view. Therefore, mountain trams must be operated wireless. In this study, a local ground pantograph, which supplies electricity to the battery on board, was developed for this purpose, and its performance was verified by tests. The system is installed on ground at stops or repair shops. While a bogie goes to the pantograph, the arms and collection shoes are raised by a spring force to make contact with the collection bar under the bogie so electric power can be supplied to the battery. Because it is a local ground type, it does not require a roof pantograph and catenary system. The system enables the mountain tram to run wireless. In addition, there is no separation and arc because it collects current while standing at stops or shops. The system has a long life because moving contact, which generates wear and damage to shoes, is avoided. The insulation resistance was above the criteria of 10 ㏁, and there was no abnormal temperature increase when a current of 335A was supplied for one hour.