• 제목/요약/키워드: Abnormal Operation

검색결과 537건 처리시간 0.032초

고속열차 주행중 이상진동에 대한 시험적 평가 (An Experimental Evaluation for an Abnormal Vibration on Running of the High Speed Train)

  • 양희주;우관제;손병구;성재호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2263-2268
    • /
    • 2011
  • THE VIBRATION MODE OF RAILWAY VEHICLE IS DIFFICULT TO FIND OUT THE CHARACTERISTICS OF MOTION DURING THE OPERATION ON THE TRACK BECAUSE THESE HAPPEN TO INDEPENDENCE OR DUPLICATION MOTION CAUSED BY VEHICLE, WHEEL/RAIL INTERACTION, TRACK IRREGULARITY AND FAILURE OF THE SUSPENSION & POWER TRANSMISSION DEVICE ETC. IT IS NAMED AN ABNORMAL VIBRATION THAT THE VIBRATION, WHICH WAS PASSED THE PRIMARY AND SECONDARY SUSPENSION, IS AFFECTED TO THE PASSENGER OR DRIVER WITHOUT DAMPING. THIS PAPER DESCRIBES AN EXPERIENCE EVALUATION TO FIND OUT THE CAUSE OF AN ABNORMAL VIBRATION WHICH WAS HAPPEN AT THE CAB OF POWER CAR IN KTX-SANCHEON TRAINSET WHEN ON RUNNING AT HIGH SPEED ZONE.

  • PDF

A Study on Feasibility Evaluation for Prognosis Systems based on an Empirical Model in Nuclear Power Plants

  • Lee, Soo Ill
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.26-32
    • /
    • 2012
  • This paper introduces a feasibility evaluation method for prognosis systems based on an empirical model in nuclear power plants. By exploiting the dynamical signature characterized by abnormal phenomena, the prognosis technique can be applied to detect the plant abnormal states prior to an unexpected plant trip. Early $operator^{\circ}{\emptyset}s$ awareness can extend available time for operation action; therefore, unexpected plant trip and time-consuming maintenance can be reduced. For the practical application in nuclear power plant, it is important not only to enhance the advantages of prognosis systems, but also to quantify the negative impact in prognosis, e.g., uncertainty. In order to apply these prognosis systems to real nuclear power plants, it is necessary to conduct a feasibility evaluation; the evaluation consists of 4 steps (: the development of an evaluation method, the development of selection criteria for the abnormal state, acquisition and signal processing, and an evaluation experiment). In this paper, we introduce the feasibility evaluation method and propose further study points for applying prognosis systems from KHNP's experiences in testing some prognosis technologies available in the market.

상용 차량의 주행 중 발생하는 캡의 진동에 관한 연구 (A study of commercial vehicle cab vibration on the driving conditions)

  • 최병재;한인규;조정욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.472-475
    • /
    • 2014
  • Abnormal cab vibrations in the Y direction in commercial vehicles during driving(70~90kph) are not common vibrations that happen to vehicles during driving and can be an obstacle to normal driving. This study conducted Operation Deflection Shape(ODS) testing to identify the causes of those abnormal cab vibrations and find solutions for them and also a sine sweep test to find resonance and frequency in the cab suspension system and set directions for improvement. The study also altered the shape of the bush inner part for changes to the rigidity features of the cab bush in the Y direction and revised the design with optimal rigidity in the Y direction, thus improving abnormal cab vibrations in the Y direction during driving.

  • PDF

이상조건하에서 가정용 연료전지 시스템의 성능 및 안전성 평가에 관한 연구 (A Study on the Performance and Safety Evaluation for Residential Fuel Cell System under the Abnormal Condition)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.10-13
    • /
    • 2008
  • Fuel cell systems have witnessed remarkable development in recent years as they offer a clean and efficient alternative for power generation. Testing was conducted to determine the safety performance of a residential fuel cell system when subjected to abnormal operation condition, especially for voltage sag and fuel cut. In case of voltage sag to 198V, its arriving time at rated power had shown a slight lag but there wasn't any noticeable change when operating it between rated voltage(220V) and 10% voltage sag(198V). In case of fuel cut, it also showed stable shut-down characteristics. The test results are being used to develop a new safety evaluation for residential fuel cell system.

  • PDF

Design and evaluation of artificial intelligence models for abnormal data detection and prediction

  • Hae-Jong Joo;Ho-Bin Song
    • Journal of Platform Technology
    • /
    • 제11권6호
    • /
    • pp.3-12
    • /
    • 2023
  • In today's system operation, it is difficult to detect failures and take immediate action in the case of a shortage of manpower compared to the number of equipment or failures in vulnerable time zones, which can lead to delays in failure recovery. In addition, various algorithms exist to detect abnormal symptom data, and it is important to select an appropriate algorithm for each problem. In this paper, an ensemble-based isolation forest model was used to efficiently detect multivariate point anomalies that deviated from the mean distribution in the data set generated to predict system failure and minimize service interruption. And since significant changes in memory space usage are observed together with changes in CPU usage, the problem is solved by using LSTM-Auto Encoder for a collective anomaly in which another feature exhibits an abnormal pattern according to a change in one by comparing two or more features. did In addition, evaluation indicators are set for the performance evaluation of the model presented in this study, and then AI model evaluation is performed.

  • PDF

개인별 이상신호 검출과 QRS 패턴 변화에 따른 조기심실수축 분류 (PVC Classification by Personalized Abnormal Signal Detection and QRS Pattern Variability)

  • 조익성;윤정오;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제18권7호
    • /
    • pp.1531-1539
    • /
    • 2014
  • 조기심실수축(PVC)은 가장 보편적인 부정맥으로 심실세동, 심실빈맥 등과 같은 위험한 상황을 유발할 수 있는 가능성을 가지고 있기 때문에 이의 조기 검출은 매우 중요하다. 하지만 ECG 신호의 개인 차이가 있음에도 불구하고, 일반적인 신호의 판단 규칙에 따라 진단을 수행함으로써 성능하락이 나타날 수 밖에 없다. 이러한 문제점을 극복하기 위해서는 개인에 따른 이상 신호를 검출한 후 다양한 QRS 패턴을 고려하여 PVC를 분류할 수 있는 알고리즘이 필요하다. 본 연구에서는 개인별 이상신호 검출과 QRS 패턴 변화에 따른 PVC 분류 기법을 제안한다. 이를 위해 전 처리 과정과 차감기법을 통해 R파를 검출하였으며, 개인별 이상신호를 검출하였다. 이후 QRS 패턴에 따른 QS 간격과 R파의 진폭 변화율에 따라 PVC를 분류하였다. 제안한 알고리즘의 이상 신호 검출 및 PVC 분류 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, 이상 신호 검출률은 98.33%, PVC는 각각 94.46%의 평균 분류율을 나타내었다.

자동열차운전장치를 이용한 도시철도 신호설비의 개량방안에 관한 연구 (A Study on Improvement Method of the Subway Signalling System Using Automatic Train Operation Device)

  • 강성구;최승호;조봉관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.145-150
    • /
    • 2003
  • The national subway went under construction in 1971, and after three years of endeavor, Seoul subway line number one opened for traffic in 1974. Line number two went under construction in 1978 and it opened for traffic in 1984. With the use of safety operation for more than 20 years, the life cycle nearly came to an end. Therefore the improvements for the safety operation are unavoidable. The total system should not be affected when the new and conventional systems are overlapped, the system operation is in the initial stage, and it confronts the situation of abnormal operation. However, there is a total lack of experience in construction and improvement for the trains that are in the use of large transport and density headway. In this paper, we propose an improvement method of the subway signalling system using ATO (Automatic Train Operation control scheme) to which the latest Digital ATC is applied, and examine the first application model of ATO system.

  • PDF

기흉을 합병한 폐림프관평활근종증 치험 1례 (Pulmonary Lymphangioleiomyomatosis with Pneumothorax)

  • 장인성;이준복;고정관;양성린;김용훈;이철세
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1057-1059
    • /
    • 1999
  • Lymphangioleiomyomatosis(LAM) is defined as an abnormal proliferation of smooth muscles in the lung tissue throughout lymphatics, vascular and bronchial structure. A 52-year-old postmenopausal woman was admitted to our hospital for recurrent pneumothorax. She was treated for medroxyprogesterone by LAM 1 month ago. We performed operation of pulmonary partial resection and pleurodesis. The patient is receiving continuous medroxyprogesterone and Leuplin administration, and currently, 6 months after the operation, is still showing good results.

  • PDF

폐격리증 2례 보고 및 대한 흉부외과학회지에 발표된 19례의 문헌 고찰 (Bronchopulmonary Sequestration - Report of 2 cases and review of 19 cases published in the Korean Journal of Thoracic and Cardiovascular Surgery -)

  • 곽영태
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.829-838
    • /
    • 1987
  • Bronchopulmonary sequestration is a rare congenital malformation of the lung, concerning about the abnormal feeding systemic artery, may happen a serious complication of heeding during operation if not recognized before operation. High index of suspicion of sequestration is the key to successful operative procedure with the aid of characteristic recurrent and long-standing symptoms, its location, and invasive or non-invasive diagnostic tools. We report 2 cases of intralobar type of bronchopulmonary sequestration and review 10 articles about the subject, totaling of 21 cases.

  • PDF

선재 가이드롤러 모니터링 시스템 개발 (The Development of Monitoring System for Guide Roller in Wire Rolling Process)

  • 손붕호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.671-673
    • /
    • 1999
  • In order to cope with the occurrence of abnormal operation, rotatory condition monitoring system for guide roller of finishing train in wire rolling has been developed. In this study, proximity sensor and its holding devices that could overcome severe in-situ measurement conditions was designed and MMI software using C++ was programmed. Performance of the developed system turned out to be good enough as results of in-line test for POSCO #3 wire rolling mill. It is expected to contribute to prevent the cobble and the grade-down of products caused by the abnornormal operation of guide rollers.

  • PDF