• 제목/요약/키워드: Abnormal Gait

검색결과 89건 처리시간 0.023초

정상인에서 쭈그림보행 시뮬레이션 시 관찰된 보상적 전략 (Compensatory Strategy Observed in the Simulated Crouch Gait of Healthy Adults)

  • 김택훈;권오윤;이충휘;조상현;권혁철;김영호
    • 한국전문물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.53-67
    • /
    • 2004
  • This simulation study investigated the characteristics of normal gait, $30^{\circ}$ crouch gait, $30^{\circ}$ crouch/equinus gait, $45^{\circ}$ crouch gait, $45^{\circ}$ crouch/equinus gait. The knee flexion angles were restricted using a specially designed orthosis. This study was carried out in a motion analysis laboratory of the National Rehabilitation Center. Fifteen healthy male subjects were recruited for the study. The purposes of this study were (1) to compare spatiotemporal parameters, kinematics, and kinetic variables in the sagittal plane among the different gait, (2) to investigate the secondary compensatory strategy, and (3) to suggest biomechanical physical therapy treatment methods. The pattern and magnitude observed in each condition were similar to those of normal gait, except the peak knee extension moment of the unrestricted ankle motion-crouch gait. However, the speed of the $45^{\circ}$ crouch gait was half that of a normal gait. The ankle joint moment in the crouch/equinus gait showed the double-bump pattern commonly observed in children with spastic cerebral palsy, and there was no significant difference in gait speed as compared with normal gait. The peak ankle plantar-flexor moment and ankle power generated during the terminal stance in the crouch/equinus conditions were reduced as compared with normal and $45^{\circ}$ crouch gaits (p<.05). The crouch/equinus gait at the ankle joint was an effective compensatory mechanism. Since ankle plantarflexion contracture can be exacerbated secondary to the ankle compensatory strategy in the crouch/equinus gait, it is necessary to increase the range of ankle dorsiflexion and the strength of plantarflexion simultaneously to decrease the abnormal biomechanical advantages of the ankle joint.

  • PDF

재활환자 모의보행 패턴분석을 이용한 하지 편측 장애자의 정량적 재활상태 모니터링 (Quantitative Rehabilitation Extent Monitoring for Unilateral Lower Extremity Disabled Patients using Simulated Gait Pattern Analysis)

  • 문동준;김주영;노시철;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.227-233
    • /
    • 2014
  • In this paper, to quantitatively evaluate the degree of rehabilitation for the disabled of unilateral lower extremity, we compared the EMG pattern of normal and simulated abnormal gait. The EMG signal was measured at a rate of 1 kHz on the quadriceps and biceps femoris, the pressure sensor was attached to the sole in order to distinguish the gait cycle. Integrated EMG (IEMG) was obtained by the gait cycle, and classified four patterns that were the normal gait pattern, amplitude decrease pattern, reversed pattern, and irregular pattern. For comparison of the patterns, a curve fitting was performed using the trigonometric functions. The result of curve fitting, the method using a variable A that corresponds to the amplitude of the regression curve was able to distinguish the reverse pattern and remaining pattern. The coefficient of determination ($R^2$) representing coincidence of the pattern of the regression curve and EMG was confirmed the biggest value at the normal gait. Therefore, the degree of normal gait can be confirmed using the coefficient of determination. This results show that it is possible to quantitatively confirm the degree of unilateral lower extremity disabled rehabilitation, and it will be contributed to the study of efficient rehabilitation methods by objective analysis.

보행수 측정 및 보행패턴 분류 알고리즘 (A Study on a Algorithm of Gait Analysis and Step Count with Pressure Sensors)

  • 도주표;최대영;김동준;김경호
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1810-1814
    • /
    • 2017
  • This paper develops an approach to the algorithm of Gait pattern Analysis and step measurement with Multi-Pressure Sensors. The process of gait consists of 8 steps including stance and swing phase. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. normal gait proceed from heel, forefoot and big toe over time. While normal gait proceeds, values of heel, forefoot and big toe can be changed over time. So Each values of pressure sensors over time could discriminate whether it is normal or abnormal gait. Measuring Device consists of non-inverting amplifiers and low pass filter. Through timetable of values, normal gait pattern can be analyzed, because of supported weight of foot. Also, the peak value of pressure can judge whether it is walking or running. While people are running, insole of shoes is floating in the air on moment. Using this algorithm, gait analysis and step count can be measured.

The Effect of Ankle Balance Taping on Gait and Balance in Stroke Patients

  • Kyoung-Won Kim;Ki Bum Jung;Dong-Ho Kim;Yongwoo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.123-129
    • /
    • 2023
  • Objective: Kinesio tape has been applied to the ankle to improve balance and gait. Stroke patients show abnormal gait patterns due to foot drop. This study aimed to determine the effects of ankle balance taping which to support the ankle joint on balance and gait in patients with chronic stroke. Design: A randomized controlled trial. Methods: Twenty-four chronic stroke patients were selected and randomized into experimental group (n=12) and control group (n=12). The experimental group applied kinesio taping three times a week for three weeks, and the control group applied placebo taping for the same amount of time. To evaluate the effectiveness of the treatment, the subjects' walking ability, static balance, and dynamic balance were assessed before and after the experiment. Gait speed and spatiotemporal gait ability were measured to examine walking ability, postural sway velocity and velocity moment for static balance, and Timed-Up and Go test and Berg Balance Scale were conducted to check dynamic balance. Results: The experimental group showed a significant increase in walking ability, static balance, and dynamic balance in the within-group pre-post difference (p<0.05). In the between-group comparison, the experimental group had a significant difference in walking ability than the control group (p<0.05). Conclusions: Ankle balance taping can help improve gait, and this study can be used as a basis for future studies of ankle balance taping.

전방십자인대 재건수술 환자와 정상인의 보행 연구 (Gait Study on the Normal and ACL Deficient Patients After Ligament Reconstruction Surgery Using Chaos Analysis Method)

  • 고재훈;문병영;서정탁;손권
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.435-441
    • /
    • 2006
  • The anterior cruciate ligament(ACL) is an important stabilizer of knee joint. The ACL injury of knee is common and a serious ACL injury leads to ligament reconstruction surgery. Gait analysis is essential to identify knee condition of patients who display abnormal gait. The purpose of this study is to evaluate and classify knee condition of ACL deficient patients using a nonlinear dynamic method. The nonlinear method focuses on understanding how variations in the gait pattern change over time. The experiments were carried out for 17 subjects(l2 healthy subjects and five subjects with unilateral deficiency) walking on a motorized treadmill for 100 seconds. Three dimensional kinematics of the lower extremity were collected by using four cameras and KWON 3D motion analysis system. The largest Lyapunov exponent calculated from knee joint flexion-extension time series was used to quantify knee stability. The results revealed the difference between healthy subjects and patients. The deficient knee was significantly unstable compared with the contralateral knee. This study suggests an evaluation scheme of the severity of injury and the level of recovery. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

The Effect of Shoe Heel Types and Gait Speeds on Knee Joint Angle in Healthy Young Women - A Preliminary Study

  • Chhoeum, Vantha;Wang, Changwon;Jang, Seungwan;Min, Se Dong;Kim, Young;Choi, Min-Hyung
    • 인터넷정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.41-50
    • /
    • 2020
  • The consequences of wearing high heels can be different according to the heel height, gait speed, shoe design, heel base area, and shoe size. This study aimed to focus on the knee extension and flexion range of motion (ROM) during gait, which were challenged by wearing five different shoe heel types and two different self-selected gait speeds (comfortable and fast) as experimental conditions. Measurement standards of knee extension and flexion ROM were individually calibrated at the time of heel strike, mid-stance, toe-off, and stance phase based on the 2-minute video recordings of each gait condition. Seven healthy young women (20.7 ± 0.8 years) participated and they were asked to walk on a treadmill wearing the five given shoes at a self-selected comfortable speed (average of 2.4 ± 0.3 km/h) and a fast speed (average of 5.1 ± 0.2 km/h) in a random order. All of the shoes were in size 23.5 cm. Three of the given shoes were 9.0 cm in height, the other two were flat shoes and sneakers. A motion capture software (Kinovea 0.8.27) was used to measure the kinematic data; changes in the knee angles during each gait. During fast speed gait, the knee extension angles at heel strike and mid-stance were significantly decreased in all of the 3 high heels (p<0.05). The results revealed that fast gait speed causes knee flexion angle to significantly increase at toe-off in all five types of shoes. However, there was a significant difference in both the knee flexion and extension angles when the gait in stiletto heels and flat shoes were compared in fast gait condition (p<0.05). This showed that walking fast in high heels leads to abnormal knee ROM and thus can cause damages to the knee joints. The findings in this preliminary study can be a basis for future studies on the kinematic changes in the lower extremity during gait and for the analysis of causes and preventive methods for musculoskeletal injuries related to wearing high heels.

기능기반 형상변형기술을 응용한 환자맞춤형 근골격 모델의 보행패턴 예측에 관한 연구 (Musculoskeletal Models to Predict Patient-specific Gait Patterns Using Function-based Morphing Technique)

  • 박병건;구본열;박은주;체재욱;이순혁;김재정
    • 한국CDE학회논문집
    • /
    • 제17권6호
    • /
    • pp.443-455
    • /
    • 2012
  • The configuration of a musculoskeletal (MS) system is closely related to the individual motions of the human body. Many researches have been focused on evaluating the associations between the MS configuration and the individual motion using patient-specific MS models, but it still remains a challenging issue to accurately predict the motion by differed configurations of the MS system. The main objective of this paper is to predict the changes of a patient-specific gait by altering the geometric parameters of the hip joint using function-based morphing method (FBM). FBM is suitable for motion analysis since this method provide a robust way to morph a MS model while preserving the biomechanical functions of the bones. Computed-muscle control technique is used to calculate the muscle excitations to reproduce the targeted motion within a digital MS model without the motion-captured data. We applied this approach to a patient who has an abnormal gait pattern. Results showed that the femoral neck length and the angle significantly affect to the motion especially for the hip abduction angle during gait, and that this approach is suitable for gait prediction.

시각적 피드백과 리듬청각자극을 통한 트레드밀 보행훈련이 뇌졸중 환자의 보행능력에 미치는 영향 (Effects of Visual Feedback and Rhythmic Auditory Stimulation on Walking of Stroke Patients Induced by Treadmill Walking Training)

  • 박진;김범룡;김태호
    • 한국전문물리치료학회지
    • /
    • 제25권2호
    • /
    • pp.53-61
    • /
    • 2018
  • Background: Stroke patients show abnormal walking patterns due to brain injury. In order to have the desired walking pattern, appropriate stimulation is required to activate the central pattern generator. For this reason, our study performed treadmill ambulatory training with rhythmic auditory stimulation. However we did not consider the influence of visual feedback. Objects: The purpose of this study was to compare the gait abilities in chronic stroke patients following either treadmill walking training with rhythmic auditory stimulation and visual feedback (TRASVF) or treadmill walking training with rhythmic auditory stimulation (TRAS) alone. Methods: Twenty-one stroke patients were divided into two groups: A TRASVF group (10 subjects) and a TRAS group (11 subjects). They received 30 minutes of neuro-developmental therapy (NDT) and walking training for 30 minutes, five times a week for three weeks. Temporal and spatial gait parameters were measured before and after the training period. The Biodex gait trainer treadmill system measured gait parameters. Results: After the training periods, the TRASVF group showed a significant improvement in walking speed, the step length of the affected limb, and time on each foot of the affected limb when compared to the TRAS group (p<.05). Conclusion: The results of this study showed that the treadmill walking training with rhythmic auditory stimulation and visual feedback improved individual gait ability more than the treadmill walking training with rhythmic auditory stimulation alone. Therefore, visual feedback should be considered along with rhythmic auditory stimulation training.

편측성 걸음걸이 트레드밀 훈련이 만성 뇌졸중 환자의 보행 속도와 대칭성 회복에 미치는 효과 (Effects of Unilateral Step Treadmill Training on the Gait Speed and Recovery of Gait Symmetry in Patients with Chronic Stroke)

  • 이지연;천승철
    • 대한통합의학회지
    • /
    • 제10권4호
    • /
    • pp.145-151
    • /
    • 2022
  • Purpose : Stroke patients exhibit abnormal walking patterns such as slow walking speed and asymmetrical walking values. The recovery of symmetrical walking in the stance phase using a treadmill means improvements in walking speed and asymmetrical walking. The purpose of this research was to investigate the effect of unilateral step treadmill training (USTT) on gait speed and the recovery of symmetrical walking in chronic stroke patients. Methods : Fifteen patients (11 men and 4 women) with chronic stroke participated in this study. The 10-meter walk test (10MWT) and GAITRite system were used to determine the intervention-related changes in gait speed and symmetrical walking values such as non-paretic step length (NSL), non-paretic step time (NST), paretic single-support time (PSST), step length asymmetry (SLA), and step time asymmetry (STA) after USTT. All participants completed USTT and underwent measurements at 3 different times: at pretest, posttest, and the follow-up test. Repeated-measures analysis of variance was used to compare walking speed and asymmetrical walking values. The statistical significance level was set at p<.05. Results : Walking speed by 10MWT (p<.05) showed significant improvements after USTT as follows: at pretest and posttest (p<.05), posttest and follow-up test (p<.05), and pretest and follow-up test (p<.05). Recovery of symmetrical walking patterns such as NSL (p<.05), NST (p<.05), and SLA (p<.05) were observed after USTT. However, no significant improvements were found in PSST (p>.05) and STA (p>.05) in symmetrical gait. Conclusion : This study suggests that USTT may have a positive effect on walking speed and symmetrical walking patterns in chronic stroke patients. Thus, this study contributes to the existing knowledge about the usefulness of USTT for the effective management of patients with chronic stroke. Further studies are needed to generalize these findings.

3축 가속도 센서를 이용한 보행 불균형 평가 시스템에 관한 연구 (A Study on Gait Imbalance Estimation System using 3-axis Accelerometer)

  • 최항적;박용덕;심현민;이상민
    • 재활복지공학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-43
    • /
    • 2015
  • 본 논문에서는 3축 가속도 센서를 이용하여 보행 불균형을 진단하는 효율적 시스템을 제안한다. 제안된 하드웨어 시스템은 주로 보행시 발목 세 방향의 가속도를 무선으로 측정할 수 있는 3축 가속도 센서와 데이터 전송을 위한 임베디드 시스템으로 구성되어 있다. 획득된 데이터를 정규화 처리한 후, ROCC (ratio of correlation coefficient)를 이용하여 정상적인 보행의 대칭성과 비정상적인 보행의 대칭성을 비교 분석하였다. 건강한 성인 10명을 대상으로 실험을 실시하였고 개인당 총 5회 반복 실험을 하였다. 비정상 보행을 만들기 위해 한쪽 발의 굽의 높이를 변화시켰다. 결과를 보면 보행 불균형이 커질수록 ROCC의 값이 점차 기준에서 멀어지는 것을 알 수 있었으며 제안된 시스템이 보행 불균형 평가에 사용가능한 것이 확인되었다.

  • PDF