• Title/Summary/Keyword: Ablation Techniques

Search Result 68, Processing Time 0.026 seconds

A SE Approach to Designing and Developing of Motion Control for Radioactive Waste Decontamination

  • Ngbede, Utah Michael;Olaide, Oluwasegun Adebena;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.11-20
    • /
    • 2021
  • Decontamination of systems, structures and components (SSC) during the decommissioning of a Nuclear Power Plant (NPP) can be for a variety of reasons. The main reasons for decontamination are: to reduce the contamination of SSC to a reasonably low level, to reduce the potential for the spread of contaminants into the environment and to reduce the cost of disposal due to the reduced level of contamination in a particular SSC. The decontamination technique can be aggressive or non-aggressive depending on the intent after the decontamination process. Aggressive decontamination technique is used when the intent is not to reuse the SSC while a non-aggressive decontamination technique is used with the intent of SSC reuse. For different SSCs there are different decontamination techniques that can be used, each having its own advantages and drawbacks. Metal components such as pipes in the nuclear power plant account for a large amount of nuclear wastes generated. Some of these wastes can be reused if the contaminant level is reduced to an acceptable level. Laser ablation is a non-aggressive decontamination technique that can be used to reduce the contamination in pipes to an acceptable level with no secondary waste generated during the process. The operation and control of a laser ablation device must be precise to achieve a high decontamination factor. This precision can be achieved by a well-designed motion control system. For this purpose, a motion control system was developed consisting of two parts: the first part being the precise control of the laser ablation device inside the pipe and the second part is the control of the laser ablation device outside the pipe. This paper describes the Systems Engineering approach for the development process of a motion control system for the Laser decontamination system.

Clinical Approach for Thyroid Radiofrequency Ablation (갑상선 고주파 절제술을 위한 임상진료)

  • Jung Suk Sim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1017-1030
    • /
    • 2023
  • Radiofrequency ablation (RFA) is a non-surgical treatment for symptomatic, benign thyroid nodules. This treatment works by heating and destroying the nodule tissue, which results in reduction of its size and alleviation of the symptoms involved. RFA is indicated for nodules which are confirmed to be benign on two or more cytological or histological examinations, and which result in clinical symptoms requiring medical treatment. It is associated with good short-term outcomes on one-year follow-up; however, 20%-30% of the nodules regrow after more than three years. Therefore, on the basis of long-term follow-up, management of regrowth is key to patient care following RFA. Regrowth is more likely to occur in nodules that are large in size prior to RFA, and in those with high or increased vascularity. Recently, new techniques such as hydrodissection, artery-first ablation, and venous ablation have been introduced to inhibit regrowth. In addition, appropriate criteria for additional RFA should be applied to manage regrowth and prolong its therapeutic effects. RFA is essentially an alternative to surgery; therefore, the ultimate goal of this procedure is to avoid surgery permanently, rather than to achieve temporary effects.

Comparison of the efficacy of genicular nerve phenol neurolysis and radiofrequency ablation for pain management in patients with knee osteoarthritis

  • Gokhan Yildiz;Gevher Rabia Genc Perdecioglu;Damla Yuruk;Ezgi Can;Omer Taylan Akkaya
    • The Korean Journal of Pain
    • /
    • v.36 no.4
    • /
    • pp.450-457
    • /
    • 2023
  • Background: Genicular nerve neurolysis with phenol and radiofrequency ablation (RFA) are two interventional techniques for treating chronic refractory knee osteoarthritis (KOA) pain. This study aimed to compare the efficacy and adverse effects of both techniques. Methods: Sixty-four patients responding to diagnostic blockade of the superior medial, superior lateral, and inferior medial genicular nerve under ultrasound guidance were randomly divided into two groups: Group P (2 mL phenol for each genicular nerve) and Group R (RFA 80℃ for 60 seconds for each genicular nerve). The numeric rating scale (NRS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were used to evaluate the effectiveness of the interventions. Results: RFA and phenol neurolysis of the genicular nerves provided effective analgesia within groups at 1 week, 1 month, and 3 months compared to baseline. There was no significant difference between the groups in terms of NRS and WOMAC scores at all measurement times. At the 3rd month follow-up, 50% or more pain relief was observed in 53.1% of patients in Group P and 50% of patients in Group R. The rate of transient paresthesia was 34.4% in Group P and 6.3% in Group R, and this was significantly higher in Group P. Conclusions: Neurolysis of the genicular nerves with both RFA and phenol is effective in the management of KOA pain. Phenol may be a good alternative to RFA. Further studies are needed on issues such as dose adjustment to prevent transient paresthesia response.

Development of Bio-ballistic Device for Laser Ablation-induced Drug Delivery

  • Choi, Ji-Hee;Gojani, Ardian B.;Lee, Hyun-Hee;Jeung, In-Seuk;Yoh, Jack J.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.68-71
    • /
    • 2008
  • Transdermal and topical drug delivery with minimal tissue damage has been an area of vigorous research for a number of years. Our research team has initiated the development of an effective method for delivering drug particles across the skin (transdermal) for systemic circulation, and to localized (topical) areas. The device consists of a micro particle acceleration system based on laser ablation that can be integrated with endoscopic surgical techniques. A layer of micro particles is deposited on the surface of a thin metal foil. The rear side of the foil is irradiated with a laser beam, which generates a shockwave that travels through the foil. When the shockwave reaches the end of the foil, it is reflected as an expansion wave and causes instantaneous deformation of the foil in the opposite direction. Due to this sudden deformation, the microparticles are ejected from the foil at very high speeds, and therefore have sufficient momentum to penetrate soft body tissues. We have demonstrated this by successfully delivering cobalt particles $3\;{\mu}m$ in diameter into gelatin models that represent soft tissue with remarkable penetration depth.

A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System

  • Rhie, Jong Won;Shim, Jeong Su;Choi, Won Seok
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • Background The erbium:yttrium scandium gallium garnet (Er:YSGG) laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide ($CO_2$) laser and the erbium-doped yttrium aluminum garnet (Er:YAG) laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser. Methods Twenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera) twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured. Results Study subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment. Conclusions The 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

Thermal Flow Characteristics Driven by Arc Plasmas in a Thermal Puffer Type GCB (열파퍼식 가스차단기에서 발생하는 아크 플라즈마에 의한 열유동 특성)

  • Lee, Jong-Chul;Kim, Youn J.
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.527-532
    • /
    • 2005
  • During the last ten years the new interruption techniques, which use the arc energy itself to increase the pressure inside a chamber by the PTFE nozzle ablation, have displaced the puffer circuit breakers due to reduced driving forces and better maintainability. In this paper, we have investigated the thermal flow characteristics inside a thermal puffer type gas circuit breaker by solving the Wavier-Stokes equations coupled with Maxwell's equations for considering all instabilities effects such as turbulence and Lorentz forces by transient arc plasmas. These relative inexpensive computer simulations might help the engineer research and design the new interrupter in order to downscale and uprating the GIS integral.

Treatment of glabellar frown lines using selective nerve block with radiofrequency ablation (고주파절제술을 통한 선택적 신경차단법을 이용한 미간주름의 개선)

  • Hwang, Yong Seok;Kim, Young Seok;Roh, Tai Suk;Tark, Kwan Chul;Lee, Kun Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.205-210
    • /
    • 2009
  • Purpose: Corrugator supercilii muscle pulls eyebrow to inferomedial direction and produces the vertical component of the glabellar line formation. Current techniques for eliminating of glabellar frown include direct resection of corrugators and botulinum toxin injection. Muscle resection in endoscopic face lift procedure is relatively complex and has many disadvantages ranging from possible nerve injury, postoperative edema, pain and a long recovery period. The Botox treatment on the other hand is much more simple in technique but has a short duration of action. The authors have attempted new ways of finding improved treatment of the glabellar frown by selectively blocking of motor nerves innervating the corrugator supercili muscle by using radiofrequency ablation technique. Methods: A total of 80 patients were recruited in our study during the period between Feb. 2007 to June 2008. A probe was introduced from the supraorbital ridge and advanced to the corrugator supercilii muscle. Nerve stimulator was then used to locate the nerve innervating the corrugator and radiofrequency ablation of the nerve was done. Results: In all patients, there were marked improvement in glabellar frown after treatment. There were no reported cases of any relapses during the follow up period. No complication was noted such as facial nerve injury. No patient complained of any adverse symptoms other than slight discomfort due to swelling of the operation site. Conclusion: The treatment of glabellar frown lines using selective nerve block with radiofrequency ablation was not only less invasive but also excellent in surgical outcomes.

Analytical Techniques Using ICP-MS for Clinical and Biological Analysis

  • Ko, Jungaa;Lim, H. B.
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.85-90
    • /
    • 2015
  • This article reviews recent analytical techniques using inductively coupled plasma-mass spectrometry (ICP-MS) immunoassay for clinical and bio analysis. We classified the techniques into two categories, direct and indirect analysis, which depend upon a guideline of whether tagging materials are used or not. Direct analysis is well known, and generally used in conjunction with various other techniques, such as laser ablation, chromatographic separations, etc. Recently, indirect analysis using tagging elements has intensively been discussed because of its importance in future applications to bio and clinical analysis, including environmental and food industries. The method has shown advantages of multiplex detection, excellent sensitivity, and short analysis time owing to signal amplification and magnetic separation. Now, it expands the application field from small biomolecules to large cells.

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.

Objective Evaluation of Recurrent Neural Network Based Techniques for Trajectory Prediction of Flight Vehicles (비행체의 궤적 예측을 위한 순환 신경망 기반 기법들의 정량적 비교 평가에 관한 연구)

  • Lee, Chang Jin;Park, In Hee;Jung, Chanho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.540-543
    • /
    • 2021
  • In this paper, we present an experimental comparative study of recurrent neural network based techniques for trajectory prediction of flight vehicles. We defined and investigated various relationships between input and output under the same experimental setup. In particular, we proposed a relationship based on the relative positions of flight vehicles. Furthermore, we conducted an ablation study on the network architectures and hyperparameters. We believe that this comprehensive comparative study serves as a reference point and guide for developers in choosing an appropriate recurrent neural network based techniques for building (flight) vehicle trajectory prediction systems.