• 제목/요약/키워드: Ablation Characteristics

검색결과 135건 처리시간 0.027초

레이저 어블레이션 기반 가공 및 계측에서 공정변수의 영향 (Effects of Process Parameters on Laser Ablation Based Machining and Measurements)

  • 정성호;이석희
    • 한국정밀공학회지
    • /
    • 제28권12호
    • /
    • pp.1359-1365
    • /
    • 2011
  • The changes of ablation characteristics with respect to laser parameters and material parameters during pulsed laser ablation of solids were discussed with experimental results. Although laser wavelength, laser pulse width, and laser pulse energy are the primary factors to be considered, it is shown that other parameters such as laser spot size and material properties also critically influence on the ablation results. It is further demonstrated that the microstructural characteristics of the target can lead to completely different ablation rate and surface morphology.

레이져를 이용한 3차원 형상가공에 관한 연구 (Laser application in 3-D micromachining)

  • 윤경구;이성국;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.75-78
    • /
    • 1995
  • This paper presents the feasibility of laser ablation process in 3-D micro machining of MEMS (micro Electro Mechanical System)parts. The micro machining characteristics of polymer(Energy fluence, pulse repetition rate, number of pulse, ablation rate)are investigated and 3-D micro machined samples are demonstrated.

  • PDF

노즐용삭을 고려한 SF6 가스차단기 노즐의 열적회복특성 해석 (Analysis of Thermal Recovery Characteristics for Nozzle of SF6 GCB Considering Nozzle Ablation)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.76-82
    • /
    • 2005
  • In this paper, a method for analyzing the thermal recovery characteristics of the nozzle of gas circuit breaker was described. In order to obtain thermal recovery characteristics, the transient simulation of SF6 arc plasma within the nozzle was carried out. In particular, the nozzle ablation was taken into account by simultaneously solving the PTFE concentration equation with the governing equations such as continuity, momentum and energy equation. After that, post arc current calculation was performed with the rate of rise of recovery voltage changed. From the calculated post arc current, it was possible to suggest the thermal recovery characteristics of the nozzle of gas circuit breaker.

피코초 레이저를 이용한 Eagle Glass 절단 시 가공성 평가 (Processing Evaluations of the Eagle Glass Cutting Using Pico-second Laser)

  • 이상균;이영곤;김재도
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.403-408
    • /
    • 2013
  • In this paper, the characteristics of ablation processing of the eagle glass by pico-second laser are investigated. The laser ablation is used to process micro forms on materials. The ablation causes little thermal effect and little burr on the surface of eagle glass. In order to examine the characteristics of panic cracks, experiments are conducted under various cutting conditions such as a frequency of 600 kHz, laser powers, scan speeds and number of scan(NS). To minimize the panic cracks, the specimens are heated at $30^{\circ}C$, $45^{\circ}C$, and $60^{\circ}C$ for ten minutes respectively and then they are broken by hands. Laser powers, NS and scan speeds have an effect on glass cutting results. The ablation depths increase with an increase in the laser power and NS whereas the panic cracks decrease with an increase in scan speed. The high temperature on processed specimens reduces the panic cracks and makes good results of laser cutting. The optimal condition for eagle glass laser cutting is found to be at 30 W of laser power, 3 mm/s of scan speed and 500 of NS, respectively.

순수 알루미나와 탄소나노튜브 강화 알루미나 복합체의 극초단 펄스레이저 가공특성 비교 (Comparison of Ablation Characteristics of Carbon Nanotube reinforced Hybrid Al2O3 by using Ultrashort Pulse Laser)

  • 이준영;윤지욱;강명창;조성학
    • 한국기계가공학회지
    • /
    • 제12권6호
    • /
    • pp.23-29
    • /
    • 2013
  • In this paper, pure $I_{ph}$ and hybrid carbon nanotube reinforced $I_{ph}$ were sintered using the SPS(spark plasma sintering) method for high densification. A nanosecond laser (${\lambda}=1063nm$, ${\tau}P=10ns$) and a femtosecond laser (${\lambda}=1027nm$, ${\tau}P=380fs$) were installed on an optical system for the micromachining test. The ablation characteristics of the pure $I_{ph}$ and CNT/$I_{ph}$ composites, such as thermal effect and ablation depth, were investigated using FE-SEM and a confocal microscope device. Laser machining results for the two mating materials showed improved performances: CNT/$I_{ph}$ composites showed good surface morphology of hole drilling without a melting zone due to the composites' high thermal properties; also, the ablated depth of CNT/$I_{ph}$ was higher than that of pure $I_{ph}$.

Radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia in children and adolescents: a single center experience

  • Hyun, Myung Chul
    • Clinical and Experimental Pediatrics
    • /
    • 제60권12호
    • /
    • pp.390-394
    • /
    • 2017
  • Purpose: Atrioventricular nodal reentry tachycardia (AVNRT) is less common in pediatric patients than in adult patients. Thus, data for pediatric AVNRT patients are insufficient. Hence, we aimed to analyze the patient characteristics, treatment, and any recurrences in pediatric AVNRT patients. Methods: We reviewed the records of 50 pediatric AVNRT patients who had undergone radiofrequency catheter ablation (RFCA) between January 1998 and December 2016 at a single regional center. The patients were aged ${\leq}18years$. Results: Among 190 pediatric patients who underwent RFCA for tachyarrhythmia, 50 (26.3%; mean age, $13.4{\pm}2.6years$) were diagnosed as having AVNRT by electrophysiological study. Twenty-five patients (25 of 50, 50%) were male. Twenty patients (20 of 50, 40%) used beta-blockers before RFCA. All patients had no structural heart disease except 1 patient with valvular aortic stenosis and coarctation of the aorta. RFCA was performed using the anatomic approach under fluoroscopic guidance. The most common successfully ablated region was the midseptal region (25 of 50, 50%). Slow pathway (SP) ablation and SP modulation were performed in 43 and 6 patients, respectively. Complication occurred in 1 patient with complete atrioventricular block. During follow-up, 6 patients had recurrence of supraventricular tachycardia, as confirmed by electrocardiography. Among them, 5 underwent successful ablation at the first procedure. In 1 patient, induction failed during the first procedure. Conclusion: RFCA is safe and effective in pediatric AVNRT patients. However, further research is needed for establishing the endpoints of ablation in pediatric AVNRT patients and for identifying risk factors by evaluating data on AVNRT recurrence after RFCA.

Mid-Term Results of Totally Thoracoscopic Ablation in Patients with Recurrent Atrial Fibrillation after Catheter Ablation

  • Lim, Suk Kyung;Kim, Joo Yeon;On, Young Keun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.270-276
    • /
    • 2020
  • Background: We investigated the impact of previous catheter ablation (CA) on the midterm outcomes of totally thoracoscopic ablation in patients with lone atrial fibrillation (AF). Methods: Between February 2012 and July 2018, 332 patients underwent totally thoracoscopic ablation for the treatment of AF (persistent AF; n=264, 80%). The patients were stratified into CA (n=47, 14%) and non-CA (nCA; n=285, 86%) groups according to their CA history. Results: All the baseline clinical characteristics and risk factors were similar between the groups except for age, percentage of male patients, prevalence of paroxysmal AF, prior percutaneous coronary intervention, and left atrial volume index (LAVI). No significant intergroup differences were observed in the incidence of early and late complications. At late follow-up, normal sinus rhythm was observed in 92% (43 of 47) of the patients in the CA group and 85% (242 of 285) of the patients in the nCA group (p=0.268). The rate of freedom from AF recurrence at 5 years was 55.3%±11.0% in the CA group, which was similar to that in the nCA group (55.7%±5.1%, p=0.690). In Cox regression analysis, preoperative brain natriuretic peptide levels and LAVI were associated with AF recurrence, but CA history was not significant. Conclusion: Totally thoracoscopic ablation was safe and effective in treating AF irrespective of CA history. A history of CA did not appear to affect the procedural complexity.

Theoretical Modeling of Pulsed Plasma Thruster Performance with Teflon Ablation

  • Cho, Mingyoung;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권1호
    • /
    • pp.138-143
    • /
    • 2017
  • A performance analysis for a pulsed plasma thruster(PPT) has been conducted to predict the thrust and current change. Two models were implemented - a one-dimensional lumped circuit analysis model and the Teflon ablation model provided by Michael Keidar. The circuit model incorporating resistance and inductance models was adapted to predict the magnitude of the discharge current. Numerical simulations like current discharge rates with different voltages were reasonably well compared with experimental data. The effects of Teflon ablation on thruster characteristics were investigated.