• 제목/요약/키워드: Abdominal ultrasound

검색결과 233건 처리시간 0.026초

The changes of rectus abdominis muscle thickness according to the angle during active straight leg raise

  • Lee, Hwang Jae;Shin, Kil Ho;Byun, Sung Mi;Jeong, Hyeon Seo;Hong, Ji Su;Jeong, Su Ji;Lee, Wan Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제2권1호
    • /
    • pp.44-48
    • /
    • 2013
  • Objective: The purpose of this study was to investigate changes of abdominal muscles thickness according to the angle during the active straight leg raise (ASLR) in young healthy subjects. Design: Cross sectional study. Methods: Twenty-three healthy university students (13 men and 10 women) voluntary participated to the study in S University. The ASLR was performed with the subject lying supine with lower extremities straight on a standard plinth, hands resting on the chest, and elbows on the plinth. When one subject performed ASLR from each angles ($30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$), compared changes in the thickness of rectus abdominis muscle. Changes in muscle thickness during ASLR test were assessed with ultrasonography. All subjects were to provide enough time of rest after performed ASLR. Rectus abdominis thickness were measured using rehabilitative ultrasound image. Results: Good quality rectus abdominal muscle activation data were recorded during ASLR. The length changes of linea alba showed significantly shorter in between $0^{\circ}$ and $30^{\circ}$ (p<0.05). The thickness of rectus abdominis muscle were significantly different between $0^{\circ}$ and $30^{\circ}$, $0^{\circ}$ and $45^{\circ}$, $0^{\circ}$ and $60^{\circ}$, $0^{\circ}$ and $90^{\circ}$. According to increase of pelvic angle, the thickness of rectus abdominis muscle were more thickening (p<0.05). Conclusions: This result is changes of abdominal muscles thickness according to the angle during the ASLR.

  • PDF

Diagnostic values of abdominal muscles thickness and sterno-costal angle for young adults with rounded shoulders

  • Lee, Chan-hee;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권1호
    • /
    • pp.49-54
    • /
    • 2020
  • Objective: The purposes of this study was to evaluate the diagnostic values of abdominal muscles thickness and sterno-costal angle as the quantitative diagnostic indicators for young adults with rounded shoulders. Design: A observational, cross-sectional study. Methods: This study included thirty-three male participants in order to examine the relationship among thoracic kyphosis, sternocostal angle, and abdominal muscle thickness. We used ultrasound imaging to measure the muscle thickness, two gravity-dependent inclinometers to measure the kyphosis angle, and Image J to measure the sterno-costal angle. Results: There was a significant positive correlation between the amount of thoracic kyphosis angle and muscle thickness of the external oblique (EO) on the right side (r=0.931), and on the left side (r=0.432), and the transverse abdominis (TrA) (r=0.649). There was also a significant negative correlation between the thoracic kyphosis angle and the sterno-costal angle at the right side (r=-0.942) and at the left side (r=-0.860). There was a significant positive relationship with muscle thickness of the EO and TrA on the right side with the thoracic kyphosis angle, and was significant negative relationship with the sterno-costal angle on both sides. Conclusions: The results of the study suggest that the thoracic kyphosis angle is related to muscle thickness of the EO and TrA on the dominant side and the sterno-costal angle. We also suggest that future studies are needed to determine how strengthening the abdominal muscles may contribute to preventing excessive thoracic kyphosis in young adults.

Abdominal skin subcutaneous fat thickness over the gestational period in Korean pregnant women: a descriptive observational study

  • Hwang, Moon Sook
    • 여성건강간호학회지
    • /
    • 제27권4호
    • /
    • pp.318-325
    • /
    • 2021
  • Purpose: Although insulin is usually injected into the abdominal subcutaneous fat, in pregnancy women tend to avoid abdominal injections due to concern about fetal damage. Prior studies have been limited to only measuring skin-subcutaneous fat thickness (S-ScFT) at one site at specific pregnancy points. This study aimed to measure S-ScFT across several abdominal sites and over the gestational period in Korean pregnant women. This can identify which site would be relatively safe for subcutaneous injection during pregnancy. Methods: Healthy women over 24 weeks of pregnancy in Korea were invited to voluntarily participate in this descriptive study. For the 142 women, S-ScFT of 12 sites in the abdomen were measured by ultrasound, several times over the pregnancy. Each incidence was treated as a case and a total of 262 cases were analyzed. Results: The mean S-ScFT during pregnancy was 1.14±0.47 cm (1.25±0.54 cm at 24+0-27+6 weeks; 1.17±0.48 cm at 28+0-31+6 weeks; 1.09+0.40 cm at 32+0-35+6 weeks; and 1.06±0.47 cm at 36+0-40 weeks of pregnancy). Most S-ScFT were thicker than 10 mm. But S-ScFTs in the lateral abdomen and some sites were suboptimal (<6 mm), especially in the pre-pregnancy underweight body mass index group, who had a high rate of suboptimal thickness (27.1% overall and 33.9% in the lateral side). Conclusion: The whole abdomen seems to be appropriate for subcutaneous injection in most Korean women during pregnancy, with a 4 to 5-mm short needle. However, for the lateral abdomen, making the skin fold might be needed for fetal safety.

스마트폰 애플리케이션을 이용한 골반바닥근육 운동이 배 근육 두께와 최대 자발적 환기량에 미치는 영향 (The Effect of Pelvic Floor Muscle Exercise Using a Smartphone Application on Abdominal Muscle Thickness and Maximum Voluntary Ventilation)

  • 박한규;이동규;박재철
    • 대한통합의학회지
    • /
    • 제11권3호
    • /
    • pp.1-10
    • /
    • 2023
  • Purpose : This study was conducted to determine the effect of intervention using a smartphone application on abdominal muscle thickness and maximum voluntary ventilation when conducting pelvic floor muscle exercise (PFME). Methods : This study was performed on 14 subjects. They were divided into two groups; PFME using smartphone application (n=7), common PFME (n=7). Both of group executed the exercise 5 times a week for 1 weeks. Abdominal muscle thickness was measured using ultrasound. Maximum voluntary ventilation was measured using a spirometer. The smartphone application used the paid version of Kegel trainer. This material was analyzed by the paired t-test to compare differences on each group and the independent t-test to compare between the two groups. Results : The PFME group using the smartphone application showed a significant increase in the transverse abdominis and internal oblique muscles (p<.05). The common PFME group showed a significant increase in the internal oblique muscle (p<.05). There was no significant difference in variation of the muscle thickness between the two groups (p>.05). The PFME group using the smartphone application showed a significant increase in the maximal voluntary ventilation (p<.05). There was no significant difference in variation of the maximal voluntary ventilation between the two groups (p>.05). Conclusion : As a results of this study, PFME using a smartphone application seems to induce voluntary participation of subjects and maintain continuity against time constraints. As a result, it is thought that using a smartphone application when performing PFME is efficient and convenient in terms of research method. However, this study is difficult to generalize due to the small number of subjects and short intervention period. Therefore, additional research should be conducted by modifying and supplementing these limitations.

코어운동이 마른 비만 여성의 신체조성과 복부 근육두께, 몸통 근지구력, 심리적 요인에 미치는 영향 (Effects of Core Exercise on Body Composition, Abdominal Muscle Thickness, Trunk Muscular Endurance, and Psychological Factors in Normal-weight Obese Women)

  • 김상호;서태화;이남기
    • 대한물리치료과학회지
    • /
    • 제30권3호
    • /
    • pp.72-83
    • /
    • 2023
  • Background: Normal-weight obese women have a normal weight with relatively low muscle mass resulting from high body fat. We aimed to investigate the effects of core exercise on body composition, abdominal muscle thickness, trunk muscular endurance, and psychological factors in normal-weight obese women. Design: One group pre-, mid-, and post-test design. Methods: A total of 20 normal-weight obese women were recruited voluntarily. Core exercises were performed for 30 minutes, three times a week for 4 weeks. InBody measurements, ultrasound imaging, and clinical tests were used to assess body composition, abdominal muscle thickness, trunk and core muscular endurance, and psychological condition(satisfaction with appearance and self-esteem). The dependent variables were measured three times: before the intervention (pre-test), 2 weeks after the intervention (mid-test), and 4 weeks after intervention (post-test). One-way repeated measures ANOVA and Friedman test were used for statistical analysis. Results: Although there was no change in the body composition (p>0.05), thickness of the transversus abdominis and internal and external oblique muscles, endurance of the trunk flexors and extensors and core muscles, and psychological condition showed significant differences after the intervention (p<0.05). Conclusion: Our findings will help develop exercise programs for normal-weight obese individuals that utilize the beneficial effect of core exercises.

한의 복합 치료로 호전된 난소 낭종 파열 1례 : 증례 보고 (A Improved Case Report of Ruptured Ovarian Cyst Treated by Korean Medicine Treatment)

  • 이희윤;황수인;윤영진;박장경
    • 대한한방부인과학회지
    • /
    • 제34권4호
    • /
    • pp.175-184
    • /
    • 2021
  • Objectives: The purpose of this study is to report the clinical effectiveness of Korean medicine treatment on ruptured ovarian cyst. Methods: The patient diagnosed with ruptured ovarian cyst was treated with Korean medicine treatment during 10 days of hospitalization. The patient received Korean medicine treatment including herbal medicine, acupuncture and moxibustion. The effect of treatment on ruptured ovarian cyst was evaluated through the Numeric Rating Scale (NRS) and Ultrasound. Result: After the treatment, the clinical symptoms of abdominal pain and fatigue were improved. Also, on transvaginal ultrasound, bleeding was almost absorbed. Conclusions: This case report proved that the Korean medicine treatment may be effective for improving clinical symptoms after ovarian cyst ruptured. However, further clinical study is needed in the furture to prove the effectiveness of Korean medicine treatment for ruptured ovarian cyst.

비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향 (Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance)

  • 이동우;정모범
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

Effect of Vibration Exercise Application on the Trunk Muscle Thickness in Children with Spastic Cerebral Palsy

  • Mun, Dal-Ju;Park, Jae-Chul;Oh, Hyun-Ju
    • The Journal of Korean Physical Therapy
    • /
    • 제34권2호
    • /
    • pp.68-72
    • /
    • 2022
  • Purpose: This study examined the effect of vibration exercise on the thickness of the oblique extrinsic, oblique abdominal, and biceps muscles, which are trunk muscles, targeting children with spastic cerebral palsy. Methods: The participants in this study were 20 children (8 male and 12 female) with cerebral palsy aged 5-10 years. They were classified into two groups using a randomized allocation method, and the trunk muscle thickness was measured using an ultrasound-imaging device before and six weeks after the experiment. A paired t-test was used for the within-group changes, and an independent t-test was used for the inter-group changes. The significance level was set to α=0.05. Results: There was a significant increase in the inter-group change in the experimental group and control group in the intra-group change in the external oblique muscle and internal oblique muscle. After six weeks, there was a significant increase in the experimental group compared to the control group. Conclusion: Vibration exercise had a positive effect on the trunk muscle thickness of children with cerebral palsy. Vibration exercise produced a significant difference in the changes in the trunk muscle thickness in children with cerebral palsy compared to no vibration exercise. These results may provide basic data for future research and as a training method for strengthening the trunk muscles in clinical trials.

거대적혈모구빈혈을 동반한 알코올 간염 환자에 대한 한의치료 치험 1례 (A Case Report of Alcoholic Hepatitis with Megaloblastic Anemia Treated with Korean Medicine)

  • 김채은;선승호;백태현;한승희
    • 대한한방내과학회지
    • /
    • 제45권3호
    • /
    • pp.444-455
    • /
    • 2024
  • Objectives: This study aimed to report a case of alcoholic hepatitis with megaloblastic anemia that improved with Korean medicine treatment. Methods: A 27-year-old woman with alcoholic hepatitis and megaloblastic anemia was treated with herbal medicine, acupuncture, and moxibustion. The responses before and after treatment were evaluated using blood tests, ultrasound imaging, the Checklist Individual Strength (CIS), and the numerical rating scale (NRS). Results: Post-treatment, blood tests showed improved liver function test, lipid test, and anemia work-up. Ultrasound imaging showed improvement in the superoinferior diameter of right lobe, from 13.02 to 11.09, and the fatty liver improved. The CIS score decreased from 107 to 55. Fatigue diminished from NRS 10 to NRS 3, and dizziness dropped from NRS 5 to NRS 1. The abdominal distension slightly decreased, from NRS 7 to NRS 5. Conclusion: Korean medicine treatment might be effective for treating alcoholic hepatitis with megaloblastic anemia.

Screening in the Era of Economic Crisis: Misperceptions and Misuse from a Longitudinal Study on Greek Women Undergoing Benign Vacuum-assisted Breast Biopsy

  • Domeyer, Philip John;Sergentanis, Theodoros Nikolaos;Katsari, Vasiliki;Souliotis, Kyriakos;Mariolis, Anargiros;Zagouri, Flora;Zografos, George Constantine
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5023-5029
    • /
    • 2013
  • Background: To evaluate knowledge about screening tests and tests without proven screening value in a Greek Breast Unit population undergoing benign vacuum-assisted breast biopsy (VABB). Materials and Methods: This study included 81 patients. Three knowledge-oriented items (recommended or not, screening frequency, age of onset) were assessed. Regarding screening tests two levels of knowledge were evaluated: i). crude knowledge (CK), i.e. knowledge that the test is recommended and ii). advanced knowledge (AK), i.e. correct response to all three knowledge-oriented items. Solely CK was evaluated for tests without proven screening value. Risk factors for lack of knowledge were assessed with multivariate logistic regression. A second questionnaire was administered 18 months after VABB to assess its impact on the performance of tests. Results: Concerning screening tests considerable lack of AK was noted (mammogram, 60.5%; Pap smear, 59.3%; fecal occult blood testing, 93.8%; sigmoidoscopy, 95.1%). Similarly lack of CK was documented regarding tests without proven screening value (breast self-examination, 92.6%; breast MRI, 60.5%; abdominal ultrasound, 71.6%; barium meal, 48.1%; urine analysis, 90.1%; chest X-Ray, 69.1%; electrocardiogram, 74.1%; cardiac ultrasound, 75.3%). Risk factors for lack of AK were: place of residence (mammogram), age (Pap smear), personal income (sigmoidoscopy); risk factors for lack of CK included number of offspring (breast MRI, chest X-Ray), BMI (abdominal ultrasound), marital status (urine analysis), current smoking status (electrocardiogram). VABB's only effect was improvement in mammogram rates. Conclusions: A considerable lack of knowledge concerning screening tests and misperceptions regarding those without proven value was documented.