• Title/Summary/Keyword: Abdominal radiography

Search Result 159, Processing Time 0.025 seconds

Sick Sinus Syndrome (SSS) in a Maltese Dog Concurrent with Mitral Valve Endocardiosis (MVE) (말티즈견에서 발생한 Mitral Valve Endocardiosis (MVE)를 동반한 Sick Sinus Syndrome (SSS)에 대한 증례)

  • Park Chul;Jung Dong-in;Kim Ha-Jung;Kang Byeong-Teck;Kim Ju-Won;Lim Chae-Young;Yoo Jong-Hyun;Park Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.396-400
    • /
    • 2005
  • A 13-year old, female Maltese dog was presented due to a five-month history of episodic syncope. A diagnosis of sick sinus syndrome (SSS) with mitral valve endocardiosis (MVE) was made based on history takings, physical and cardiac examination, complete blood count (CBC), serum chemistry profiles, radiography, electrocardiography (ECG), atropine response test, hormonal assay, and echocardiography. In this case, SSS was definitely diagnosed by evaluation of ECG recording following atropine administration. Clinical signs were improved with medical management of theophylline (THEOLAN, KunWha Pharm, Seoul, Korea, 20 mg/kg, PO, BID). After 10 more month survival, the dog, died of respiratory distress and shock during the operation of abdominal mass removal in local animal hospital. Unfortunately, we were not able to perform necropsy after death due to owner's decline. This case demonstrates that theophylline can be used in management oF dog with SSS.

Intestinal Lymphangiectasia in a Yorkshire terrier Dog: Clinical Outcome, Clinicopathological and Histopathological Findings (요크셔테리어견에서 발생한 Intestinal Lymphangiectasia: 임상적 결과와 임상병리학적, 조직병리학적 소견)

  • Hwang Du-Na;Park Chul;Kang Byeong-Teck;Jeong Soon-Wuk;Sur Jung-Hyang;Park Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.175-179
    • /
    • 2006
  • A 7-year-old, 3.16 kg intact male Yorkshire terrier had the history of abdominal distension, diarrhea, and weight loss. On the basis of history takings, physical examination, laboratory tests, radiography, ultrasonography, exploratory laparotomy, and histopathological examination, the dog was diagnosed definitely as intestinal lymphangiectasia. In this case, signs and results are consistent with those of other reports, but some clinicopathological findings such as hypocalcemia and hypocholesterolemia are not. This means that the findings were not completely in accord with the typical ones of intestinal lymphangiectasia in this dog. Prednisolone was prescribed to treat. However, it was not effective sufficiently. Thus, azathioprine was added to the regimen used in the first trial, and it was quite efficient in inducing remission in intestinal lymphangiectasia. The clinical signs were improved to the combined therapy. This case report demonstrates that the combined therapy for intestinal lymphangiectasia can be used as an alternative to only glucocorticoid therapy.

Emergency preoperative angioembolization without computed tomography to treat unstable pelvic fractures with bowel perforation (장 천공을 동반한 혈역학적으로 불안정한 골반골 골절에서 전산화 단층촬영 전 시행한 혈관색전술의 지혈효과: 증례보고)

  • Park, Chan-Yong;Kang, Wu-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.417-422
    • /
    • 2019
  • Hemodynamically unstable pelvic fractures show a remarkably high mortality rate of 40% to 60%. However, their standard of care remains controversial. We report here a case of a 78-year-old woman who was admitted to the Emergency Department with pelvic pain following a fall. Based on pelvic radiography, she was diagnosed with an unstable pelvic fracture. Her blood pressure was 60/40 mmHg, and owing to her unstable vital signs, emergency angiography was performed without computed tomography (CT). Both internal iliac arteries were embolized without sub-branch selection for prompt control of pelvic bleeding. Following embolization, her vital signs were stabilized. Subsequent CT revealed free intra-abdominal air, suggesting bowel perforation had occurred and necessitating emergency laparotomy. An approximately 1 cm-sized free perforation of the small intestine was identified intraoperatively, and primary closure was performed. A retroperitoneal hematoma identified intraoperatively was not explored further because it was a non-expanding and non-pulsatile mass. The patient was admitted to the Intensive Care Unit and transferred to the general ward on postoperative day 3. In this case, the hemodynamically stable pelvic fracture with bowel perforation was successfully and safely treated by prompt angioembolization without conducting CT.

COVID-19 in a 16-Year-Old Adolescent With Mucopolysaccharidosis Type II: Case Report and Review of Literature

  • Park, So Yun;Kim, Heung Sik;Chu, Mi Ae;Chung, Myeong-Hee;Kang, Seokjin
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.2
    • /
    • pp.70-76
    • /
    • 2022
  • Coronavirus disease 2019 (COVID-19) in patients with underlying diseases, is associated with high infection and mortality rates, which may result in acute respiratory distress syndrome and death. Mucopolysaccharidosis (MPS) type II is a progressive metabolic disorder that stems from cellular accumulation of the glycosaminoglycans, heparan, and dermatan sulfate. Upper and lower airway obstruction and restrictive pulmonary diseases are common complaints of patients with MPS, and respiratory infections of bacterial or viral origin could result in fatal outcomes. We report a case of COVID-19 in a 16-year-old adolescent with MPS type II, who had been treated with idursulfase since 5 years of age. Prior to infection, the patient's clinical history included developmental delays, abdominal distension, snoring, and facial dysmorphism. His primary complaints at the time of admission included rhinorrhea, cough, and sputum without fever or increased oxygen demand. His heart rate, respiratory rate, and oxygen saturation were within the normal biological reference intervals, and chest radiography revealed no signs of pneumonia. Consequently, supportive therapy and quarantine were recommended. The patient experienced an uneventful course of COVID-19 despite underlying MPS type II, which may be the result of an unfavorable host cell environment and changes in expression patterns of proteins involved in interactions with viral proteins. Moreover, elevated serum heparan sulfate in patients with MPS may compete with cell surface heparan sulfate, which is essential for successful interaction between the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein and the host cell surface, thereby protecting against intracellular penetration by SARS-CoV-2.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Hepatic Cirrhosis Secondary to chronic Hepatitis in an English Cocker Spaniel (ECS) Dog (잉글리쉬 코커스파니엘 견에서 발생한 만성 간염 및 간경화 증례)

  • Park Chul;Yoo Jong-Hyun;Jung Dong-In;Kim Ha-Jung;Kang Byeong-Teck;Lim Chae-Young;Yoon Hun-Young;Jeong Soon-Wuk;Sur Jung-Hyang;Park Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.72-76
    • /
    • 2006
  • A 1-year-old, female English cocker spaniel (ECS) dog was presented with 3-month history of vomiting and retaking of the vomitus, and chronic weight loss. The client had noticed mild abdominal distension 10 days before. The dog was diagnosed as chronic hepatitis with hepatic cirrhosis based on complete blood count (CBC), serum chemistry profiles, radiography, ascites assessment, bile acid evaluation, and liver biopsy through exploratory laparotomy and necropsy. CBC and serum chemistry profiles revealed mild anemia, slightly elevated hepatic enzymes (ALT and AST), increased creatinine kinase (CK), hyperammonemia, and hypoproteinemia with hypoalbuminemia. Ascites was transudate according to analysis of components. Bile acid assessment (fasting; $174.4{\mu}mol/L$ and postprandial; $198.4{\mu}mol/L$) showed strongly suspected hepatic insufficiency. On radiological findings, ascites was evident. Atrophied liver (especially left side lobes) and distended mesenteric vasculatures were observed by exploratory laparotomy. Histopathological examination of marginal lesion of left lateral lobe of liver by biopsy revealed the necrosis of hepatic cells, dilation of sinusoids, infiltration of neutrophils in sinusoids, and vacuolation of hepatic cytoplasm. The patient had been managed with careful low protein diet and specific supportive therapy (ursodeoxycholic acid, prednisolone, vitamine E, and interferon). Vomiting and ascites disappeared with medical management. The dog was monitored periodically by CBC, serum chemistry and radiographic examination. The dog survived more 18 months with medical therapy. After spontaneous death, necropsy and histopathologic examination were performed.

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.