• 제목/요약/키워드: Abdominal X-ray radiography

검색결과 12건 처리시간 0.021초

영유아 및 소아의 단순복부 X-선 사진 (Plain Abdominal Radiography in Infants and Children)

  • 이희정
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제14권2호
    • /
    • pp.130-136
    • /
    • 2011
  • Plain X-ray radiographs are the first line of investigation taken in the diagnosis of abdominal pathology and are considered an important diagnostic tool to provide guidelines for further imaging studies and comprehensive therapeutic management. Although most abdominal pathology demonstrates non-specific radiologic findings, the plain abdominal radiography is very useful in specific diseases, including certain gastrointestinal anomalies. This review provides image findings of normal plain abdominal radiography and some common abdominal pathology in infants and children.

자동노출제어를 이용한 복부 일반 X선 검사에서 체질량지수가 입사표면공기커마에 미치는 영향 (The Effect of Body Mass Index on Entrance Surface Air Kerma in Abdominal X-ray Radiography Using Automatic Exposure Control)

  • 구노현;윤희수;최관우;이종은;김정진
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.659-667
    • /
    • 2018
  • 본 연구는 자동노출제어 (AEC; Automatic Exposure Control)를 이용한 복부 일반 X선 검사에서 체질량지수 (BMI; Body Mass Index)가 입사표면공기커마 (ESAK; Entrance Surface Air Kerma)에 미치는 영향에 대해 알아보았다. 연구방법은 AEC를 이용하여 복부 일반 X선 검사를 시행 받은 321명을 대상으로 키, 몸무게, BMI와 ESAK의 관계 및 BMI범주 (Underweight, Normal, Overweight, Obese 1, Obese 2)에 따른 평균 ESAK값을 비교하였다. 연구의 결과 몸무게 ($R^2=0.777$, p<.001)와 BMI ($R^2=0.835$, p<.001)는 ESAK와 양의 상관관계가 있었던 반면, 키 ($R^2=0.075$, p<.001)와 BMI는 뚜렷한 상관관계를 확인할 수 없었다. BMI범주에 대한 평균 ESAK는 통계적으로 유의한 차이를 보였으며, 사후분석을 통해 유의수준 0.05에 대해 5개의 부집단이 존재하여 모든 BMI범주 간 ESAK값의 차이가 있는 것을 알 수 있었다. 또한, 인접한 BMI간 ESAK값 증가폭이 Underweight에서 Obese 2로 갈수록 점차 늘어나 BMI가 증가할수록 피폭선량이 급격하게 증가되는 것을 알 수 있었다. 따라서 복부 일반 X선 검사에서 AEC를 사용할 경우 BMI가 증가함에 따라 과도한 선량이 조사될 수 있음을 인식하고 검사조건을 고정하여 촬영하는 등의 노력을 통한 선량저감화가 필요할 것으로 판단된다.

소아 장중첩증에서 증상 지속 시간에 따른 단순 복부 사진의 변화 (The Changing pattern of the Plain Abdominal Radiogram by Progression of the Intussusception in Children)

  • 전형석;최영철;최승호
    • Advances in pediatric surgery
    • /
    • 제15권2호
    • /
    • pp.132-140
    • /
    • 2009
  • The purpose of this study was to determine the success rate of air reduction as the primary treatment of intussusception and whether the success of air reduction could be predicted by plain x-ray. The authors reviewed the medical records of 54 consecutive patients diagnosed with intussusception from Jan 2005 to Dec 2007 at the Department of Surgery, Masan Samsung Hospital. The natures of symptoms and findings of plain abdominal radiography performed in the emergency department (ED) were reviewed. Air reduction failed more frequently (26.3 %) in patients who visited ED more than 24 hours after symptom onset (p=0.009). The mean duration of symptom for operated patients was longer than air reduction group (p=0.01). Also, 3/4 of patients having localized distension of small bowel in the left upper quadrant abdomen had unsuccessful air reduction (p=0.002). In conclusion, the time interval from symptom onset to arrival at ED and localized distension of small bowel in the left upper quadrant abdomen significantly increased the failure rate of air reduction.

  • PDF

복부 방사선검사 자세가 유방선량에 미치는 영향 (Effects of Breast Dose on Plain Abdominal Position)

  • 주영철;김승혁
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Balloon dilation with triamcinolone intralesional injection successfully treated rectal stricture in a three-month kitten

  • Lee, Hee-Ryung;Adam, Gareeballah Osman;Lee, Sei-Jin;Kim, Shang-Jin
    • 대한수의학회지
    • /
    • 제60권1호
    • /
    • pp.39-42
    • /
    • 2020
  • This report describes a three-month-old Korean domestic kitten presented with dehydration and poor body condition. Physical examination revealed abdominal distension. Rectal diagnosis was unachievable due to the small rectum diameter. X-ray radiography and endoscopy confirmed presence of abdominal distension and indicated a stricture located 1.5 cm from the anus. A balloon was gently inserted into the rectum and inflated several times followed by triamcinolone injection. Four months later, same procedures were repeated. This report is the first to describe the use of balloon dilation of a rectal stricture followed by intralesional triamcinolone injection in a small cat with poor condition.

소동물 X-선 진단에 있어서 광범위 관용도 필림의 이용에 관하여 (Application of Wide Latitude Film to Radiographic Diagnosis in Small Animal)

  • 최민철
    • 한국임상수의학회지
    • /
    • 제9권2호
    • /
    • pp.473-481
    • /
    • 1992
  • To elucidate the applicability of the wide latitude X-ray film for radiographic diagnosis and treatment of diseases in small animals, the quality of the wide latitude film was compared with that of the standard latitude film which is commonly used in veterinary clinic. The images of head, neck, thorax, abdomen, extremities and joints were radiographed with the wide latitude and standard latitude film in fourteen dogs. In soft tissues such as abdominal organs, lung, skin, mammary glands, the clearer and higher contrast of the image was observed on the wide latitude film. And these advantages were more apparent in pneumoeritoneography. Therefore. it can be suggested that the wide latitude film is practically useful for the evaluation of the images of soft tissues, and also can be used on hard tissue radiography with the same quality as the standard latitude film.

  • PDF

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

다각도 방사선촬영 및 투시법을 이용한 정상 고양이 장기의 형태학적 연구 (Morphological study on abdominal organs of healthy cats using omnidirectional radiography and fluoroscopy)

  • 신사경;히로세 츠네오;사토 모토요시;미아하라 카쯔노
    • 대한수의학회지
    • /
    • 제36권4호
    • /
    • pp.949-966
    • /
    • 1996
  • 형태학적으로 가장 효과적인 X-선 촬영 및 투시각도를 연구하기 위해서 전방향 방호X-선기와 소동물용 $360^{\circ}$ 회전형 보정장치를 이용하여 고양이의 복부장기를 대상으로 방사선 투시와 촬영을 병행하여 조사하였다. 조사한 장기는 횡격막, 간, 위, 결장, 비장, 신장이였다. 본 연구에서 얻어진 결과는 다음과 같다. 1. 횡격막은 $30^{\circ}$에서 $90^{\circ}$ 각도 사이에서 가장 선명한 결과를 얻을 수 있었다. 2. 간의 좌엽과 중간엽은 수평면의 $60^{\circ}$ 각도에서 관찰된 반면, 우엽은 수직면의 $60^{\circ}$ 각도에서 관찰되었다. 3. 위는 우측 $30^{\circ}$ 각도 복-좌배사면과 좌측 $60^{\circ}$ 각도 배-우복사면에서 가스가 존재할 때 특히 잘 관찰되었다. 4. 결장은 수평면의 $30^{\circ}$ 각도 이상에서는 자세히 관찰되었다. 5. 비장은 복배면과 우측 $60^{\circ}$ 복-좌배사면사이와 배복면과 좌-우외측면 사이의 각도에서 잘 관찰되었다. 6. 신장의 배쪽면과 등쪽면의 경우 수평면의 $30^{\circ}$ 각도에서 가장 잘 관찰되었다. 7. 이상의 결과를 종합해 볼 때 본 연구의 결과는 고양이 각 장기의 이상유무 분석에 유용하게 사용될 것으로 판단되었다.

  • PDF

소아복부 종괴의 방사선학적 고찰 (Radiologic Evaluation of Intraabdomenal Masses in Childhood)

  • 권혁포;변우목;황미수;김선용;장재천;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 1988
  • 최근 5년간의 소아의 복부종괴 23예를 발생빈도, 부위 및 방사선학적 소견을 중심으로 비교분석하여 다음과 같은 결론을 얻었다. 1. 전체 23예중 신경아세포종이 6예로 가장 많았고 그 다음이 Wilms 종양 5예, 담도낭종, 난소종양, 수신종 등의 순위였다. 2. 발생연령별로 분석해 본 결과 6세 이하가 78%(14예)를 차지했고 특히 후복강 종양은 6세 이하에 집중되어 있었다. 3. 부위별로는 후복강 종양이 60%(14예)로 가장 많았다. 4. 방사선학적 소견을 분석하여 본 결과 1) 단순 복부촬영상 신경아세포종의 50%에서 특징적인 석회와 음영을 볼 수 있었고 후복강 종양의 대부분에서 비특이적인 석회화 음영을 볼 수 있었다. 2) 초음파 소견상 저에코, 고에코 또는 혼합에코 등의 종괴 내부성상을 알 수 있었으나 종괴의 정확한 해부학적 위치를 파악할 수 없는 경우가 많았다. 3) 경정맥 신우 조영촬영상 신우신배의 비정상적인 소견과 신장의 전위 소견으로부터 신장내 종양과 신장의 다른 부위의 종양을 구분할 수 있었다. 4) 전산화 단층촬영상 종괴 내부의 성상뿐만 아니라 종괴의 해부학적인 위치, 주위 구조와의 관계, 임파절이나 다른 부위로의 전이유무를 알 수 있었다.

  • PDF

복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석 (The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen)

  • 손상혁;송영근;김제봉
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-43
    • /
    • 2007
  • I. 목적 : 본 연구에서는 복부의 이상적 영상 구현을 위한 Film Screen (F.S) System과 Computed Radiography(C.R) System의 촬영조건의 차이를 비교 분석해 보고, C.R system에서 촬영조건 변화에 따른 영상의 특성을 분석함으로써, C.R 환경에서 촬영조건 설정의 중요성을 살펴보고자 한다. II. 대상 및 방법 : F.S system에서 촬영 조건을 70kVp로 고정시키고, mAs를 단계적으로 변화시켜 복부 단순겸사를 시행하여 영상을 획득한 후, 진단방사선과 전문의와 방사선사로 구성된 영상평가 팀의 정량적, 정성적 분석을 통하여 F.S system 최적의 영상을 선정하였다. 동일 환자를 대상으로 C.R system 에서 위와 동일한 방법으로 영상을 획득한 후, F.S system과 C.R system의 영상의 특성곡선(Characteristic Curves)을 비교분석하고, C.R system에서 촬영조건 변화에 따른 복부 장기의 농도변화 및 영상의 특정을 비교 평가하였다. 마지막으로, F.S system과 C.R system의 최적의 영상 획득을 위한 촬영조건의 차이를 비교 분석하고, C.R 환경에서 촬영조건의 중요성을 살펴보았다. III. 결과 : F.S system에서 영상평가팀의 평가를 통하여 선택된 최적 영상의 촬영 조건은 70kVp, 20mAs로 나타났다. C.R system에서는 촬영조건 12mAs, 70kVp에서 복벽과 직접노출구역의 농도 차이가 최대인, 진단적 가치가 높은 영상을 얻을 수 있었다. C.R system에서는 (70kVp로 고정)변화한 mAs량(3.2mAs, 8mAs, 12mAs, 16mAs, 20mAs)에 상관없이 복부 장기는 거의 통일한 농도를 나타냈으며 12mAs 기준으로 노출 조건의 감소 또는 증가에 따라서 복벽과 직접노출부분의 명확한 구분이 불가능하였으며, mAs량이 낮아질수록 양자반점(Quantum Mottle)으로 인한 artifact는 증가함을 볼 수 있었다. IV. 결론 : 위의 실험 결과 본원 system의 복부단순검사에서는 C.R system 사용 시 F.S system 보다 촬영 조건을 약 40% 감소시킬 수 있었다. C.R환경에서 x-ray장치 Image processing 장치, 자동 감도조절(EDR : exposure data recognition processing) 장치, PACS 등 사용하는 장비들의 특성을 분석하여 적정 노출조건을 재설정한다면, 최소의 피폭선량으로 최대의 영상정보를 지닌 진단적 가치가 높은 영상의 획득이 가능하다고 사료된다.

  • PDF