• Title/Summary/Keyword: Abdominal Impedance

Search Result 31, Processing Time 0.041 seconds

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method (생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정)

  • Kim, Keo-Sik;Lee, Sang-Ok;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

Novel Impedance Method for Analyzing Truncal Obesity (중심성 비만 분석을 위한 새로운 임피던스 해석법)

  • Lim, Taek-Gyun;Seo, Kwang-Seok;Jeong, In-Cheol;Jun, Suk-Hwan;Noh, Yeon-Sik;Kim, Eung-Seok;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.849-856
    • /
    • 2009
  • Truncal obesity associated with insulin resistance and metabolic syndrome increase the likelihood of hypertension, various cardiovascular diseases, hyperlipidemia and coronary heart diseases. International Diabetes Federation (IDF) experts recognized that it is necessary to develop the simple diagnostic tool which is applicable to diagnose truncal obesity worldwide, and proposed the method using a waist circumference but there is a limit to estimate subcutaneous fat distribution. However, waist line is also influenced by total fat capacity less than the intra abdominal fat. The more having severe obesity, the more correlation coefficient between waist line and intra abdominal fat is low. Therefore, this thesis defines a new abdominal impedance measurement position and impedance-index to analysis central obesity. This proposes the new model to estimate abdominal obesity using the abdominal impedance-index and CT images acquired fro 160 Korean subjects. The proposed model shows that the abdominal fat distribution has a higher correlation than waist line. (Adj R2=0.809, 0.667 and 0.687 with abdominal fat area, visceral fat area and subcutaneous fat area respectively).

A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System (요역동학 측정시스템을 위한 새로운 복압측정 기법)

  • Seo, Jeong-Hwan;Kim, Keo-Sik;An, Yang-Su;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity (소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구)

  • Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1082-1089
    • /
    • 2005
  • Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.

The Effects of Sobi-eum(Xiaofei-yin) Mesotherapy on Abdominal Fat Distribution (소비음을 이용한 경피침주요법이 복부비만에 미치는 영향에 대한 임상연구)

  • Lee, A-Ra;Cho, Yu-Jung;Jung, Won-Suk;Yang, Yu-Jung;Song, Mi-Yeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.261-273
    • /
    • 2009
  • Objectives : This study was performed to figure out the effects of herbal mesotherapy on abdominal fat in obese women. Methods : Forty obese women those who were diagnosed abdominal obesity had been recruited during February, 2008. They were randomly assigned experimental or control group under block-randomization. Experimental group were treated with Sobi-eum(Xiaofei-yin) injection during 6 weeks (2 times a week) and placebo group were treated with normal saline injection under same procedures. Anthropometry, body impedance analysis, fat computed tomography, blood test, and questionnaires had been administered before and after the treatment. Results : Four subjects were dropped out (voluntary give up), so 18 in experimental group and 18 in placebo group were evaluated. There were significant changes after treatments in both groups. Although no significant differences have been found in the result of anthropometry, body impedance analysis and fat computed tomography between two groups, in the experimental group, the changes of total fat area had a highly significant relationship with all part of abdominal fat. While the placebo group had highly significant relationships with subcutaneous fat area, superficial and deep subcutaneous fat area but not with visceral fat area. Conclusions : Compaired with saline group, herbal mesotheraphy Sobi-eum(Xiaofei-yin) is effective in reduction of visceral fat after adjusting TFA.

The Research about Distribution of Abdominal Fat in Obese Premenopausal Korean Women (폐경전 한국인 비만여성에서 복부 지방의 분획별 특성에 대한 임상연구)

  • Lee, A-Ra;Chung, Won-Suk;Song, Mi-Yeon
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.8 no.2
    • /
    • pp.25-35
    • /
    • 2008
  • Objectives This study was performed to find out the characters about distribution of abdominal fat(especially superficial and deep subcutaneous fat) in obese premenopausal Korean women. Methods 39 obese premenopausal women were recruited in 2008. Anthropometry and body impedance analysis have been done and abdominal fat distribution had been assessed by computed tomography scan at the level of L4-5. Blood test and questionnaires about depression, eating attitude and physical activity were underwent. Result Abdominal total fat area, subcutaneous fat area including superficial and deep were significantly correlated with anthropometry and BIA result while visceral fat was correlated only with age and waist circumference. In blood profile, only visceral fat area was correlated with HDL cholesterol and triglyceride. And there were no correlation among questionnaires and abdominal fat. There were no difference between superficial and deep subcutaneous fat. Conclusion Abdominal subcutaneous fat including superficial and deep did not have any correlation with heart risk factor. superficial and deep subcutaneous fat had no differences with each other and they did not show any correlation with visceral fat in obese perimenopausal Korean women.

  • PDF

A Study on the Percentage of Body Fat and Abdominal Obesity of Workers Using Bioelectrical Impedance Analysis (일개 사업장 근로자들의 한방건강검진에서 체성분검사를 통한 체지방률과 복부비만 결과 분석)

  • Park, Young-Sun;Kim, Jong-Dae
    • The Journal of Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.113-123
    • /
    • 2008
  • Objectives: Obesity is chronic condition which can severely influence health. People with a high percentage of body fat (%BF) have high prevalence of hypertension and hypercholesterolemia. Abdominal obesity (AO) seems to play a major role in the development of cardiovascular disease, diabetes and hyperlipidemia. This study investigated the %BF and AO of workers in the automobile manufacturing industry. Methods: The subjects were categorized by sex, age, job class, drinking history and smoking history. %BF and AO were measured by using bioelectrical impedance analysis (Jawon Medical, Seoul, Korea). We analyzed the relationship between age, sex, job class, drinking history, smoking history and %BF and WHR into frequencies, $X^2$-test using the SPSS Ver. 12.0. Results: Regarding the relationship between sex and %BF, AO, there was statistically significant difference as men had a significant higher level of %BF and AO than women. There was a positive correlation between age and both %BF and AO. Workers in their 40s especially ran level of AO up. In job class, office workers were apt to have a higherlevel of %BF and AO than production line workers. %BF and AO of the non-drinker group showed a lower level than the drinker group. On the other hand, the ex-smoker group had higher levels of %BF and AO than the non-smoker or current-smoker groups. Conclusions: The above results showed that men, the advanced in years, office workers, drinkers and ex-smokers had high levels of %BF and AO.

  • PDF

Prediction of Suitable Site to Measure Abdominal Skin Fold Thickness and Correlation among Obesity Indicators in Patients with Type 2 Diabetes Mellitus (제2형 당뇨병 환자에서 피부두겹두께의 측정부위 예측 및 비만지표들 간의 관련성)

  • Hwang, Moon Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.22 no.1
    • /
    • pp.36-44
    • /
    • 2020
  • Purpose: The purpose of this study was to predict measuring site suited for abdominal skin fold thickness (ASFT) by measuring the distribution of abdominal subcutaneous fat thickness (AScFT) and ascertain the correlations among obesity indicators. Methods: The size of analysis materials was 124 secondary data measured by ultrasonic device, bioelectrical impedance analyzer and caliper. Data were analyzed using t-test, and Pearson's correlation. Results: The average of AScFT was 10.63± 6.79mm with its range 1.39-36.16 mm, and AScFT of female and of central parts were thicker than those of male and outer parts in the abdomen. The average of ASFT was 29.26±12.59 mm. Site 5 on Figure 1 was most similar to the average of AScFT in both sexes. Body mass index (BMI) and waist hip ratio (WHR) were 23.65±3.98 and 0.88±0.05 respectively. The body weight, BMI, WHR, visceral fat, ASFT vs AScFT revealed in significant correlation (r= .29, r= .55, r= .39, r= .33. r= .29). Conclusion: BMI and WHR seem more useful than other obesity indicators, when obesity control is necessary for Type 2 diabetes patients. Site 5 on Figure 1 is most suitable site to measure ASFT.

Usefulness of Abdominal Fat Measured by Computed Tomography and Bioelectric Impedance Analysis as an Obesity Index (컴퓨터단층촬영과 생체전기 저항 분석법으로 측정된 복부지방의 비만지표로서의 유용성)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.807-813
    • /
    • 2011
  • For obesity management requires accurate measurement of abdominal fat. The purpose of this study was to find out the correlation between abdominal fat and lipid measured with BIA and CT. Secondly, This study investigate for usefulness of abdominal fat measured by BIA and CT as an obesity index. As a result, TG showed higher value in the overweight obese group than normal group but HDL showed lower value in the overweight obese group than normal group. TG and HDL appeared significantly relationship with by BIA and CT in the normal group. However, in the overweight obese group TG showed significantly relationship with the BIA. According to multiple regression analysis on BMF and TAF was affected by HDL in the normal group. And BMF, %BF was affected by TG in overweight obese group. In conclusion, abdominal fat showed significant correlation with lipid. Abdominal fat measured by BIA and CT to assess obesity index is considered as a useful way to evaluate.